Martin VDO Atomic Bold user guide
13
Physical installation
Warning!
Read ‘Safety information’ on page 8 before installing the fixture.
Warning! The safety and suitability of lifting equipment, installation location,
anchoring method, mounting hardware and electrical installation are the
responsibility of the installer. All local safety regulations and legal requirements
must be observed when installing and connecting the VDO Atomic Bold fixture.
Installation must be carried out by qualified professionals only.
Contact your Martin supplier for assistance if you have any questions about how to install this
product safely.
Fixture location
The VDO Atomic Bold Fixture is fully IP65 rated and may be used indoors or in a temporary
outdoor location.
Observe the following limitations in selecting a location:
x
Respect the limitations listed under Safety information’ on page 8.
x
Certified for damp locations in US/Canada.
x
Do not locate the fixture in an unventilated space.
Ways of mounting the fixture
Warning!
All fasteners used to mount VDO Atomic Bold fixtures or arrays of
fixtures must be strong enough to hold the fixtures safely. Install a washer directly
under the head of each fastener when anchoring the mounting bracket to the
installation surface.
The fixture has a number of mounting options:
x
Via the hanging bracket to a truss or surface
x
Floor mount using the integrated floor mounting bracket
x
A VDO Atomic Half Coupler may be attached directly to one of the interlock slots on the
fixture (without the hanging bracket)
x
Multiple fixtures may be interlocked together using the slide-in Interlock Coupler. A
maximum of 4 fixtures may be interlocked in a column. When interlocking fixtures
horizontally, a rigging clamp must be used for every fixture or every column to support
the array.
x
A Pivot Interlock Coupler is available which couples fixtures at any multiple of 15
degrees. This allows circles or other shapes of fixtures to be created.
x
An Interlock Adaptor is available which attaches to one of the interlock slots enabling
you to mount a single VDO Atomic Bold on a suitable stand with standard 5/8 in. or M8
thread.
x
A Double Width Bracket is available to join 2 fixtures in a 2-lite which can then be
attached to a truss or surface.
x
A Spigot Adapter is available to attach a fixture to standard spigot-compatible
accessories such as floorplates and stands.
x
VDO Atomic Bold fixtures can also be combined with VDO Atomic Dot fixtures in a
mixed array. In such case a VDO Atomic Bold Interlock Doubler is used to connect two
VDO Atomic Dot fixtures above, below, left or right of a VDO Atomic Bold fixture.
x
Safety bonds must be fitted to each fixture, even when fixtures are interlocked, using
the safety bond attachment point on the rear.