Harman® • PF-120 Owner’s Manual_R3 • 2014 -___ • 10/14
11
3-90-08120c
4
Operating Instructions
B. Fire Characteristics
A properly adjusted fire has a medium active flame pattern
that extends out of the burn pot approximately 6 inches
(152mm).
C. Feed Rate Adjustment Instructions
The feed adjustment control is factory set at #4, and should
be adequate for most fuels.
However, if the flame height is too high or too low, you will
need to adjust the feed rate. Wait until the appliance has been
burning for 15 minutes before making your adjustments and
allow 15 minutes for feed adjustment to take effect.
A. Starting Your First Fire
1. The wall control is required for proper operation of this
appliance in “Automatic” mode. At this time, fill the hopper
with pellets, insure the control is set to “OFF”. Figure 4.1.
Plug the power cord into a properly grounded, nearby
outlet.
2. Once power is present, the unit it will run through a quick
diagnostics test to insure the control is operating properly.
This is normal.
3. For your first fire it may be necessary to purge the auger
system by putting the feed adjuster knob to “Test” prior
to starting the unit. Figure 4.2. This insures that plenty of
fuel enters the burn pot for proper ignition.
Figure 4.4
Figure 4.1
Figure 4.2
Figure 4.3
Odors and vapors released during initial operation.
• Curing of high temperature paint.
• Open windows for air circulation.
Odors may be irritating to sensitive individuals.
CAUTION
!
CAUTION
!
DO NOT BURN GARBAGE, GASOLINE, DRAIN OIL,
OR OTHER FLAMMABLE LIQUIDS.
CAUTION
!
HOT wHILE IN OPERATION. DO NOT TOUCH.
KEEP CHILDREN, CLOTHING, FURNITURE, AND
OTHER COMBUSTIBLE MATERIAL OUT OF THE
INSTALLATION CLEARANCE AREA.
WARNING
!
DO NOT OPERATE wITH HOPPER OR ASH REMOVAL
DOORS OPEN.
WARNING
!
DO NOT STORE FUEL OR OTHER COMBUSTIBLE
MATERIAL wITHIN INSTALLATION CLEARANCE
AREA.
FOR SAFETY KEEP FIRING AND ASH PIT DOORS
TIGHTLY CLOSED.
OPERATE THE ELECTRIC FURNACE PERIODICALLY
TO ENSURE THAT IT wILL OPERATE SATISFACTORILY
wHEN NEEDED.
4. Flip toggle switch to desired mode “auto or manual”. Figure
4.3. Set feed adjuster knob to desired setting and turn
mode dial to “Automatic” or “Service” Figure 4.4. Feed
rate of #4 is a good starting point. Adjustments may need
to be made depending on fuel quality and/or heat output
desired.
Note:
The igniter will not come on until the initial
feed charge is complete.
5. The fuel feed system and the igniter should now be on (If
unit is set to auto mode).
6. Once the appliance has ignited, let it burn for approximately
7-10 minutes. After this time, the igniter light should turn
off and the unit should begin to operate per the settings
at the control.
CAUTION
!
DO NOT USE CHEMICALS OR FLUIDS TO START FIRE