background image

2

  Dry  Seasoned  Wood  Only!                               

TL2.6 Woodburning Stove

Save These Instructions

Harman®  •  TL2.6 Owner's Manual_R25  •  2011 -___  •  09/15

Report #/ Raport #

135-S-30-2, 135-S-30b-6.2

Tested to / Testé à:

 UL 1482-2011, UL 737-2011, ULC-S627-00, EPA Method 28 & 5G

Approved For Use in Mobile/Manufactured Homes (UM) 84-HUD - 

USA ONLY

“PREVENT HOUSE FIRES” 

Install and use only in accordance with manufacturer’s installation 

and operation instructions and local codes. In absence of local codes, installation must meet 

minimum requirements of NFPA 211 in USA. Refer to manufacturer’s instructions and local codes 

for precautions required for passing chimney through a combustible wall or ceiling.

This wood heater needs periodic inspection and repair for proper operation. Consult the owner’s 

manual for further information. It is against federal regulations to operate this wood heater in a 

manner inconsistent with the operating instructions in the owner’s manual.

WARNING: FOR MANUFACTURED HOMES:

 (US Only) Do not install appliance in a sleeping 

room. An outside air inlet must be provided. The structural integrity of the manufactured home’s 

floor, walls, and ceiling must be maintained.

Flue connector pipe must be 6” diameter, minimum 24 MSG blue steel. Chimney must be factory 

built 103HT or masonry construction. Contact Local Building or Fire Officials about restrictions and 

installation inspection in your area.

DO NOT CONNECT THIS APPLIANCE TO A CHIMNEY SERVING ANOTHER APPLIANCE.

FOR USE WITH SOLID WOOD FUEL ONLY, DO NOT bURN COAL.

EPA Certified Emissions: 3.7 g/hr

Fuel Type: 

Cord Wood

DO NOT Overfire - If Heater or chimney connector glows, you are overfiring.

Optional Blower Harman #1-00-856082: Electrical Rating 115 VAC, 60Hz, 1AMP Maximum 

Route power cord away from unit.

OPERATE ONLY WITH DOORS CLOSED

 

Replace glass only with 5mm ceramic, available from your dealer.

Combustible flooring must be protected with an approved 0.45R hearth board.

Appliance must be installed with the legs attached. Do not obstruct airflow under the appliance.

DANGER: Risk of Fire or Explosion - Do not burn garbage,  gasoline, drain oil or other 

flammable liquids.

WARNING: Risk of Fire, Do not operate with fuel loading or ash removal doors open.

Do not store fuel or combustibles within marked clearances. Inspect and clean chimney 

and connector regularly - Under certain conditions of use, creosote buildup may occur 

rapidly.

The Bypass Damper must be opened prior to opening any load or ash door.

Do not install a grate or otherwise elevate the fire.

Maisons approuvé pour utilisation à Mobile / manufacturés (UM) 84-HUD - 

USA SEULEMENT

"Empêcher  MAISON  incendies"

 Installer et utiliser uniquement en conformité avec installation et 

d'utilisation les instructions du fabricant et les codes locaux. En l'absence de codes locaux, l'installation doit 

satisfaire aux exigences minimales de la norme NFPA 211 aux Etats-Unis. Reportez-vous aux instructions 

du fabricant et les codes locaux pour les précautions nécessaires pour faire passer la cheminée à travers 

un mur ou un plafond combustible.

Ce poêle à bois doit inspection périodique et la réparation pour un fonctionnement correct. Consultez le 

manuel du propriétaire pour plus d'informations. Ce est contre les règlements fédéraux pour faire fonctionner 

ce poêle à bois d'une manière incompatible avec les instructions d'utilisation dans le manuel du propriétaire.

AVERTISSEMENT: POUR maisons préfabriquées:

 (États-Unis uniquement) Ne pas installer l'appareil 

dans une chambre à coucher. Une entrée d'air extérieur doit être fournie. L'intégrité structurale du sol, les 

murs et le plafond de la maison préfabriquée doit être maintenue.

Tuyau de raccordement de fumée doit être de 6 "de diamètre, en acier au minimum 24 MSG bleu. 

Cheminée doit être construite l'usine 103HT ou la construction de maçonnerie. Contactez Immeuble Local 

ou fonctionnaires incendie au sujet des restrictions et l'inspection d'installation dans votre région.

