Harman® • PF-120 Owner’s Manual_R3 • 2014 -___ • 10/14
2
3-90-08120c
OMNI-Test Laboratories, Inc.
Report #/Rapport #135-S-02b-2
Certified for U.S.A. and Canada
Certifié pour les
é
tats-Unis et le Canada
BARCODE LABEL
008
Serial No.
N
o
de série:
PF-120
LISTED PELLET FUEL CENTRAL OR SUPPLEMENTARY FURNACES FOR RESIDENTIAL USE
APPAREIL DE ChAUFFAgE CENTRAL OU SUPPLéMENTAIRE ENREgISTRé DE gRANULéS
COMbUSTIbLES POUR USAgE DANS LES RéSIDENCES
Tested January 2013 to UL 391-2010, ASTM E 1509-04, and CSA-B366.1-11
Install and use only in accordance with the manufacturer’s installation/operting
instructions. Refer to authorities having jurisdiction for proper installation. Contact
local building or fire officials about restrictions and installation inspection in your
area.
If there are no applicable local codes, follow ANSI/NFPA 211 and CAN/CSA B365.
Special precautions are required for passing the chimney through a combustible
wall or ceiling.
Inspect and clean exhaust venting system frequently in accordance with the
manufacturer’s instructions. Use a 4” diameter type “PL” venting system.
A Harman PF-120 may be connected to an existing furnace or heat pump duct
system.
Room Heater, Pellet Fuel-Burning Type, Also for Use in Mobile Homes
For use with Pelletized wood Fuel only.
Testé en January 2013 à UL 391-2010, ASTM E 1509-04, and CSA-B366.1-11
Installez et utilisez en accord avec les instructions d’installation et d’opération
du fabricant. Référez-vous à des professionnels avec autorité dans l’installation.
Contactez le bureau de la construction.ou le bureau des incendies au sujet des
restrictions et de l’inspection dans votre voisinage.
S’il n’y a pas de codes locaux, suivez alors ANSI/NFPA211 et CAN/CSA B365.
Prenez des précautions spéciales lorsque vous faites passer une cheminée à
travers un mur ou un plafond combustibles. Inspectez et nettoyez le sustème de
ventilation fréquemment en accord avec les instructions du fabricant. Utilisez un
système de ventilation de 4” de diamètre de type “PL”.
Une Harman PF-120 peut être connecté à une fournaise ou un système de pompe
de chauffage déjà existants.
Appareil de chauffage aux granules, type de chauffage à combustible, également
destinés aux maisons mobiles
FonCtionne eXClusiVeMent AVeC des GrAnules de Bois.
Combustibles to Filter Box on Appliance
Combustibles to Connector Pipe
Combustibles to Appliance
Supply Air Plenum to Ceiling
Supply Air Plenum to Combustible Chase
Appliance Body to Ceiling
Combustibles from Stove Front
Clearances to Combustibles/Espaces Libres aux Combustibles
1” (25 mm)
*3” (76 mm)
12” (305 mm)
1” (25 mm)
1” (25 mm)
28” (711 mm)
36” (914 mm)
Des combustibles à la boîte de filtration de l’appareil
Des combustibles au tuyau connecteur
Des combustibles à l’appareil
Provision d’air plénum au plafond
Provision d’air plénum au châssis du combustible
De l’appareil au plafond
Des Combustibles au devant du poêle
*At 16” of pipe length distance from the flue collar while maintaining listed clearances from appliance body.
Un tuyau de grandeur de distance de 16” de l’ouverture du ventilateur doit être en accord avec l’espace libre mentionné de l’appareil même.
Thermostat / Thermostat
Datacom Wire / Fil Datacom
Fan Control High Limit / Contrôle du ventilateur haute limite
Fire Brick / Brique de feu
Heat Exchanger Baffles / Déflecteurs d’échange de chaleur
Essential parts and subassemblies provided for field assembly are as follows /
Pièces essentielles et sous-assemblée procurées pour l’assemblage sont les suivantes:
Burnpot Scraper / Grattoir de la chaudière de chauffage
1638 CFM Blower / Ventilateur CFM 1638
Return Air Filter Box / Boîte de filtration pour retour d’air
Ash Pan / Bassin des cendres
date of Manufacture / date de fabrication
2014 2015 2016 JAn FeB MAr APr MAy Jun Jul AuG seP oCt noV deC
Made in the U.S.A. / Fait aux
é
tats-Unis
Do Not Remove or Cover This Label/Ne pas enlever ou recouvrir cet étiquette
Manufactured by/Fabriqué par: hearth & home Technologies, Inc.
352 Mountain house Road - halifax, PA 17032
do not ConneCt this unit to A ChiMney Flue serVinG
Another APPliAnCe
wArninG!
DO NOT operate with fire chamber or ash removal doors
open. DO NOT store fuel or other combustible material within
installation clearance area.
CAution!
Hot while in operation.
DO NOT touch. Keep children, clothing, furniture and other combustible
material out of the installation clearance area.
DO NOT connect this unit to a chimney flue that serves another appliance.
Flooring must be a non-combustible material covering the installation
clearance area, and 18” in front of, and 8” to either side of the fuel loading
doors.
In the event of loss of electrical power:
Consult owner’s manual for restarting your furnace after power is restored.
U.S. ENVIRONMENTAL PROTECTION AGENCY
This model is exempt from EPA certification under 40 CFR 60.531
by definition [Wood Heater (A) “air-to-fuel ratio”].
ne PAs ConneCter Cet APPAreil à un tuyAu de CheMinée
serVAnt un Autre APPAreil
Attention!
Ne pas opérer si la porte du combustible ou la porte de la cuvette
des cendres sont ouvertes. Ne pas placer le combustible et les
matières combustibles à l’intérieur de l’espace désignée pour
l’installation.
Attention!
Chaud lors de l’opération.
NE PAS toucher. Gardez les enfants, les vêtements, les meubles et les
matériaux combustibles loin de l’espace désignée pour l’installation.
NE PAS connecter cet apareil à un tuyau de checminée servant un autre
appareil.
Le plancher de l’espace désigné pour l’installation doit ê fait de matière non-
combustible, de 18” en avant, et de 8” de chaque côté des portes d’entrée du
combustible.
Dans le cas d’un manque d’électricité:
Consultez le manuel du propriétaire pour remettre la fournaise en marche
lorsque l’electricité ést revenue.
Rev A
P.n. 3-90-08121
Harman PF120 Pellet Furnace
Label measures: 10" high X 6.5"wide
Model
Modèle
Fuel
Combustible
Chimney Connector Size
Grandeur du Tuyau de Cheminée
BTUH/Kw Input Pellet
Rendement des Granulés BTUH/Kw
Electrical Rating
Classification
é
lectrique
Maximum Overcurrent Protection
Protection Maximum du Courant
PF-120
Pellet
Granulés
4”
132,000 BTUH (39 Kw)
120V, 9.3A, 60 Hz
20 AMP
Door
opening
side of the
furnace
18”
8”
8”
48”
52”
fLOOR
p
ROT
ec
TO
R
Floor Protection
18”
12”
18”
36”
1”
18”
36”
18”
12”
1”
Listing Label Information/Location
A. Congratulations
Congratulations on selecting a Harman® PF-120 Pellet
Furnace. The Harman® PF-120 Pellet Furnace you have
selected is designed to provide the utmost in safety, reliability,
and efficiency.
As the owner of a new pellet furnace, you’ll want to read and
carefully follow all of the instructions contained in this owner’s
manual. Pay special attention to all cautions and warnings.
This owner’s manual
should be retained for future reference.
We suggest that you keep it with your other important
documents and product manuals.
Your new Harman® PF-120 Pellet Furnace will give you
years of durable use and trouble-free enjoyment. Welcome
to the Harman® family!
The model information regarding your specific
furnace can be found on the rating plate usually
located in the area below the hopper.
Read this manual before operating this appliance.
Please retain this Owner’s Manual for future reference.
Read the Installation Manual before making any installation or finishing changes.
1
welcome
Brand: ________________________________________________ Model Name: ___________________________
Serial Number: __________________________________________ Date Installed: __________________________
Appliance Information:
Local Dealer Information
DEALER:
Fill in
your name, address,
phone and email
information here and
appliance information
below.
Dealer Name: ________________________________________________________
Address: ____________________________________________________________
____________________________________________________________
Phone: _____________________________________________________________
Email: _____________________________________________________________
Serial Number
Model Name