background image

UNIT POSITION

1. Turn gas 

off

.

2. Remove old log lighter, ashes, and other 

material from the firebox.

3.  Center the 

ember burner 

on the fireplace floor 

with the burner pipe completely visible from the 
front.  For best results, the ember burner
should be directly under the flue opening with a 
minimum of 4” from the front edge of the ember 
burner to the fireplace opening.

4.  Place the 

pedestal grate assembly 

directly in 

front of the ember burner pipe 

5. The BB – BR brackets may be loosened to 

align the BB – 27 ignition tube to the back of 
the EB pan.

6. Connect the 

ember burner assembly 

to the 

pedestal grate assembly

 by tightening the 

AC-SU (Item 21 in Parts List) to the 3 – way 
brass fitting (Item 16 in Parts List) on the 
ember burner assembly.

     See Figure 1

This gas pilot safety valve provides 100% shut-off of both pilot and main burner gas supply in the event of 
pilot flame failure.  This valve is equipped with a manual gas control knob to provide for pilot lighting.  It also 
has a control knob that controls flame height.

If the pilot flame goes out during normal operation, or if there is insufficient pilot flame to provide proper 
thermocouple output, the safety valve will close, stopping the flow of all gas.  This valve is designed for use
on all domestic heating gases up to ½” PSI.

CAUTIONS

1. This valve should be installed only by an experienced service technician trained in gas safety equipment.
2. Turn off gas supply before installing valve.
3. All piping must meet applicable local codes and ordinances and the national fuel gas code (ANSI Z233.1/NFPA 

NO. 54)

4. All wiring must meet applicable electrical codes and ordinances.
5. Check out the complete system after installing the valve.
6. Prior to installation, verify conformance with burner manufacturer’s installation instructions.

Make sure all piping is free of foreign matter.

GAS CONNECTION

1. The gas supply line should be 1/2” inside diameter (ID) up to 30 feet.
2. Assure that the inlet gas supply is turned off, prior to installing this appliance.
3. Remove any items from the fireplace and clean the interior of the fireplace.
4. Connect the Standard Elbow to the 1/2" inlet supply pipe.
5. Use the AC – 18 (Item 6) to connect the gas supply to the inlet of the RMBE pilot control.  When bending the

aluminum tubing use proper bending procedures to avoid kinking the tube.  *Do not use flexible gas connections with 
this appliance.  Flexible connectors may cause undue noise issues.

6. Check all connections for leaks using a soapy water solution.
7. Damper must remain fully open during operation.

Figure 1

WARNING:

Valves may not shut off if 

flow is not in direction of arrow on valve 
body.

 WARNING:

Warranty is void if the

 RSBMV-C is installed behind the burner
 pan in the fireplace.

BB – BR

Ignition tube

f i r e - p a r t s . c o m

Summary of Contents for Summit Oak

Page 1: ...r 50 square inches The realistic yellow flame produces carbon monoxide and soot Under normal conditions these products are exhausted up the chimney If fumes or soot from the gas burning are evident in the room when the damper is fully open it indicates that the fireplace draft is defective Do not operate your gas log set until the fireplace draft is corrected IT IS THE HOMEOWNERS RESPONSIBILITY TO...

Page 2: ...n 7 After burning the logs become fragile and should not be handled Knocking or rubbing logs can cause concrete to crumble and is not covered under the warranty 8 Use a soft dry paintbrush for periodic dusting of the gas fire logs 9 Do not burn wood with this set PARTS LIST Remove all the parts from the shipping container Your set includes the following parts Description 36 Sets 42 48 Sets 1 Pedes...

Page 3: ...I CAUTIONS 1 This valve should be installed only by an experienced service technician trained in gas safety equipment 2 Turn off gas supply before installing valve 3 All piping must meet applicable local codes and ordinances and the national fuel gas code ANSI Z233 1 NFPA NO 54 4 All wiring must meet applicable electrical codes and ordinances 5 Check out the complete system after installing the va...

Page 4: ...e Assure that the pilot adjustment cap is replaced and tight prior to continuing installation 2 Turn the RMBE control knob counterclockwise to the ON position 3 Turn the wall switch to the ON position The burners should ignite within four seconds Turn the knob toward the PILOT position to reduce the main burner flame to a low setting and use a soapy solution to check for gas leaks from the RMBE va...

Page 5: ...4 The remaining logs are top logs They should be placed diagonally over the main logs See Figure 4 VOLCANIC CINDERS 1 The black volcanic cinders are used to cover the fireplace floor fittings and tubing around the burner system Although not functional the black cinders act as a picture frame to show off the glowing embers and yellow flame 2 The Part A Embers can spread over the volcanic cinders an...

Page 6: ...licable to this appliance is limited in duration to the same period of time as this written Warranty Some states do not allow limitations on how long an implied warranty lasts so the above limitations may not apply to you 3 HARGROVE MANUFACTURING CORPORATION WILL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL SPECIAL OR CONTINGENT DAMAGES YOU MIGHT SUFFER AS A RESULT OF A CLAIM UNDER THIS WRITTEN WARR...

Reviews: