VENTING
Montigo Direct Vent
Description Order Code
HORIzONTAL TERMINATIONS
3" termination with no mounting frame (male connector). ..................... Pto3
(use with Msr or Mosr).
3" termination & mounting frame (male connector). ............................. Pto3F
VERTICAL TERMINATION
termination for vertical installations (male connector) ........................... PvtK1
includes PXt-10 adaptor (for straight, vertical installations).
VENT PIPES
Note:
For all Rear Vent applications with no vertical rise, there is a maximum horizontal run
of 20".
Extensions
5" rigid section (female/female connectors) .......................................... PXt5
10" rigid section (female/female) ......................................................... PXt10 .
20" rigid section (female/female) ......................................................... PXt20
12" rigid section (female/male connectors) .......................................... PeXt1
24" rigid section (female/male) ........................................................... PeXt2
36" rigid section (female/male)............................................................ PeXt3
48" rigid section (female/mal............................................................... PeXt4
72" rigid section (female/male) ........................................................... PeXt6
Flex Sections
12" flex section (female/female connectors) ........................................ PFL1
18" flex section (female/female........................................................... PFL18
24" flex section (female/female) ......................................................... PFL2
36" flex section (female/female) ......................................................... PFL3
48" flex section (female/female) ......................................................... PFL4
Elbows
45° elbow (female/male connectors) .................................................. PeL45FM
90° elbow (female/female connectors) ................................................PeL90F/F
90° elbow (male/male) ......................................................................PeL90M/M
90° elbow (female/male) ...................................................................PeL90F/M
clearance reducing sleeve ...............................................................crs30
Vent Connector
4" length vent connector (male/male connectors) ................................. Pva
Vertical Vent Reducer
10" length, reduces vertical 5"/8" venting to 4"/7" (male/female connectors) Pva5487
TERMINATION FRAMES
Siding or Stucco Frame
..................................................................Msr
used for easy installation of termination.
Siding or Stucco Can
......................................................................Mosr
used to provide installation of termination from the inside of the building.
Brick Siding Can
used for installation of termination on brick wall.
4" depth ............................................................................................ Bsr-4
6" depth .............................................................................................Bsr-6
Premium Series Direct Vent (5"/8")