background image

Code Requirements 

Your lift and enclosure have been designed to meet ASME A18.1 section 2 and 5 and CSA 

B44/ASME A17.5, with the addition of certain options. Code requirements for Vertical Platform lifts vary 

depending on location. 
It is the installers’ responsibility to contact their local code enforcement office and determine all of the 

regulations they are subject to. You must do this before installing the Vertical Platform Lift. If you have 

questions about this, feel free to call Harmar to be directed to the right officials. 

Site Requirements 

115vac 20amp grounded circuit, if outdoor, GFI protected..

Minimum 5” thick , level, 3,500 psi reinforced concrete slab sized to your specific install drawing.

If you choose to install the lift in a pit so the platform is at floor-level, Harmar recommends that the pit

be sized to install the enclosure in it also.

Required tools 

Step ladder 

Extension ladder or scaffold (helpful for

tall units)

Hammer Drill

3/8" Masonry Drill Bit, min 8” long

Appliance Dolly 

Hammer

Level

Measuring Tape 

Socket Wrench Set

Socket wrench or drill extensions up to

two-feet long (if installing walls from

platform)

Phillips screwdriver or bits, size #2 & #3

Wire stripper and cutter

Conduit cutters, punches and tools

needed with electrical conduit

Required materials 

Up to 14 concrete anchors, wedge-type. Harmar recommends securing the lift with our Anchor Kit p/n

If you use your own, we recommend 3/8-16 anchor bolts with embedment of 4 inches. These shall

have a min pull out strength of 3000 lbs-force. If used in an extreme environment (wet, salty), use

galvanized or stainless steel

Various shims, slotted preferred, but washers can work.  Min reqd. about 1/16

th

 thick, Qty, up to about

25 max.  These are to align enclosure and lift with the building. Often these aren’t needed.

Lag screws or similar and washers to attach upper portion of the enclosure to the building. You may

need lumber for this step too.

Up to ten wire nuts, med size.

Caulking, outdoor 25 year-silicone preferred

Electrical conduit and fittings.  For outdoor installation, use liquid-tite and appropriate fittings

Summary of Contents for HIGHLANDER EPL400

Page 1: ...operation For further assistance please contact your authorized Harmar dealer or Harmar s Technical Service department Tel 866 378 6648 Fax 816 537 0641 Enclosure with Commercial Platform Lift HIGHLA...

Page 2: ...9 Installing the fixed ramp 11 Anchoring the Lift 12 Setting the Limit Switches 13 Verifying Operation of the Lift 14 Manual Override 15 Call Sends optional 1 Top Landing Gate optional 1 EMI and Flush...

Page 3: ...d 10 ft min Motor 1 2hp 90vdc or 1 2hp 24vdc Safety Read all instructions in this manual before installing or operating the lift Do not exceed the maximum payload capacity of 750 lbs Do not ride on th...

Page 4: ...rill 3 8 Masonry Drill Bit min 8 long Appliance Dolly Hammer Level Measuring Tape Socket Wrench Set Socket wrench or drill extensions up to two feet long if installing walls from platform Phillips scr...

Page 5: ...3 sided enclosure the area between the lower floor and the top landing must be smooth and vertical so that the distance from the wall to the platform will stay between 3 8 and to meet code This is to...

Page 6: ...e a safety pan Part of the enclosure will serve as the top cap and a pit switch does the duty of the safety pan Step 3 Position the lift to the building according to the dimensions below Note that bot...

Page 7: ...e panels on the wall side first because you won t have access to these bolts and holes when it s together If you have a really tall tower you ll be able to bend it out to put in the higher bolts but g...

Page 8: ...t legs with the carriage flanges that protrude from the front cover Step 3 Align the four mounting holes with those on the carriage Insert x 3 hex head bolts into each of the 4 holes Install the low p...

Page 9: ...you re able to put on the Lift Top Cap For lifts taller than eight foot lift you may skip ahead to the anchor step page 10 Step 3 Your door will come assembled to the frame and may already be on the...

Page 10: ...adjust the upper and lower limit switches to make the lift stop exactly where needed Sometimes it comes from the factory right so this isn t required Step 5 You have received one piece of Plexiglas th...

Page 11: ...g the provided bracket and bolt to inner guard panel Step 2 Install the platform control box on the rear guard panel using screws and nuts through the panel Step 3 Plug in the harness for the platform...

Page 12: ...crete dust may have settled into the holes you just drilled Use a shop vacuum to clean out these holes This will ensure the floor anchors set correctly Step 3 Secure the lift in place by tightening th...

