background image

24

Dry Seasoned Wood Only!

Save These Instructions

Harman®  •  TL300 Owner's Manual_R25  •  2007 -___  •  08/15

D. The Combustion Process

Combustion in the firebox is precisely controlled and is best 

explained in two parts.

During a wood fire, combustion air enters at the bottom front 

of the stove where it travels upward through channels at either 

side of the front door. From the manifold located above the 

front door, it is directed into the firebox as a sheet of air flowing 

between the glass and the wood. This concept helps to keep 

the glass clean, while providing the oxygen needed to sustain 

burning. This is what is known as "Primary Combustion". 
Additional air enters at the bottom rear of the stove body. 

Some of this air enters through holes in the rear bricks where 

it is used to revitalize the fire at the rear of the firebox. The 

remainder is delivered into the "Firedome Plus" combustion 

package where the "Secondary Combustion", or re-burning 

of the smoke, occurs.
During combustion, the burning of wood proceeds through 

several stages. The initial or evaporation stage is where 

the moisture in the wood is driven off in the form of steam. 

A second stage is where the volatile gases contained in the 

wood are released and burned. This represents most of the 

wood's heating capacity. The final stage is the charcoal stage 

where the charcoal burns the remaining heat content in the 

wood fuel. Ash remains after the burning is complete. Within 

the primary firebox two or more of these stages of combustion 

are occurring at once.
Always be sure to provide adequate ventilation to the room 

where the appliance is located, to prevent air starvation. 

In tight construction, consider installing outside air to the 

appliance.

Grates 

The unique grate system consists of one

 

flat bottom grate, 

and two front andirons. The bottom grate has slots which 

allow the ash to fall into the ash pan by passing a poker back 

and forth across the grate. The andirons keep the fuel from 

coming into direct contact with the glass, and keep hot coals 

and embers from spilling out while reloading. Never build a 

fire directly against the glass.

The grates and andirons must remain in place at all 

times. Do not tamper with or change the configuration 

of this grate system.

C. Burning as a Fireplace

This appliance has been tested and approved for burning as 

an open fireplace. To do so, a spark screen (Harman part# 

3-40-06960; Cozy Screen) must be installed over the front 

door opening. The by-pass damper must be kept in the open 

position. 

The Cozy Screen can be used from the start of a fire or can 

be used with an existing one. When starting a fire with the 

Cozy Screen, smoke spillage may occur until it develops a 

draft strong enough to pull all smoke back into the flue.

DO NOT LEAVE THE APPLIANCE UNATTENDED WITH 

THE DOOR OPEN!
Load only small amounts of wood at a time.

Summary of Contents for TL300

Page 1: ...ULLY SUPERVISE children in same room as fireplace Alert children and adults to hazards of high temperatures High temperatures may ignite clothing or other flammable materials Keep clothing furniture d...

Page 2: ...inspect and clean chimney and connector regularly Under certain conditions of use creosote buildup may occur rapidly The bypass Damper must be opened prior to opening any load or ash door Do not insta...

Page 3: ...nt Locator 7 D Pre Use Checklist 8 Section 4 Dimensions Clearances A Appliance Dimensions 9 B Clearances to Combustibles 10 C Floor Protection 12 Section 5 Chimneys Venting A Draft 13 B Chimney Connec...

Page 4: ...omply with 2015 particulate emission standards Not approved for sale after May 15 2020 MODEL TL300 Woodburning Stove LABORATORY OMNI Test Laboratories Inc REPORT NO 135 S 18b 6 2 TYPE Solid Fuel Room...

Page 5: ...lation by opening windows or doors 2 Make sure the stove doors and lid are closed and latched 3 Check stove for smoking or puffing condition Open by pass and increase air flow to firebox if needed 4 C...

Page 6: ...and floor protection before actually beginning the installation When installing on a combustible floor proper floor protection material must be used See page 12 for details Maintain specified vent cle...

Page 7: ...These Instructions Harman TL300 Owner s Manual_R25 2007 ___ 08 15 C Component Locations Andirons Grate Air Control Front Load Door Top Load Door Handle Ash Door Ash Door Latch Front Load Door Latch T...

Page 8: ...appliance in a location near the final installation and follow the procedures below 2 Open the appliance and remove all articles packed inside Inspect all items for shipping damage Notify dealer of a...

Page 9: ...00 Owner s Manual_R25 2007 ___ 08 15 A Appliance Dimensions 4 Dimensions Clearances 37 7 16 951 mm 29 3 8 746 mm 13 1 16 332 mm 23 3 8 594 mm 27 1 16 687 mm 8 15 16 227 mm 37 7 16 951 mm 29 3 8 746 mm...

Page 10: ...pe to Side Wall 31 787mm 28 711mm D Vent Pipe to Back Wall 24 610mm 18 5 470mm Corner Installation E Corner to Adjacent Wall 18 457mm 18 457mm F Connector to Wall 27 686mm 27 686mm For clearance reduc...

Page 11: ...e Wall 31 787mm D Vent Pipe to Back Wall 24 610mm E Vent Pipe to Ceiling 15 381mm Corner Installation F Corner to Adjacent Wall 18 457mm G Connector to Wall 27 686mm For clearance reduction methods re...

Page 12: ...ing in The United States In Canada the side dimension is measured from the widest part of the appliance Parallel versus Corner Installations A parallel installation is one in which the back and sides...

Page 13: ...size of the flue collar opening which is 6 152mm Do not use makeshift compromises No part of the chimney connector may pass through an attic or roof space closet or other concealed space or through a...

Page 14: ...ghest point at which they exit from the roof Then the chimney must extend 2 ft 0 6m above the highest point within a 10ft 3m radius Thus the 3 foot 2 foot 10 foot rule 3ft Above roof exit point 2ft Hi...

Page 15: ...in this section Since many fireplaces have exposed wooden mantels and trim pay special attention to the clearances necessary to these materials If your fireplace chimney is behind a combustible wall y...

Page 16: ...c or Roof Space Closet or Similar Concealed Space a Floor or Ceiling Chimney Connector Minimum air space with chimney listing Chimney support Attic radiation shield Chimney sections Chimney cap Storm...

Page 17: ...300 Owner s Manual_R25 2007 ___ 08 15 Chimney Connector Cathedral style chimney support Finishing collar Roof radiation shield Chimney cap Sealed storm collar Roof flashing Factory Built metal chimney...

Page 18: ...Similar Concealed Space a Floor or Ceiling Minimum clearance to unprotected ceiling 15 Chimney connector sealed at thimble Flue liner with required air space Minimum of three sheet metal screws per j...

Page 19: ...to uprotected ceiling 15 Flue liner with required air space Listed or approved thimble assembly 1 Clearance for exterior chimney or 2 clearance for interior chimney and 2 clearance for NFPA 211 type a...

Page 20: ...te an effective vapor barrier at the location where the chimney or other component penetrates to the exterior 8 Installation shall be in accordance with the Manufactured Home and Safety Standard HUD C...

Page 21: ...end of the metal intake flex pipe into the stub on the rear of the stove and secure it with aluminum tape This air intake will supply outside air for the secondary combustion 7 Secure the trim ring i...

Page 22: ...g from the hinges Lay the door down flat on it s face Drill the dimpled holes in each corner of the door and re install the door onto the stove From the outside install the frame with the studs going...

Page 23: ...the door closed with the handle in the open position then turn counter clockwise to engage the latch Ash Door To open the ash door lift up the handle and pull out Close the door by pushing in and pus...

Page 24: ...here the charcoal burns the remaining heat content in the wood fuel Ash remains after the burning is complete Within the primary firebox two or more of these stages of combustion are occurring at once...

Page 25: ...this start up fire to burn for a few minutes keeping the bypass damper open Add about five more pieces of wood in the 2 to 3 inch 50 80mm size range making sure that the fuel bed is all the way across...

Page 26: ...the fire chamber periodically by raking a poker across the bottom grates Excessive ash buildup can prevent proper venting of exhaust gases Do not allow the ash pan to over fill Ash buildup between th...

Page 27: ...e cleaned regularly as soot ash and creosote may accumulate ALWAYS WEAR FIRE RESISTANT GLOVES TO OPERATE THE STOVE THE AIR CONTROL IS HOT WHILE IN OPERATION CAUTION When properly maintained your stove...

Page 28: ...burial in soil or otherwise locally dispersed they should be retained in the closed container until all cinders have completely cooled Other waste shall not be placed in this container Glass Retainer...

Page 29: ...nately with some minor disassembly you can use a vacuum and or brush to clean the blower wheel Reinstall the blower and tighten the four bolts securely Chimney Connector Frequency As necessary Yearly...

Page 30: ...ist on following page Wood Stove Retired Units 1 90 06900 2 Charcoal Ending Manufacturing Date June 2011 1 90 06900 3 Golden re Ending Manufacturing Date June 2011 1 90 06900 4 Metallic Blue Ending Ma...

Page 31: ...A Y Dowel Pin 250 x 375 Pkg of 15 3 30 2019 15 Top Load Door Gasket Plate 1 10 40020 Y Gasket Top Load Door 1 00 10050 Y Hinge Spacer Qty 2 req 2 00 40021L Lid Hinge Set Bottom 1 00 40022 Y Nut Zinc P...

Page 32: ...t 2 00 06963B 17 2 Air Slide Adjuster 1 10 06964W 17 3 Air Slide Weldment 1 10 06950W 18 1 Push On Cap Lift Arm Pre 008323415 3 31 500015 18 2 Wooden Knob 3 40 06956 Y 18 3 Damper Linkage Arm Weldment...

Page 33: ...cludes Damper 1 10 249106 Y Adjuster w Hardware Pre 008323034 1 00 249142 Y Post 008323034 1 00 250153 Damper w Adjuster 1 10 249107 Damper Shaft Retainers and Hardware 1 Set 1 00 249145 Y Gasket 3 8...

Page 34: ...Qty 2 req 3 00 773813 Blower Option 1 00 08118 105 CFM Blower w VSC 3 21 50757 Y Blower Mounting Plate 2 00 05218P Hex Cap Screw for Blower Mounting Plate Pkg of 50 3 30 1108 50 Y Gasket 1 4 Round w A...

Page 35: ...In the case of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distrib...

Page 36: ...ED ABOVE WARRANTY EXCLUSIONS This warranty does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surf...

Page 37: ...Save These Instructions Harman TL300 Owner s Manual_R25 2007 ___ 08 15 3 90 06901 Service Maintenance Log Date Of Service Performed By Description Of Service...

Page 38: ...________________________________________________________________________________ ________________________________________________________________________________ _____________________________________...

Reviews: