Administrator 

 

The Administrator tab has two functions: setting the module’s credentials and rebooting. 

 

To set a new username and password, fill out the 

User & Password

 form. 

Note: Only one set of credentials exist within the CE-series module.  Setting a new username and password will remove 

the previous set. 

To reboot the module, click the 

Reboot

 button on the upper right portion of the window. 

Summary of Contents for AMX CE Series

Page 1: ...INSTRUCTION MANUAL CE Series Universal Control Extenders INSTRUCTION MANUAL CE Series Universal Control Extenders CE IRS4 CE IO4 CE COM2 CE REL8...

Page 2: ...the HDMI cable with magnetic ring The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in th...

Page 3: ...more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from th...

Page 4: ...ED Behavior 6 LED PATTERNS 6 ID Button 6 Installation 7 Mounting Options Rack Trays and Mounting Brackets 7 VSTYLE DIN Rail Clip AMX CAC0001 7 AVB VSTYLE SURFACE MNT FG1010 722 7 AVB VSTYLE RMK FG1010...

Page 5: ...AMX CEB004 Control Extender 4 IO Common Features CE Series Common Features DIMENSIONS 1 x 4 1 16 x 4 3 32 2 5 cm x 10 3 cm x 10 4 cm 1 4 RU Width x 1 RU Height WEIGHT 1lb 454 g POWER REQUIREMENTS PoE...

Page 6: ...ll blink patterns for the Status and A L LEDs on the front panels of all CE modules LED PATTERNS The CE series features one tri color LED for status Color Frequency Status Green Solid Power no connect...

Page 7: ...e online at www amx com VSTYLE DIN Rail Clip AMX CAC0001 Small VSTYLE compatible modules can be mounted on a DIN rail with the VSTYLE DIN Rail Clip AVB VSTYLE SURFACE MNT FG1010 722 V Style Single Mod...

Page 8: ...down for ease of installation However the tray can be rack mounted in a rack either way Also note that the Fill Plate included in this illustration is included only in the AVB VSTYLE RMK FILL 1U FG101...

Page 9: ...re into the appropriate opening on the connector according to the wiring diagrams and connector types described in this section Note Do not tighten the screws excessively doing so may strip the thread...

Page 10: ...trol devices on their subnet Software such as CloudworX Desktop Manager can be used to discover the IP address that has been assigned via DHCP CloudworX Manager Additionally each CE Series module has...

Page 11: ...Instruction Manual 11 In this example the CE module sent the discovery broadcast from 192 168 160 174 when the ID button was tapped...

Page 12: ...s the module s web pages You are able to provide a new certificate later if desired Network The Network tab displays the current network settings and allow the user to set new network settings The MAC...

Page 13: ...each type of CE series box Different content is displayed for each CE REL8 8 Relay Module The status of each relay is displayed in the CE REL8 s Device page Clicking on the label or slider for a parti...

Page 14: ...e for that particular I O Each I O is individually configurable If the I 0 is set as an output there is only one further setting available Similar to the Relay the Output can be driven high or low by...

Page 15: ...the polling interval for the input state This prevents flooding of updates from unstable sources Digital Settings High Threshold in volts This sets the boundary for what is considered high for an inpu...

Page 16: ...rol Enable Receive determines if any messages received by that COM port should trigger an event for any clients that have subscribed If receiving a response is not desired turning Enable Receive off c...

Page 17: ...he COM port selected using the present RS 232 protocol settings for that port For demonstration purposes I wired COM 1 to COM 2 to show the Receive function To see the last message received by the CE...

Page 18: ...selected Next select the desired mode using the pulldown labelled IR Serial n Mode The modes are IR Serial and Data The IR mode expects to drive an IR emitter CC NIRC This emitter should be placed on...

Page 19: ...the captured buttons that will be available to this web page and the connected control system Only one IR file is active at a time IR Pulse allows you to select from a list of loaded captured IR butto...

Page 20: ...nsmits the IR code as 3 4 3 Mode 3 Use leading zeros or Hundred key No Enter key up to 3 digits 3 transmits the IR code as 0 3 34 transmits the IR code as 3 4 343 transmits the IR code as 100 100 100...

Page 21: ...ncy typically 41kHz is present in the output signal This should always on for use with an IR emitter Some wired IR connections may require removal of the IR carrier frequency Off Time For queued IR pu...

Page 22: ...r own certificate use the Browse button under Server Certificate to choose the file and Upload to install it The expected certificate format is an X 509 certificate PEM file To change the CE The HCont...

Page 23: ...ials and rebooting To set a new username and password fill out the User Password form Note Only one set of credentials exist within the CE series module Setting a new username and password will remove...

Page 24: ...Warranty and Return Policy and related documents can be viewed downloaded at www amx com 3000 RESEARCH DRIVE RICHARDSON TX 75082 AMX com 800 222 0193 469 624 8000 1 469 624 7400 fax 469 624 7153 Last...

Reviews: