CAUTION:

 

HOT wHIle  IN  OperATION. DO  NOT  TOUCH. 

Keep CHIlDreN AND ClOTHINg AwAy. CONTACT mAy CAUse sKIN 

bUrNs. see NAmeplATe AND INsTrUCTIONs. Keep fUrNIsHINgs 

AND OTHer COmbUsTIble mATerIAls A CONsIDerAble DIsTANCe 

AwAy frOm THIs ApplIANCe.

ATTeNTION:

 

CHAUD LORS DU FONCTIONNEMENT. NE 

TOUCHEZ PAS L’APPAREIL.GARDEZ LES ENFANTS ET LES VÊTEMENTS ÉLOIGNÉS. 

TOUT CONTACT PEUT ENTRAÎNER DES BRÛLURES DE LA PEAU. RÉFÉREZ-VOUS À LA 

PLAQUE SIGNALÉTIQUE ET AU MODE D’EMPLOI. GARDEZ LE MOBILIER ET LES AUTRES 

MATÉRIAUX COMBUSTIBLES BIEN À L’ÉCART DE L’APPAREIL.

Floor protection must be a non-combustible material. Must also be placed under any horizontal sections of flue connector, extending 

2” (51mm) beyond the measurement of the pipe.  

Pour protéger le plancher, il faut sous le poêle un matériau. Qui doit aussi être placé sous les parties horizontales du tuyau de raccord 

à la cheminée et s’étendre à 51 mm (2 po) au-delà de la mesure du tuyau.

BARCODE LABEL

008

Serial No.

N

o

 de série:

Rev E

P.N. 3-90-06900

e

f

CLEARANCE TO COMBUSTIBLE SURFACES

A - Unit to Sidewall 

20”

B - Unit to Backwall 

18”

C - Chimney Connector to Sidewall 

31”

D - Chimney Connector to Backwall 

24”

E - Unit to Adjacent Wall 

18”

F - Chimney Connector to Adjacent Wall  27”

A

C

b

D

ESPACES LIBRES AUX COMBUSTIBLES

A - Entre le mur lateral et l’appareil 

500mm

B - Entre le mur arriereet l’appareil 

450mm

C - Entre le tuyau et le mur lateral 

775mm

D - Entre le tuyau et le mur arriere 

600mm

E - Entre le mur adjacent et l’appareil 

450mm

F - Entre le tuyau et le mur adjacent 

675mm

FLOOR PROTECTION / Protection Du Planche

 

USA

 

Canada

Sides*/Côtés  (A) 

8” 

200mm

Back**/Arrière  (B) 

8” 

200mm

Front*/Avant  (C) 

18” 

457mm

A

b

b

C

352 Mountain House Road

Halifax, PA 17032

ECO: 
PARt # / REv:  3-90-06900_RevE
ORiginAtOR:  Spidlet
DAtE:  04/15
LAbEL SizE:  5” H. x 15” W
LOCAtiOn: 

Rear Heat Shield - top

CLASS: 
ADHESivE: 486
MAtERiAL: MEtAL
ink: bLACk
OvERCOAt:

LAbEL tiCkEt

.260 W x .140 H Oblong holes on each end.

Corners .062

MODEL / MODÈLE: “TL300” Woodburning Stove

Room Heater Solid Fuel Burning Type

SUITABLE FOR MOBILE-HOME INSTALLATION 

(USA ONLY)

Made in U.S.A. of US and imported parts. / Fabriqué aux États-Unis-

d’Amérique par des pièces d’origine américaine et pièces importées.

Report#/Rapport

 #135-S-18-6, 135-S-18b-6.2

Tested to/Teste a:

 UL 1482-2010, UL 737-2007, ULC-S627-00, EPA Method 28 & 5G

Approved For Use in Mobile/Manufactured Homes (UM) 84-HUD - 

USA ONLY

“PREVENT HOUSE FIRES” 

Install and use only in accordance with manufacturer’s installation and 

operation instructions and local codes. In absence of local codes, installation must meet minimum 

requirements of NFPA 211 in USA. Refer to manufacturer’s instructions and local codes for precautions 

required for passing chimney through a combustible wall or ceiling.

This wood heater needs periodic inspection and repair for proper operation. Consult the owner’s 

manual for further information. It is against federal regulations to operate this wood heater in a manner 

inconsistent with the operating instructions in the owner’s manual.

WARNING: FOR MANUFACTURED HOMES:

 (US Only) Do not install appliance in a sleeping room. An 

outside air inlet must be provided. The structural integrity of the manufactured home’s floor, walls, and 

ceiling must be maintained.

Flue connector pipe must be 6” diameter, minimum 24 MSG blue steel. Chimney must be factory built  

103HT or masonry construction. Contact Local Building or Fire Officials about restrictions and 

installation inspection in your area.