NE PAS brancher l'appareil à une cheminée desservant un autre APPAREIL.

Pour une utilisation avec Solid combustible bois Seulement, Ne pas brûler de charbon.

Émissions certifiés EPA: 3,67 g / h

Type de carburant: Cordon bois

NE SURCHAUFFEZ - Si le connecteur chauffe ou de la cheminée rougeoie, vous surchauffez.

Facultatif Blower Harman # 1-00-856082: Note électrique 115 VAC, 60Hz, 1AMP maximum

Route cordon électrique de l'appareil.

FONCTIONNER UNIqUEMENT AVEC LES PORTES FERMéES

Remplacer le verre seulement avec de la céramique 5mm, disponible chez votre revendeur.

Plancher combustible doit être protégé par un conseil 0.45R foyer approuvé.

L'appareil doit être installé avec les jambes attachées. Ne pas obstruer le flux d'air sous l'appareil.

DANGER: risque d'incendie ou d'explosion - Ne pas brûler de déchets, de l'essence, vidanger l'huile 

ou d'autres liquides inflammables.

AVERTISSEMENT:  Risque  d'incendie,  ne  pas  fonctionner  avec  chargement  de  combustible  ou 

d'enlèvement de cendres portes ouvertes.

Ne  pas  stocker  carburants  ou  de  combustibles  dans  les  dégagements  marqués.  Inspectez 

et  cheminée  propre  et  le  connecteur  régulièrement  -  Dans  certaines  conditions  d'utilisation, 

l'accumulation de créosote peut se produire rapidement.

Le Bypass amortisseur doit être ouvert avant d'ouvrir ne importe quelle porte de charge ou de la 

cendre.

Ne pas installer une grille ou autrement surélever le feu.

MODEL / MODÈLE: “TL2.6” Woodburning Stove

Room Heater Solid Fuel Burning Type

SUITABLE FOR MOBILE-HOME INSTALLATION 

(USA ONLY)

352 Mountain House Road

Halifax, PA 17032

ECO: 
PARt # / REv:  3-90-00857_RevD
ORiginAtOR:  Spidle
DAtE:  04/15
LAbEL SizE:  11.5 in. x 6.5 in.
LOCAtiOn: 

Rear of Stove

CLASS: 
ADHESivE: 

468

MAtERiAL: 

MEtAL

ink: bLACk
OvERCOAt:

LAbEL tiCkEt

(4) Hole Size = .187

Corners .062

May be burned as a fireplace with “Cozy Screen” Part# 3-40-06960 in place over door opening. Otherwise, doors must remain closed during operation

Peux fonctionner comme un foyer avec la pièce no. 3-40-06960 ‘’ Cozy Screen ‘’ placée au dessus  de l’ouverture de la porte. Autrement , les portes doivent demeurer fermées durant  le fonctionnement.

US ENVIRONMENTAL PROTECTION AGENCY

Certified to comply with 2015 particulate emission standards. Not approved for sale after May 15, 2020.

Certifié conforme aux normes 2015 d’émission de particules. Non approuvé pour la vente après le 15 mai 2020.

ATTENTION:

CHAUD LORS DU FONCTIONNEMENT- NE TOUCHEZ PAS 

L’APPAREIL-GARDEZ LES ENFANTS ET LES VÊTEMENTS ÉLOIGNÉS- TOUT CONTACT 

PEUT ENTRAÎNER DES BRÛLURES DE LA PEAU. RÉFÉREZ-VOUS À LA PLAQUE 

SIGNALÉTIQUE ET AU MODE D’EMPLOI. GARDEZ LE MOBILIER ET LES AUTRES 

MATÉRIAUX COMBUSTIBLES BIEN À L’ÉCART DE L’APPAREIL.

CAUTION:

HOT wHILE  IN  OPERATION-  DO  NOT  TOUCH- 

kEEP CHILDRENAND CLOTHING AwAy- CONTACT MAy CAUSE SkIN 

BURNS- SEE NAMEPLATE AND INSTRUCTIONS. kEEP FURNISHINGS 

AND OTHER COMBUSTIBLE MATERIALS A CONSIDERABLE DISTANCE 

AwAy FROM THE APPLIANCE

REFER TO PRODUCT MANUAL FOR CLEARANCES WITH ADDITIONAL VENT CONFIGURATIONS.

