background image

WALL SWITCH INSTALLATION

1. To install a wall switch, mount a standard 3”x 2” electrical box in wall near the fireplace.  Run thermostat wire (18 gauge 

wire) from the electrical box to the millivolt valve.  At the valve, the lead wires should be connected to the two outside 
terminals labeled “TH”.

See Figure 2

2. Mount the wall switch to the electrical box and install cover plate.

* If installing a remote control attach the leads from the receiver to the same terminals as the wall switch on the RMBE-
C.

LIGHTING INSTRUCTIONS

1.  Locate the pilot burner behind the ember burner.  Turn the RMBE control knob to the “PILOT” position.  Depress

inward on the control knob while lighting the pilot burner.  Allow the pilot to burn approximately 1 1/2 minutes before 
releasing the control knob.

• 

If pilot does not remain lit, repeat this step allowing a longer period prior to releasing the control knob.  The pilot
burner may require adjustment.  The pilot adjustment screw is located above the gas supply line for the pilot.  Remove 
the pilot adjustment cap to view the pilot adjustment screw.  The screw may be turned clockwise to reduce the pilot 
flame or counterclockwise to increase the pilot flame.  Assure that the pilot adjustment cap is replaced and tight prior 
to continuing installation.

2.   Turn the RMBE control knob counterclockwise to the “ON” position.
3.   Turn the wall switch to the “ON” position.  The burners should ignite within four seconds.  Turn the knob toward the 

“PILOT”

      position to reduce the main burner flame to a low setting and use a soapy solution to check for gas leaks from the 

RMBE valve to the burners.  Turn the RMBE control knob to the “OFF” position.  It will be necessary to depress the 
knob at the “PILOT” position to return to the “OFF” position.

BURNER PAN MEDIA

1. Fill the burner pan with

vermiculite

.

Vermiculite level

should be sloped evenly with the sides of the ember burner.

2.

Part B Embers

(rockwool) are placed over the sand to

simulate glowing embers.  For best results pinch off pieces 
of the Part B material the size of a dime and feather it out.
Place as much as desired over the area the gas comes
through.  Burner should be completely full and level.

See Figure 3

3.  Light the gas and observe flame for even distribution.  After 

checking the flame, turn off the fire.  (Turn the gas valve to

the

off

position to turn the fire off.)  Do not close the damper 

until all the flames have died.  Keep the glass doors fully
open during any operation of this appliance.

VERMICULITE

PART B
EMBERS

Figure 3

SWITCHING DEVICE

PILOT GENERATOR 

LEADS

FIGURE 2

f i r e - p a r t s . c o m

Summary of Contents for Summit Oak

Page 1: ...r 50 square inches The realistic yellow flame produces carbon monoxide and soot Under normal conditions these products are exhausted up the chimney If fumes or soot from the gas burning are evident in the room when the damper is fully open it indicates that the fireplace draft is defective Do not operate your gas log set until the fireplace draft is corrected IT IS THE HOMEOWNERS RESPONSIBILITY TO...

Page 2: ...n 7 After burning the logs become fragile and should not be handled Knocking or rubbing logs can cause concrete to crumble and is not covered under the warranty 8 Use a soft dry paintbrush for periodic dusting of the gas fire logs 9 Do not burn wood with this set PARTS LIST Remove all the parts from the shipping container Your set includes the following parts Description 36 Sets 42 48 Sets 1 Pedes...

Page 3: ...I CAUTIONS 1 This valve should be installed only by an experienced service technician trained in gas safety equipment 2 Turn off gas supply before installing valve 3 All piping must meet applicable local codes and ordinances and the national fuel gas code ANSI Z233 1 NFPA NO 54 4 All wiring must meet applicable electrical codes and ordinances 5 Check out the complete system after installing the va...

Page 4: ...e Assure that the pilot adjustment cap is replaced and tight prior to continuing installation 2 Turn the RMBE control knob counterclockwise to the ON position 3 Turn the wall switch to the ON position The burners should ignite within four seconds Turn the knob toward the PILOT position to reduce the main burner flame to a low setting and use a soapy solution to check for gas leaks from the RMBE va...

Page 5: ...4 The remaining logs are top logs They should be placed diagonally over the main logs See Figure 4 VOLCANIC CINDERS 1 The black volcanic cinders are used to cover the fireplace floor fittings and tubing around the burner system Although not functional the black cinders act as a picture frame to show off the glowing embers and yellow flame 2 The Part A Embers can spread over the volcanic cinders an...

Page 6: ...licable to this appliance is limited in duration to the same period of time as this written Warranty Some states do not allow limitations on how long an implied warranty lasts so the above limitations may not apply to you 3 HARGROVE MANUFACTURING CORPORATION WILL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL SPECIAL OR CONTINGENT DAMAGES YOU MIGHT SUFFER AS A RESULT OF A CLAIM UNDER THIS WRITTEN WARR...