Martin
®
ERA 700 Performance IP User Manual Rev. C
27
•
If you apply a
Display Errors
PID, the fixture
’s control panel display wakes up and displays any
error messages, even if the display is blacked out.
•
The
Auto Empty Water
PID enables the automatic de-humidifying function.
•
The
Outdoor Actions
PID lets you run the forced de-humidifying sequence.
•
Applying a
Fan Clean
PID activates a sequence that runs fans at full speed in order to remove dust
and dirt. This function will not clean fan blades completely, but it can remove the worst of any
accumulated dust.
RDM functions
ERA 700 Performance IP fixtures support the following RDM PIDs:
PID
Name
Description
GET SET
Device discovery
0x0001
DISC_UNIQUE_BRANCH
Fixture discovery
N/A
N/A
0x0002
DISC_MUTE
Fixture discovery
N/A
N/A
0x0003
DISC_UN_MUTE
Fixture discovery
N/A
N/A
Device information
0x0060
DEVICE_INFO
Get basic fixture info
✓
0x0080
DEVICE_MODEL_DESCRIPTION
Product name
✓
0x0081
MANUFACTURER_LABEL
Manufacturer name
✓
0x0082
DEVICE_LABEL
Info label (user-
settable)
✓
✓
0x8003
FIXTURE_ID
Fixture number (user-
settable)
✓
✓
0x8700
SERIAL_NUMBER
Fixture serial number
✓
0x00C0
SOFTWARE_VERSION_LABEL
Firmware version
✓
0x0200
SENSOR_DEFINITION
Sensor description
✓
0x0201
SENSOR_VALUE
Sensor value
✓
✓
0x0400
DEVICE_HOURS
Fixture hours (non-
resettable)
✓
✓
0x0405
DEVICE_POWER_CYCLES
Fixture power cycles
(non-resettable)
✓
✓
DMX setup
0x00E0
DMX_PERSONALITY
DMX mode
✓
✓
0x00E1
DMX_PERSONALITY_DESCRIPTION
DMX mode details
✓
0x00F0
DMX_START_ADDRESS
DMX start address
✓
✓
0x0121
SLOT_DESCRIPTION
DMX channel details
✓
Ethernet setup
0x0700
LIST_INTERFACES
List Ethernet ports
✓
0x0701
INTERFACE_LABEL
Name of Ethernet
port
✓
0x0702
INTERFACE_HARDWARE_ADDRESS_TYPE1
MAC address of
Ethernet Port
✓