Veuillez vous référer au manuel d’instruction pour informations additionnels pour la configuration de 

la ventilation.

Floor protection must be a non-combustible material. Must also be 

placed under any horizontal sections of flue connector, extending 

2” (51mm) beyond each side of the connector. / Pour protéger le 

plancher, il faut sous le poêle un matériau. Qui doit aussi être placé 

sous les parties horizontales du tuyau de raccord à la cheminée et 

s’étendre à 51 mm (2 po) au-delà de lateral du tuyau.

When  installed  with  the  optional  leg  kit,  The  bottom  heat  shield 

must be in place, and the area under the appliance kept clear. Que 

installé avec le kit de jambe optionnel, le bouclier de chaleur de 

fond doit être dans l’endroit et la région sous l’appareil gardé clair.

BARCODE LABEL

008

Serial No.

N

o

 de série:

Rev D

P.N. 3-90-00857

Date of Manufacture / Date de fabrication:

2015   2016   2017   JAN   FEB   MAR   APR   MAy   JUN   JUL   AUG   SEP   OCT   NOV   DEC

Manufactured by / Fabriqué par: Hearth and Home Technologies 352 Mountain House Road, Halifax PA 17032

A

 = Unit to Sidewall  

17”

b

 = Unit to Backwall  

17”

C

 = Chimney Connector to Sidewall 

27”

D

 = Chimney Connector to Backwall 

20”

E

 = Unit to Adjacent Wall  

14-1/2”

F

 = Chimney Connector to Adjacent Wall  23”

CLEARANCE TO COMbUSTIbLE SURFACES

A

 = Entre le mur lateral et l’appareil 

432mm

b

 = Entre le mur arriereet l’appareil 

432mm

C

 = Entre le tuyau et le mur lateral 

686mm

D

 = Entre le tuyau et le mur arriere 

508mm

E

 = Entre le mur adjacent et l’appareil 

368mm

F

 = Entre le tuyau et le mur adjacent 

584mm

CLEARANCE TO COMbUSTIbLE SURFACES

D

b

C

A

E

F

Made  in  U.S.A.  of  US  and  imported  parts.  /  Fabriqué  aux  États-Unis-

d’Amérique par des pièces d’origine américaine et pièces importées.

USA

8”

8” (200mm)

CAN 

200mm

18”

457mm

Hearth & Home Technologies welcomes you to our tradition of excellence! By choosing a Harman appliance, you have become 

part of our commitment to meeting the heating needs of consumers with the most distinctive, powerful and responsible home 

heating products available. 
With it's durable steel-body construction, the TL2.6 takes advantage of Harman’s 30+ years of stove design, technology and 

manufacturing. The Firedome Plus secondary combustion system provides for super-clean burning and minimal maintenance. 

The top-loading feature makes for more convenient loading, with enough fuel for an all day burn.
We wish you and your family many years of enjoyment in the warmth and comfort of your hearth appliance.
Thank you for choosing Harman.

This Label is located on the rear of the appliance. It contains important safety test information as well as the clearances to 

combustible materials. The label also contains the appliance serial number. For your records, copy your serial number and 

purchase date here.

Serial #: ________________________  

 

Date of Purchase: ________________________

SAMPLE LABEL

Summary of Contents for TL 2.6

Page 1: ...PERMITS HOT WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL IT IS COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS KEEP CHILDREN AWAY CAREFULLY SUPERVISE CHILDREN IN SAME ROOM AS FIREPLACE ALERT CHILDREN AND ADUL...

Page 2: ...le ou d autres liquides inflammables AVERTISSEMENT Risque d incendie ne pas fonctionner avec chargement de combustible ou d enl vement de cendres portes ouvertes Ne pas stocker carburants ou de combus...

Page 3: ...le Home Installation 21 Section 7 Appliance Set Up A Outside Air Attachment 22 B Leveling the Appliance 22 C Optional Cooking Grill 22 D Optional Blower Kit 23 E Brushed Stainless Trim Option 23 Secti...

Page 4: ...Certified to comply with 2015 particulate emission standards Not approved for sale after May 15 2020 MODEL TL2 6 Woodburning Stove LABORATORY OMNI Test Laboratories Inc REPORT NO 135 S 30b 6 2 TYPE S...

Page 5: ...dows or doors 2 Make sure the stove doors and lid are closed and latched 3 Check stove for smoking or puffing condition Open by pass and increase air flow to firebox if needed 4 Check chimney for poss...

Page 6: ...appliance Certain conditions can create negative pressure within the dwelling When this occurs you may have trouble operating the wood stove Worse yet it may be strong enough to allow smoke leakage fr...

Page 7: ...ff the rear shield by removing the four bolts near each corner of the safety label The flue cover plate and the flue collar have the same 2 bolt pattern Switch the two of them by removing the nuts fro...

Page 8: ...ey meets the minimum height requirements 10 All labels and hang tags have been removed from the glass 11 All plated surfaces have been wiped clean if applicable 12 The optional air distribution blower...

Page 9: ...nce Dimensions Section 4 Dimensions and Clearances 23 15 16 607mm 34 7 8 885mm 36 11 16 935mm 25 7 8 657mm 34 9 16 888mm 32 3 4 832mm 25 7 8 657mm Outside Air Kit 9 5 16 236mm 29 1 2 749mm C L Outside...

Page 10: ...d Fuel Burning Appliances Vertical Venting Configuration Location Single Wall Pipe Double Wall Pipe A Unit to Side Wall 17 432mm 15 381mm B Unit to Back Wall 17 432mm 15 381mm C Vent Pipe to Side Wall...

Page 11: ...rances for Solid Fuel Burning Appliances for clearance from the top of the unit to ceiling This unit was not tested for installation into an Alcove Follow NFPA 211 Table 13 6 1 Clearances for Solid Fu...

Page 12: ...of the stove A corner installation is one in which the back of the stove is positioned diagonally across a corner of the room Each installation requires its own set of clearances For corner installat...

Page 13: ...e collar opening which is 6 inches Do not use makeshift compromises No part of the chimney connector may pass through an attic or roof The Chimney Connector Shall Not Pass Through an Attic or Roof Spa...

Page 14: ...olid fuel chimneys extend 3 ft 0 9m above the highest point at which they exit from the roof Then the chimney must extend 2 ft 0 6m above the highest point within a 10ft 3m radius Thus the 3 foot 2 fo...

Page 15: ...Protection in this section Since many fireplaces have exposed wooden mantels and trim pay special attention to the clearances necessary to these materials If your fireplace chimney is behind a combus...

Page 16: ...led Space a Floor or Ceiling Chimney Connector Minimum air space with chimney listing Chimney support Attic radiation shield Chimney sections Chimney cap Storm collar Roof flashing Roof radiation shie...

Page 17: ...ce Closet or Similar Concealed Space a Floor or Ceiling Minimum clearance to unprotected ceiling 15 Chimney connector sealed at thimble Flue liner with required air space Minimum of three sheet metal...

Page 18: ...of Space Closet or Similar Concealed Space a Floor or Ceiling Combustible Floor Airtight insulated clean out Flue liner with required air space Floor Protection Stainlesssteel chimney connector must e...

Page 19: ...Concealed Space a Floor or Ceiling Combustible Floor UL1777 Stainless steel liner system or other approved lining system Floor Protection Follow liner manufacture s instructions on insulation and supp...

Page 20: ...y connector to uprotected ceiling 15 Flue liner with required air space Listed or approved thimble assembly 1 Clearance for exterior chimney or 2 clearance for interior chimney and 2 clearance for NFP...

Page 21: ...inal cap with spark arrestor 7 Use silicone to create an effective vapor barrier at the location where the chimney or other component penetrates to the exterior 8 Installation shall be in accordance w...

Page 22: ...ide the other end of the metal intake flex pipe into the stub on the rear of the stove and secure it with aluminum tape This air intake will supply outside air for the secondary combustion 7 Secure th...

Page 23: ...eces Load door trim Ash lip trim and the Ash door frame To install the load door trim it is best to remove the door by lifting from the hinges Lay the door down flat on it s face Drill the dimpled hol...

Page 24: ...open the ash door lift up the handle and pull out Close the door by pushing in and pushing the handle all the way down Top Load Door To open the top load door open the bypass damper and then lift to...

Page 25: ...bustion air enters at the bottom front of the stove where it travels upward through channels at either side of the front door From the manifold located above the front door it is directed into the fir...

