Instruction Manual | 5
CE-Series Universal Control Extenders
Overview
The CE-Series of Universal Control Extenders provide port expansion over Ethernet for any control system. The HControl
protocol provides a simple path and value approach to actuating the device functions. The use of the CE-Series Control
Extender with other HControl-aware Harman products makes a seamless extension of those systems. The Ethernet
connectivity helps break distance limitations and provide flexibility of installation.
CE-Series Control Extender boxes
Name
SKU
Description
Page Reference
CE-IRS4
AMX-CEB001
Control Extender – 4 IR
CE-REL8
AMX-CEB002
Control Extender – 8 Relay
CE-COM2
AMX-CEB003
Control Extender – 2 COM
CE-IO4
AMX-CEB004
Control Extender – 4 IO
Common Features
CE-Series Common Features
D
IMENSIONS
1" x 4 1/16" x 4 3/32"
2.5 cm x 10.3 cm x 10.4 cm
(1/4 RU Width x <1 RU Height)
W
EIGHT
1lb
454 g
P
OWER
R
EQUIREMENTS
PoE – 802.3af Class 0 Maximum
15.4W
CE-IRS4
2.6W
CE-REL8
4.1W
CE-COM2
5.6W
CE-IO4
14.7W
Enclosure
Powder-coated steel w/ grey matt finish
Certifications
FCC Part 15 Class B, CE, and IEC 60950
Environmental
Requirements
Operating Temperature
:
0° C (32° F) to 40° C (104° F)
Storage Temperature
:
-10° C (14° F) to 60° C (140° F)
Operating Humidity
:
5% to 85% RH (non-condensing)
Heat Dissipation (Typical)
: 36.9 BTU/hr
Designed for indoor use only.
F
RONT
P
ANEL
C
OMPONENTS
ID Pushbutton
S
tatus LED
A multi-colored LED indicating the device status (see fig ???)
L
/A LED
A network link/activity light
R
EAR
P
ANEL
C
OMPONENTS
E
thernet
RJ-45 connector provides IP communication and PoE
Phoenix
Connector
Module-specific captive wire connectors (See below)