UNIT POSITION
1. Turn gas
off
.
2. Remove old log lighter, ashes, and other
material from the firebox.
3. Center the
ember burner
on the fireplace floor
with the burner pipe completely visible from the
front. For best results, the ember burner
should be directly under the flue opening with a
minimum of 4” from the front edge of the ember
burner to the fireplace opening.
4. Place the
pedestal grate assembly
directly in
front of the ember burner pipe
5. The BB – BR brackets may be loosened to
align the BB – 27 ignition tube to the back of
the EB pan.
6. Connect the
ember burner assembly
to the
pedestal grate assembly
by tightening the
AC-SU (Item 21 in Parts List) to the 3 – way
brass fitting (Item 16 in Parts List) on the
ember burner assembly.
See Figure 1
This gas pilot safety valve provides 100% shut-off of both pilot and main burner gas supply in the event of
pilot flame failure. This valve is equipped with a manual gas control knob to provide for pilot lighting. It also
has a control knob that controls flame height.
If the pilot flame goes out during normal operation, or if there is insufficient pilot flame to provide proper
thermocouple output, the safety valve will close, stopping the flow of all gas. This valve is designed for use
on all domestic heating gases up to ½” PSI.
CAUTIONS
1. This valve should be installed only by an experienced service technician trained in gas safety equipment.
2. Turn off gas supply before installing valve.
3. All piping must meet applicable local codes and ordinances and the national fuel gas code (ANSI Z233.1/NFPA
NO. 54)
4. All wiring must meet applicable electrical codes and ordinances.
5. Check out the complete system after installing the valve.
6. Prior to installation, verify conformance with burner manufacturer’s installation instructions.
Make sure all piping is free of foreign matter.
GAS CONNECTION
1. The gas supply line should be 1/2” inside diameter (ID) up to 30 feet.
2. Assure that the inlet gas supply is turned off, prior to installing this appliance.
3. Remove any items from the fireplace and clean the interior of the fireplace.
4. Connect the Standard Elbow to the 1/2" inlet supply pipe.
5. Use the AC – 18 (Item 6) to connect the gas supply to the inlet of the RMBE pilot control. When bending the
aluminum tubing use proper bending procedures to avoid kinking the tube. *Do not use flexible gas connections with
this appliance. Flexible connectors may cause undue noise issues.
6. Check all connections for leaks using a soapy water solution.
7. Damper must remain fully open during operation.
Figure 1
WARNING:
Valves may not shut off if
flow is not in direction of arrow on valve
body.
WARNING:
Warranty is void if the
RSBMV-C is installed behind the burner
pan in the fireplace.
BB – BR
Ignition tube
f i r e - p a r t s . c o m