Page 26: ...e loading door s Allow this start up fire to burn for a few minutes keeping the bypass damper open Add about five more pieces of wood in the 2 to 3 inch 50 80mm size range making sure that the fuel be...

Page 27: ...of 900 F 1100 F indicate that the stove is normally ready for Firedome mode With the Firedome engaged temperatures of 500 F 800 F indicate the unit is burning properly and no adjustment is necessary...

Page 28: ...years of trouble free service Contact your dealer to answer questions regarding proper operation trouble shooting and service for your appliance Visit www harmanstoves com to find a dealer We recommen...

Page 29: ...lass should be obtained only through your Harman dealer To replace a broken glass first be sure to carefully remove the broken glass and any remaining shards or pieces With the door laying on a flat s...

Page 30: ...ousing Alternately with some minor disassembly you can use a vacuum and or brush to clean the blower wheel Reinstall the blower and tighten the four bolts securely 5 Chimney Connector Frequency As nec...

Page 31: ...d Wood Only Harman TL2 6 Owner s Manual_R25 2011 ___ 09 15 Variable Speed Switch Power Cord Blower Thermostat Grounded to housing Black Wire White Wire 2 1 TL2 0 TL2 6 Optional Blower Kit 1 00 856002...

Page 32: ...9 15 Service Parts TL2 6 W Pedestal Beginning Manufacturing Date Sept 2011 Ending Manufacturing Date Active Part number list on following page Wood Stove 1 90 857000 1 2 3 1 4 5 6 7 8 9 10 11 13 12 14...

Page 33: ...Damper gasket 30 ft 1 00 00888 Y Damper Shaft Retainers Hardware Set of 2 1 00 249145 Y Damper Only 1 10 249107 Gasket 1 Single Ply Tape 10 Ft 1 00 88100 Y 5 Firedome Plus Combustion Package with Gask...

Page 34: ...an 1 10 857002A Y 22 Combustion shoe brick 3 40 00100 Y Shoe brick gasket 3 44 06951 Y 23 Side brick insulation Qty 2 req 3 40 857054 Y 24 Right side panel painted 2 00 857021B Y 25 Heat shield mounti...

Page 35: ...30 1110 100 Y Cap Screw 5 16 18 x 1 2 Grade 5 Zinc Plated Hex Pkg of 50 3 30 1122 50 Y Cap Screw 1 4 20 x 3 8 Grade 5 Zinc Hex Pkg of 25 3 30 1106 25 Y Cap Screw 5 16 18 x 3 4 Grade 8 Plain Finish Hex...

Page 36: ...Service Parts TL2 6 w Legs Beginning Manufacturing Date Sept 2011 Ending Manufacturing Date Active Part number list on following page Wood Stove 1 90 858000 1 08 15 1 2 3 7 6 5 4 8 9 10 11 12 13 14 1...

Page 37: ...Wooden handle for damper w hardware Pkg of 2 1 00 00249 Y 6 Damper Elbow painted 3 50 00500S Y 7 Damper shaft bushing plates w hardware Inner outer 1 00 856061 Y 8 Damper rod weldment 1 10 856011W Y...

Page 38: ...ntrol weldment 1 10 856004W Y 22 Air slide 1 10 856003W Y 23 Shoe brick gasket 3 44 06951 Y 24 Bottom Heat Shield 1 00 857056 25 Queen Ann Leg painted w Hardware Qty 4 req 1 00 7000551 Y 26 Right side...

Page 39: ...1110 100 Y Cap Screw 5 16 18 x 1 2 Grade 5 Zinc Plated Hex Pkg of 50 3 30 1122 50 Y Cap Screw 1 4 20 x 3 8 Grade 5 Zinc Hex Pkg of 25 3 30 1106 25 Y Cap Screw 5 16 18 x 3 4 Grade 8 Plain Finish Hex P...

Page 40: ...In the case of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distrib...

Page 41: ...ED ABOVE WARRANTY EXCLUSIONS This warranty does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surf...

Page 42: ...Save These Instructions 3 90 08570 Harman TL2 6 Owner s Manual_R25 2011 ___ 09 15 Service Maintenance Log Date Of Service Performed By Description Of Service...

Page 43: ......

Page 44: ...________________________________________________________________________________ ________________________________________________________________________________ _____________________________________...

Reviews: