OPERATION AND SAFETY

OPERATION

SAFETY

Press the Up or Down 
Direction Button.  

The limit switches will 
stop the lift platform 
level with the upper 
landing. At the bottom, 
the access ramp unfolds 
and rests on the ground.

Emergency Stop.  

Press the Emergency Stop 
button. This will prevent 
the lift from running 
in either direction. To 
operate the lift normally, 
pull the switch back out. 

NOTE:

 The sensor pan 

beneath the platform is 
designed to stop the lift 
when it hits an object 
underneath it. You can 
verify the operation of the 
sensor pan by starting the 
lift at the top landing. Press 
up on the sensor pan. While 
holding the pan in this 
location, press the down 
switch on the platform. The 
lift should not run. Check 
all sides and middle of the 
safety pan.

IMPORTANT: Read all instructions in this Owner’s Manual before 
operating the lift.

CAUTION: Center weight on lift’s platform. Lock brakes before 
operating lift when using with a wheelchair or scooter. Do not use 
lift if you suspect damage or wear.

This RPL meets ASME A18.1 safety standards. However, ensure
that you and those servicing this product follow all safety
procedures.

Do not disable any safety equipment or switches supplied with
this lift.

Lock wheelchair brakes before operating lift.

Stay away from all drive train components while the lift is
operating.

Do not exceed the maximum payload capacity of 600 lbs.

Do not ride on the lift until it is anchored in place.

It is recommended that a gate or door be installed at the upper
landing.

This product is designed only for lifting people and mobility
devices. Do not use for any other purpose.

Ensure that this lift is always disconnected from the electrical
source before servicing.

Loose clothing or jewelry should never be worn by a person
working on the lift

The lift requires a 115VAC 15 AMP grounded, dedicated
electrical outlet within 6 feet of the lift. Plug the lift directly

WARNING:

 Moving components can cut and crush. Do NOT 

operate the lift if you or anyone else is in close proximity to any 
drive components. Be aware that loose clothing or jewelry may 
catch on moving parts. 

WARNING: 

The area between the floor where the lift is mounted 

and the top landing must be covered by a smooth vertical fascia to 
eliminate pinch points between the platform and landing. 

Summary of Contents for Highlander RPL400

Page 1: ...o operate this Stair Lift If you do not clearly understand an instruction contact your dealer for clarification or call Harmar toll free at 866 378 6648 before operating the lift Residential Platform Lifts RPL400 RPL600 Owner s Manual andWarranty Information P N 610 00017 Rev C ...

Page 2: ...other with your mobility device It s easy to operate and virtually maintenance free to offer you many years of reliable use IMPORTANT Read and understand this Owner s Manual in its entirety before attempting to operate the equipment Follow all operating procedures to avoid possible injury and or property damage Contents Dealer Information 3 Owner Purchase Information 3 Special Benefits 4 Standard ...

Page 3: ...ess __________________________________________________________________ __________________________________________________________________ Telephone ____ __________________________________________________________ E mail ____________________________________________________________________ If service or warranty work is needed your Dealer will need the information below to receive factory information...

Page 4: ...ES Safety Sensors stop lift for obstacles Ramp folds up down automatically for smooth access and added stability Controls are simple safe and easy to use Data Serial Tag Top Cover Key Switch Control optional Wireless control optional Battery Power optional ...

Page 5: ...gency stop key switch optional Manual Lowering Provided Safety Features Safety pan final limit Acme safety nut with monitor and non skid surface Warranty 1 Year parts CODE AND SITE REQUIREMENTS Code Requirements This platform lift is designed to meet ASME A18 1 section 5 and CSA B44 ASME A17 5 with the addition of certain options Code requirements for vertical platform lifts vary depending on loca...

Page 6: ... A18 1 safety standards However ensure that you and those servicing this product follow all safety procedures Do not disable any safety equipment or switches supplied with this lift Lock wheelchair brakes before operating lift Stay away from all drive train components while the lift is operating Do not exceed the maximum payload capacity of 600 lbs Do not ride on the lift until it is anchored in p...

Page 7: ...nk to raise or lower the platform WARNING Never operate the lift while the Manual Override Crank is inserted into the lift For your safety if you have any questions please contact your Harmar dealer installer or Harmar s Technical Service Department at 1 866 378 6648 or e mail tech harmar com Clean the lift panels with a mild cleanser Dry thoroughly Do NOT use abrasive cleansers or materials Apply...

Page 8: ...ovide the serial number of the product along with a description and evidence of the defect s supporting a warranty claim Dealers may charge for labor service travel or other associated costs to make repairs and such charges are not covered by this Limited Warranty It is permissible to have any repairs or replacement work done as a result of any defects in material and workman ship by someone other...

Page 9: ...NOTES ...

Page 10: ...NOTES ...

Page 11: ...NOTES ...

Page 12: ...P N 610 00017 Rev B Highlander Residential Platform Lift Owner s Manual ...

Reviews: