Chapter 4 Options
4-2 Brake for motor (option code: B)
FHA-C series actuators are possible to equip a brake on the motor shaft to hold its position during no power supply.
The brake of FHA-C series actuator provides two coils for activating and for holding respectively to decrease the current during holding by an
electric circuit in the actuator.
Use a DC power supply having proper output voltage and enough capacity for activating current presented in the table below.
4-2-1 Specifications for incremental encoder system
Model
FHA-17C
FHA-25C
FHA-32C
FHA-40C
Item
50 100 160
50 100 160
50 100 160
50 100 160
Type
Dry-type non-excitation electro-magnetic brake with activating coil and holding coil
Power
supply
V
DC24V +/-10%; no-polarity; note 1
Activating
current
(20
ºC);
note 2
A
1.0
1.1
1.2
1.3
Holding
current
(at 20 ºC)
A
0.15
0.15
0.2
0.25
Holding
torque;
N·m
24
49
78
49
98
157
75 150 240
108 216 345
note 3
kgf·m
2.5 5 8
5 10 16 7.7 15 24
11 22 35
Actuator
inertia
GD2/4)
0.24
0.96
2.5
1.0
4.1
10.6
2.1
8.4 22
5.5
22 57
converted for output
kg·m
2
flange;
note 3
(J)
2.4 9.8 25
10 42 110 21 86 220
56 230 580
kgf·cm·s
2
Mass of actuator;
note 4
kg
2.9
4.8 7.4
14
Service time for normal
100,000 times
holding;
note 5
Service time for
emergency
stop;
note 6
200 times
Note 1:
Power supply is user’s responsibility. Use a DC power supply having proper output voltage and enough capacity for activating
current presented in the table above.
Note 2:
The duration for activating current is less than 0.5 second for the power supply of DC24V±10%.
Note 3:
The values are converted for the output flange.
Note 4:
The values present total mass of the actuator.
Note 5:
The service time for normal holding is assured when the brake activates at motor speed of 150 r/min or less.
Note 6:
The service time for emergency stop is assured when the brake activates at motor speed of 3000 r/min or less.
Do not use the holding brake exceeding the service times for normal holding
(100,000 times at the motor speed of 150r/min or less) nor for emergency stop
(200 times at the motor speed of 3000r/min or less).
Over service beyond a limited time may deteriorate holding torque, and may
consequently become out of use as a brake.
4-2-2 Brake leads
Brake leads are included with motor leads in a motor cable. Leads are distinguished by the colors shown in the table below.
Color
Red
White
Black
Green/yellow
Blue
Yellow
shield
Lead
Motor-U
Motor-V
Motor-W
PE
Brake
Brake
FG
Note: the brake has no polarity.
!