 

DO NOT CONNECT THIS APPLIANCE TO A CHIMNEY SERVING ANOTHER APPLIANCE.

FOr USE WiTh SOLiD WOOD FUEL OnLy, DO nOT bUrn cOAL.

EPA Certified Emissions: 1.1 g/hr

Fuel Type: Cord Wood

DO nOT Overfire - if heater or chimney connector glows, you are overfiring.

Optional Blower Harman #1-00-08118: Electrical Rating 115 VAC, 60Hz, 1AMP Maximum 

route power cord away from unit.

OPERATE ONLY WITH DOORS CLOSED

 

Replace glass only with 5mm ceramic, available from your dealer.

Combustible flooring must be protected with an approved 0.45R hearth board.

Appliance must be installed with the legs attached. Do not obstruct airflow under the appliance.

DAnGEr: risk of Fire or Explosion - Do not burn garbage,  gasoline, drain oil or other flammable 

liquids.

WArninG: risk of Fire, Do not operate with fuel loading or ash removal doors open.

Do not store fuel or combustibles within marked clearances. inspect and clean chimney and 

connector regularly - Under certain conditions of use, creosote buildup may occur rapidly.

The bypass Damper must be opened prior to opening any load or ash door.

Do not install a grate or otherwise elevate the fire.

Maisons approuvé pour utilisation à Mobile / manufacturés (UM) 84-HUD - 

USA SEULEMENT

"Empêcher MAiSOn incendies"

 Installer et utiliser uniquement en conformité avec installation 

et d'utilisation les instructions du fabricant et les codes locaux. En l'absence de codes locaux, 

l'installation doit satisfaire aux exigences minimales de la norme NFPA 211 aux Etats-Unis. 

Reportez-vous aux instructions du fabricant et les codes locaux pour les précautions nécessaires 

pour faire passer la cheminée à travers un mur ou un plafond combustible.

Ce poêle à bois doit inspection périodique et la réparation pour un fonctionnement correct. 

Consultez le manuel du propriétaire pour plus d'informations. Ce est contre les règlements 

fédéraux pour faire fonctionner ce poêle à bois d'une manière incompatible avec les instructions 

d'utilisation dans le manuel du propriétaire.

AVERTISSEMENT: POUR maisons préfabriquées:

 (États-Unis uniquement) Ne pas installer 

l'appareil dans une chambre à coucher. Une entrée d'air extérieur doit être fournie. L'intégrité 

structurale du sol, les murs et le plafond de la maison préfabriquée doit être maintenue.

Tuyau de raccordement de fumée doit être de 6 "de diamètre, en acier au minimum 24 MSG 

bleu. Cheminée doit être construite l'usine 103HT ou la construction de maçonnerie. Contactez 

Immeuble Local ou fonctionnaires incendie au sujet des restrictions et l'inspection d'installation 

dans votre région.

NE PAS brancher l'appareil à une cheminée desservant un autre APPAREIL.

Pour une utilisation avec Solid combustible bois Seulement, ne pas brûler de charbon.

Émissions certifiés EPA: 1,11 g / h

Type de carburant: Cordon bois

nE SUrchAUFFEZ - Si le connecteur chauffe ou de la cheminée rougeoie, vous surchauffez.

Facultatif Blower Harman # 1-00-08118: Note électrique 115 VAC, 60Hz, 1AMP maximum

Route cordon électrique de l'appareil.

FOncTiOnnEr UniQUEMEnT AvEc LES POrTES FErMÉES

Remplacer le verre seulement avec de la céramique 5mm, disponible chez votre revendeur.

Plancher combustible doit être protégé par un conseil 0.45R foyer approuvé.

L'appareil doit être installé avec les jambes attachées. Ne pas obstruer le flux d'air sous l'appareil.

DAnGEr:  risque  d'incendie  ou  d'explosion  -  ne  pas  brûler  de  déchets,  de  l'essence, 

vidanger l'huile ou d'autres liquides inflammables.

AvErTiSSEMEnT: risque d'incendie, ne pas fonctionner avec chargement de combustible 

ou d'enlèvement de cendres portes ouvertes.

ne pas stocker carburants ou de combustibles dans les dégagements marqués. inspectez 

et cheminée propre et le connecteur régulièrement - Dans certaines conditions d'utilisation, 

l'accumulation de créosote peut se produire rapidement.

Le bypass amortisseur doit être ouvert avant d'ouvrir ne importe quelle porte de charge 

ou de la cendre.

ne pas installer une grille ou autrement surélever le feu.