Page 13: ...h the front cover Step 3 Remove the front cover by tilting it forward and lifting upwards The bottom of the front cover sits on a pin on either side of the lift frame Set the cover aside in a safe loc...

Page 14: ...if equipped unfolds and rests on the ground Step 2 Verify the operation of the Emergency stop switch When this switch is pushed in the lift should not run in either direction When this switch is turne...

Page 15: ...op of the brake assembly It may be necessary to slightly rotate the handcrank until it fully seats down on the hex portion of the brake Rotate the crank to raise or lower the platform Warning Never op...

Page 16: ...clarity There are a number of attachment holes provided in the threshold portion of the gate for mounting using wood lag screws or concrete anchors as appropriate Remove the latch post cover and conne...

Page 17: ...or jamb and mark mounting holes 2 Fasten Interlock to door jamb with 8 wood screws 3 Route 4 conductor Interlock cable thru hole in top of interlock and make wire connections 4 Attach door keeper and...

Page 18: ...d sounds an alarm when pressed You will need to obtain a 6 volt lantern battery like the example below The battery can sit under the top cap to the right of the motor pulley There is a wire harness fo...

Page 19: ...Commercial Platform Lift Owners Section Read the manual thoroughly before operating the lift 19...

Page 20: ...ned only for lifting people and wheel chairs Do not use it for any other purpose Make sure any obstructions are cleared from underneath the platform area before use Make sure both the passenger and wh...

Page 21: ...atform To move platform up depress and hold the upper half of the rocker switch To cease movement release switch Down Controls downward movement of lift platform To move platform down depress and hold...

Page 22: ...tivated by giving it a quick turn clockwise Step 3 Press and hold the UP rocker The lift will move in the up direction and stop when it reaches the upper landing Warning Always verify the lift s platf...

Page 23: ...giving it a quick turn clockwise Step 3 Press and hold the DOWN rocker The lift will move in the down direction and stop when it reaches the lower landing Warning Always verify the lift s access ramp...

Page 24: ...s 5 6VDC UP 3 4 Brake RED BLK Belt Monitor C NO C NC NO NO 14 15 16 L1 L2 G 4 Terminal Strip Connection Switch N C Switch N O held closed Push Button Contact N O Contact N C Circuit Breaker Legend Opt...

Page 25: ...latform Gate Optional Top Landing Gate Optional Lighted Alarm Call Send NC NO NC Lower Bypass Upper Bypass NO Optional Top or Bottom Electric Door Strike Optional Top or Bottom Electric Door Strike 1...

Page 26: ...Strip Connection Switch N C Switch N O held closed Push Button Contact N O Contact N C Circuit Breaker Legend Optional Equipment Call Station NO NO NO NO C C C C UP 2 1 DN 1 2 15V Sig 15V L2 L1 90VDC...

Page 27: ...8 9 5 1 2 1 2 3 4 6 5 1 2 3 4 6 5 1 2 3 4 6 7 8 9 5 1 2 3 1 2 3 1 2 3 4 1 2 1 2 3 4 6 5 1 2 3 15V Sig 15V L2 L1 90VDC Output 12A Regen Drive Tach Com EN NO Belt Monitor 1 1 Electric Strike Power 1 1 2...

Page 28: ...OPTIONAL Terminal Strip Connection Safety Pan Switches 2 3 8 4 10 11 1 Switch N C Switch N O held closed Push Button Contact N O Contact N C 7 7 7 Circuit Breaker Legend 30 Amp 3 Amp Top Gate Closed 6...

Page 29: ...d 49300 Gate Call Send HRNS 44012 Limit Switch HRNS 44007 NO C NO SOL Gate Closed C NO SOL Gate Closed Optional Phone Jack Optional Platform Gate Optional Top Landing Gate Optional Lighted Alarm Call...

Page 30: ...VDC Belt Monitor NO Optional Equipment NC NO NO 14 15 16 U2 A1 A2 D2 A1 A2 SAF D2 D2 12 VDC BATTERY CHARGER 24 VDC 12 VDC 24VDC BRAKE NO NO NO NO Mid 4 3 2 1 8 7 6 5 Mid Lmt Mid Interlock Solenoid Cal...

Page 31: ...vide the serial number of the product along with a description and evidence of the defect s supporting a warranty claim Dealers may charge for labor service travel or other associated costs to make re...

Page 32: ...P N 630 00048 Rev C Highlander Enclosed Platform Lift Installation and Owners Manual...

Reviews: