Chapter 6
Operating the display panel
- -
43
6-7
Displaying and setting data of high- and low-order digits
For numeric data of five or more digits, the high- and low-order digits are displayed separately.
No.
Description
Lower limit
Upper limit
Paramete
r
P00
Position error allowance
0
32767
d00
Feedback pulse count (display of 4 times
of encoder)
−
−
d01
Command pulse count (display of 4 times
of encoder)
−
−
Numeric
monitor
d02
Error pulse count (display of 4 times of
encoder)
−
−
Example: Displaying/changing parameter No. 00 = 30000
Display of high-order digits
Display of low-order digits
Note: The numeric monitor can only display a numeric value
without permitting you to change it.
:
:
Press the DATA key to display the
high-order digits.
Press the UP key to display the
high-order digits. Press the DOWN
key to display the low-order digits.
Press and hold down the DATA key for 1s or
longer. The most significant digit blinks to
indicate the change mode.
High-order digits
Changing the high-order digits
Low-order digits
Each time the DATA key is pressed, the
blink moves to the next lower digit.
Press the DATA key at the right end to
display the four lower digits.
Parameter No.
Changing the low-order digits
Press the DATA key at the least
significant digit to complete the change.
:
:
Lights up while the high-order digits are on display.
Lights up while the low-order digits are on display.