Date of Manufacture / Date de fabrication:

2015   2016   2017   JAN   feb   mAr   Apr   mAy   JUN   JUl   AUg   sep   OCT   NOV   DeC

Manufactured by / Fabriqué par: hearth and home Technologies 352 Mountain house road, halifax PA 17032

US ENVIRONMENTAL PROTECTION AGENCY

certified to comply with 2015 particulate emission standards. not approved for sale after May 15, 2020.

certifié conforme aux normes 2015 d’émission de particules. non approuvé pour la vente après le 15 mai 2020.

Hearth & Home Technologies welcomes you to our tradition of excellence! By choosing a Harman appliance, you have become 

part of our commitment to meeting the heating needs of consumers with the most distinctive, powerful and responsible home 

heating products available. 
With it's compact, steel-body construction, the TL300 takes advantage of Harman’s 30+ years of stove design, technology and 

manufacturing. The Firedome Plus secondary combustion system provides for super-clean burning and minimal maintenance. 

The top-loading feature makes for more convenient loading, with enough fuel for an all day burn.
We wish you and your family many years of enjoyment in the warmth and comfort of your hearth appliance.
Thank you for choosing Harman.
This Label is located on the rear of the appliance. It contains important safety test information as well as the clearances to 

combustible materials. The label also contains the appliance serial number. For your records, copy your serial number and 

purchase date here.

Serial #: ________________________    

Date of Purchase: ________________________

SAMPLE LABEL

Summary of Contents for TL300

Page 1: ...ULLY SUPERVISE children in same room as fireplace Alert children and adults to hazards of high temperatures High temperatures may ignite clothing or other flammable materials Keep clothing furniture d...

Page 2: ...inspect and clean chimney and connector regularly Under certain conditions of use creosote buildup may occur rapidly The bypass Damper must be opened prior to opening any load or ash door Do not insta...

Page 3: ...nt Locator 7 D Pre Use Checklist 8 Section 4 Dimensions Clearances A Appliance Dimensions 9 B Clearances to Combustibles 10 C Floor Protection 12 Section 5 Chimneys Venting A Draft 13 B Chimney Connec...

Page 4: ...omply with 2015 particulate emission standards Not approved for sale after May 15 2020 MODEL TL300 Woodburning Stove LABORATORY OMNI Test Laboratories Inc REPORT NO 135 S 18b 6 2 TYPE Solid Fuel Room...

Page 5: ...lation by opening windows or doors 2 Make sure the stove doors and lid are closed and latched 3 Check stove for smoking or puffing condition Open by pass and increase air flow to firebox if needed 4 C...

Page 6: ...and floor protection before actually beginning the installation When installing on a combustible floor proper floor protection material must be used See page 12 for details Maintain specified vent cle...

Page 7: ...These Instructions Harman TL300 Owner s Manual_R25 2007 ___ 08 15 C Component Locations Andirons Grate Air Control Front Load Door Top Load Door Handle Ash Door Ash Door Latch Front Load Door Latch T...

Page 8: ...appliance in a location near the final installation and follow the procedures below 2 Open the appliance and remove all articles packed inside Inspect all items for shipping damage Notify dealer of a...

Page 9: ...00 Owner s Manual_R25 2007 ___ 08 15 A Appliance Dimensions 4 Dimensions Clearances 37 7 16 951 mm 29 3 8 746 mm 13 1 16 332 mm 23 3 8 594 mm 27 1 16 687 mm 8 15 16 227 mm 37 7 16 951 mm 29 3 8 746 mm...

Page 10: ...pe to Side Wall 31 787mm 28 711mm D Vent Pipe to Back Wall 24 610mm 18 5 470mm Corner Installation E Corner to Adjacent Wall 18 457mm 18 457mm F Connector to Wall 27 686mm 27 686mm For clearance reduc...

Page 11: ...e Wall 31 787mm D Vent Pipe to Back Wall 24 610mm E Vent Pipe to Ceiling 15 381mm Corner Installation F Corner to Adjacent Wall 18 457mm G Connector to Wall 27 686mm For clearance reduction methods re...

Page 12: ...ing in The United States In Canada the side dimension is measured from the widest part of the appliance Parallel versus Corner Installations A parallel installation is one in which the back and sides...

Page 13: ...size of the flue collar opening which is 6 152mm Do not use makeshift compromises No part of the chimney connector may pass through an attic or roof space closet or other concealed space or through a...

Page 14: ...ghest point at which they exit from the roof Then the chimney must extend 2 ft 0 6m above the highest point within a 10ft 3m radius Thus the 3 foot 2 foot 10 foot rule 3ft Above roof exit point 2ft Hi...

Page 15: ...in this section Since many fireplaces have exposed wooden mantels and trim pay special attention to the clearances necessary to these materials If your fireplace chimney is behind a combustible wall y...

Page 16: ...c or Roof Space Closet or Similar Concealed Space a Floor or Ceiling Chimney Connector Minimum air space with chimney listing Chimney support Attic radiation shield Chimney sections Chimney cap Storm...

Page 17: ...300 Owner s Manual_R25 2007 ___ 08 15 Chimney Connector Cathedral style chimney support Finishing collar Roof radiation shield Chimney cap Sealed storm collar Roof flashing Factory Built metal chimney...

Page 18: ...Similar Concealed Space a Floor or Ceiling Minimum clearance to unprotected ceiling 15 Chimney connector sealed at thimble Flue liner with required air space Minimum of three sheet metal screws per j...

Page 19: ...to uprotected ceiling 15 Flue liner with required air space Listed or approved thimble assembly 1 Clearance for exterior chimney or 2 clearance for interior chimney and 2 clearance for NFPA 211 type a...

Page 20: ...te an effective vapor barrier at the location where the chimney or other component penetrates to the exterior 8 Installation shall be in accordance with the Manufactured Home and Safety Standard HUD C...

Page 21: ...end of the metal intake flex pipe into the stub on the rear of the stove and secure it with aluminum tape This air intake will supply outside air for the secondary combustion 7 Secure the trim ring i...

Page 22: ...g from the hinges Lay the door down flat on it s face Drill the dimpled holes in each corner of the door and re install the door onto the stove From the outside install the frame with the studs going...

Page 23: ...the door closed with the handle in the open position then turn counter clockwise to engage the latch Ash Door To open the ash door lift up the handle and pull out Close the door by pushing in and pus...

Page 24: ...here the charcoal burns the remaining heat content in the wood fuel Ash remains after the burning is complete Within the primary firebox two or more of these stages of combustion are occurring at once...

Page 25: ...this start up fire to burn for a few minutes keeping the bypass damper open Add about five more pieces of wood in the 2 to 3 inch 50 80mm size range making sure that the fuel bed is all the way across...

Page 26: ...the fire chamber periodically by raking a poker across the bottom grates Excessive ash buildup can prevent proper venting of exhaust gases Do not allow the ash pan to over fill Ash buildup between th...

Page 27: ...e cleaned regularly as soot ash and creosote may accumulate ALWAYS WEAR FIRE RESISTANT GLOVES TO OPERATE THE STOVE THE AIR CONTROL IS HOT WHILE IN OPERATION CAUTION When properly maintained your stove...

Page 28: ...burial in soil or otherwise locally dispersed they should be retained in the closed container until all cinders have completely cooled Other waste shall not be placed in this container Glass Retainer...

Page 29: ...nately with some minor disassembly you can use a vacuum and or brush to clean the blower wheel Reinstall the blower and tighten the four bolts securely Chimney Connector Frequency As necessary Yearly...

Page 30: ...ist on following page Wood Stove Retired Units 1 90 06900 2 Charcoal Ending Manufacturing Date June 2011 1 90 06900 3 Golden re Ending Manufacturing Date June 2011 1 90 06900 4 Metallic Blue Ending Ma...

Page 31: ...A Y Dowel Pin 250 x 375 Pkg of 15 3 30 2019 15 Top Load Door Gasket Plate 1 10 40020 Y Gasket Top Load Door 1 00 10050 Y Hinge Spacer Qty 2 req 2 00 40021L Lid Hinge Set Bottom 1 00 40022 Y Nut Zinc P...

Page 32: ...t 2 00 06963B 17 2 Air Slide Adjuster 1 10 06964W 17 3 Air Slide Weldment 1 10 06950W 18 1 Push On Cap Lift Arm Pre 008323415 3 31 500015 18 2 Wooden Knob 3 40 06956 Y 18 3 Damper Linkage Arm Weldment...

Page 33: ...cludes Damper 1 10 249106 Y Adjuster w Hardware Pre 008323034 1 00 249142 Y Post 008323034 1 00 250153 Damper w Adjuster 1 10 249107 Damper Shaft Retainers and Hardware 1 Set 1 00 249145 Y Gasket 3 8...

Page 34: ...Qty 2 req 3 00 773813 Blower Option 1 00 08118 105 CFM Blower w VSC 3 21 50757 Y Blower Mounting Plate 2 00 05218P Hex Cap Screw for Blower Mounting Plate Pkg of 50 3 30 1108 50 Y Gasket 1 4 Round w A...

Page 35: ...In the case of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distrib...

Page 36: ...ED ABOVE WARRANTY EXCLUSIONS This warranty does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surf...

Page 37: ...Save These Instructions Harman TL300 Owner s Manual_R25 2007 ___ 08 15 3 90 06901 Service Maintenance Log Date Of Service Performed By Description Of Service...

Page 38: ...________________________________________________________________________________ ________________________________________________________________________________ _____________________________________...

Reviews: