MKIV hydraulic unit 3
17
Assembly Foils/Connectors
Start plunger into injector and immediately
hold upright so plunger is down and
applicator tip is up.
As sealant runs down toward plunger an air
pocket will form near tip. Push plunger to
evacuate air. Begin injecting adhesive.
Hold plastic wedge in place with thumb
as you insert into foil. Line foil holes
with connector screw holes.
Tip: In cooler weather, keep sealed
adhesive in pocket to keep warm. Use
instructions below to fill injector less
than half way; you will only use a small
amount of adhesive. Refill if needed
but do not keep open sealant for long
periods. Use adhesive within three
(3) hours.
Use cap of adhesive to break seal. Remove
injector tip cap and plunger. Hold injector
at an angle with applicator tip facing down.
Squeeze adhesive into tube so lower half
of injector is full. Keep tip free
of sealant to let air inside.
Loading injector with adhesive
Adhesive in
lower half