background image

6

PC 45 Corn/Pellet Stove

6"

Fig. 7

10"

2"

1"

6"

W

it

h

 S

id

e

 S

h

ie

ld

s

FLOOR  PROTECTOR

6"

Fig. 8

18"

W

it

h

o

u

t S

id

e

 S

h

ie

ld

s

FLOOR  PROTECTOR

FL

O

O

PR

O

TE

C

TO

R

Fig. 6

Fig. 9: Refer to page 18 for
detailed draft settings and
adjustment procedures.

9"-13"

9"-13"

9" With Side Shields
13" Without Side Shields

Installation

Installing

Place the stove on a noncombustible floor protec-

tor   that  extends 6  inches to the  front,  6  inches to  the
sides and 1 inch to the rear of the stove. The minimum
floor protector material is 24 gauge sheet metal.

Place the stove away from combustible walls at least

as far as shown in figures  6,7 & 8. Please note the differ-
ence in side wall clearance with and without side shields.

Note  that  the clearances shown  are minimum  for

safety but do not leave much room for access when clean-
ing or servicing. Please take this into account when plac-
ing the stove.

Connect  the  power  cord  to  a  120  V.A.C.  60Hz

grounded receptacle. (A surge protector is recommened
to protect the circuit board).

Prior to installing the flue pipe, connect a draft meter

to the stove as shown  in fig. 9.   (The draft  meter must
have a minimum range of 0"- 0.5"). Turn stove to "TEST"
Mode and record the draft reading ______. After the flue
pipe is connected, check the draft reading again making
sure  all doors  and windows  in  the home are  closed. If
this reading is more than.05" higher than the unconnected
reading, check for  possible restrictions or the  need for
outside air. (See page 8).

Mobile  Home  Installation

When  installing  this  unit  in  a  mobile  home  several

requirements  must  be  followed:

1. The unit must be bolted to the floor. This can be done

with 1/4" lag screws through the 2 holes in the base plate.

2.  The  unit  must  also  be  connected  for  the  outside

air.  See  page  8.

3.  Floor  protection  and  clearances  must  be  followed

as  shown.

4.  Unit  must  be  grounded  to  the  metal  frame  of  the

mobile  home.

CAUTION: This appliance must be vented to the out-
side.

Due to high temperatures, the stove should be placed out of traffic

and away from furniture and draperies.

Children  and  adults  should  be  alerted  to  the  haz-

ards  of  high  surface  temperatures  and  should  stay  away
to  avoid  burn  to  skin  and/or  clothing.

Young  children  should  be  carefully  supervised  when

they  are  in    the same  room  as the  stove.

Clothing  and  other  flammable  materials  should  not

be  placed  on  or  near  this  unit.

Installation  and  repair  of  this  Harman  Stove  should

be  done  by  a  qualified  service  person.  The  appliance
should  be  inspected  before  use  and  at  least  annually by  a
qualified  service  person.  More  frequent  cleaning  will  be
required.  It  is  imperative  that  control  compartments,  burn-
ers,  and  circulating  air  passageways  of  the  stove  be  kept
clean.

Mobile  home  installation  should  be  done  in  accordance
with  the  Manufactured  Home and  Safety  Standard  (HUD),
CFR 3280, Part 24.

Summary of Contents for PC 45

Page 1: ...FETY FOLLOW INSTALLATIONDIRECTIONS CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS INYOUR AREA CONTACT YOUR LOCAL AUTHORITY SUCH AS MUNICIPAL BUILD...

Page 2: ...2 PC 45 Corn Pellet Stove...

Page 3: ...Sidewinder Burn Pot allows corn to be burned from three days up to a week without cleaning depending on the corn s moisture level and burn rate Automatic Ignition allows you to fill the hopper set yo...

Page 4: ...cover panels are removed from the stove to make it easier to get at the hold down bolts The rear cover panels are packed inside the hopper and should be installed on the stove as shown It is recommend...

Page 5: ...o clock position Does the door rope compress If not loosen the set screw turn the paw bolt one more turn into the door Repeat as required to achieve a tight door fit NOTE Remember to thoroughly clean...

Page 6: ...me are closed If this readingis more than 05 higher thanthe unconnected reading check for possible restrictions or the need for outside air See page 8 Mobile Home Installation When installing this uni...

Page 7: ...hen measured fromthe horizontalcenter line of the regu lator 1 I The clearance to service regulator vent outlet must be a minimum of 6 feet 1 J The clearance to a non mechanical air sup ply inlet to t...

Page 8: ...ide surface temperature to allow a clearance to combustibles of only 3 inches The sections of pipe lock together to form an air tight seal in most cases however in some cases a per fect seal is not ac...

Page 9: ...tural draft in the event of a power failure 2 Preferred method This method also provides excellent venting for normaloperation but requires the stove tobe installed farther from the wall The vertical...

Page 10: ...you may want to install a liner as in method 6 4 Installing into an existing fireplace chimney US only This method provides excellent venting for nor mal operation This method also provides natural dr...

Page 11: ...sure to use approved pellet vent pipe fittings Seal pipe joints with silicone in addition to the sealing system used by the manufacturer Pipesize shouldbe increased to 4 using this method 6 Installing...

Page 12: ...19 Fig 20 7 Installing through the ceiling vent Through the ceiling vent follow PL vent manufacturers recommendations when using wall and ceiling pass through DO NOT INSTALL A FLUE DAMPER IN THE EXHAU...

Page 13: ...with a 3 setting being the maximum setting 1 the lowest setting This set ting will vary depending on the quality of corn used When burning pellets the feed rate setting can be adjusted within the ful...

Page 14: ...s you to check the motors for operation NOTE The auger motor will not operate with the view door or ash door open NOTE The initial start upona newstove may require the corn to be purged into the burnp...

Page 15: ...l board setting The unit can only go to low burn and will remain there until it runs out of fuel or until more heat is needed and the feed rate in creases Feed rate adjustments and dial settings are t...

Page 16: ...n the Temperature Dial to the desired setting 4 Clean the burnpot and housing if necessary 5 Fill the burnpot with pellets so that the auger tube opening is covered and slopes away from the auger tube...

Page 17: ...ithin off position band except after normal shut down Blinks to indicate errors listed below Indicates power to distribution blower 6 Blinks Indicates that the control has calculated poor or incomplet...

Page 18: ...bustion Motor Speed Control Low draft only set point The small straight screwdriver slot is plastic therefore the unit can be adjusted while in operation Fig 29 Fig 30 A simple draft test should be pe...

Page 19: ...e to carry and dispose of ashes 3 Slide the ash pan back into the stove Cleaning If you have been burning corn the stove will need to be cleaned approximately once a month The amount of corn burned an...

Page 20: ...ing nut on the feeder cover and slide the cover off the threaded rod 3 Remove all fines with a vacuum Fig 37 Brush not supplied Can be found in hardware stores Fig 33 Latch closed with blower coverin...

Page 21: ...against the burnpot grate and housing 9 Install the front plate lock 10 The dirty auger extension burnpot grate and front plate just removed can now be cleaned for the next scheduled maintenance NOTE...

Page 22: ...s restricting fuel flow 4 Feed motor or draft motor has failed 5 Power failure or blown fuse SMOKE IS VISIBLE COMING OUT OF VENT 1 Air fuel ratio is too rich A Feed rate too high B Draft too low cause...

Page 23: ...Mounting Bolts 3 30 1311812513 Air Pump 3 20 02679 Air Pump Mounting Hardware BHSCS 8 32 x 1 4 3 30 3108320252 3 8 MPT x 1 4 Barb Brass Inlet Fitting 3 10 724203 Pusher Arm Mtng Bolts 4 3 30 22520050...

Page 24: ...all the hold down clips and tighten with bolts as shown on page 5 To install ash lip trim simply slide the trim over the ash lip and into the groove on the trim Gold Door The gold door fig 43 is assem...

Page 25: ...or should be installed in the loca tion where you want to control the temperature NOTE Distances of more than 25 feet from the unit or in another room are not recommended The room sensor is essentialf...

Page 26: ...26 PC 45 Corn Pellet Stove PC 45 Wiring Diagram...

Page 27: ...9301 5 Single Fan Blade 3 20 40985 Combustion Blower 3 21 08639 Distribution Blower 3 21 22647 Hopper Lid Latch 3 31 199110 3 16 Rubber Washer for Hopper Lid 3 31 90131101 Power Cord 3 20 29685 Fire B...

Page 28: ...Damage and or repairs including but not limited to remote controls filters fuses knobs glass ceramic brick panels ceramic fiber afterburners door packing tile ceramic log sets paint batteries or batt...