Martin
®
ERA 700 Performance IP User Manual Rev. C
31
Control menus
Default settings are given in
bold print
.
Menu level 1
Menu level 2
Menu level 3
Notes
DMX SETUP
DMX ADDRESS
1
- 472
DMX address
(default address = 1)
.
The DMX address range is limited so
that the fixture will always have enough
DMX channels within the 512 available.
CONTROL MODE
BASIC
Basic DMX control mode
EXTENDED
Extended DMX control mode
PERSONALITY
NET ADDRESS
UNIVERSE
Set fixture’s network addressing data
IP ADDRESS
SUBNET MASK
NET SWITCH
OFF
Network protocol auto-detect on
ON
PAN INVERSE
NO
Inverse DMX pan
control: right → left
YES
TILT INVERSE
NO
Inverse DMX tilt control: down → up
YES
PAN/TILT SPEED
FAST
Adjust speed of pan and tilt movement
SLOW
DIMMER CURVE
LINEAR
Optically linear dimming curve
SQUARE LAW
Square law dimming curve
INV SQ LAW
Inverse square law dimming curve
S-CURVE
S-curve (fixture emulates incandescent
lamp voltage linear RMS dimming
curve)
DIMMING SPEED
FAST
Snap dimming (fast dimmer speed)
SLOW
Fade dimming (slow dimmer speed)
NO DATA MODE
BLACKOUT
If data connection is lost, fixture will
blackout
HOLD
If data connection is lost, fixture holds
latest received data value at all
channels
SCENE CATCH
SCENE CATCH RECORD
Saves all current DMX values as
playback scene
SCENE CATCH ON
Sets fixture to run currently saved
playback scene after power cycle or
reset. Any new DMX input disables
scene playback until next power cycle.
SCENE CATCH OFF
Disables playback scene functionality