background image

OPERATION 

 

FOR YOUR SAFETY READ BEFORE LIGHTING 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

LIGHTING INSTRUCTIONS 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

A.  This appliance has a pilot which is lighted by a 
spark igniter system.  When lighting the pilot, follow 
these instructions exactly. 
B.  BEFORE LIGHTING smell all around the appliance 
area for gas.  Be sure to smell next to the floor 
because some gas is heavier than air and will settle on 
the floor. 
WHAT TO DO IF YOU SMELL GAS: 

• 

Do not try to light any appliance. 

• 

Do not touch any electric switch; do not use 
any phone in your building. 

• 

Immediately call your gas supplier from a 
neighbor’s phone.  Follow the gas supplier’s 
instructions.  

• 

If you cannot reach your gas supplier, call the 
fire department. 

WARNING:  If you don not follow these instructions 
exactly, a fire or explosion may result causing 
property damage, personal injury or loss of life. 
 
C.  Use only your hand to push in or turn the gas 
control knob.  Never use tools.  If the knob will not 
push in or turn by hand, do not try to repair it, call 
a qualified service technician.  Force or attempt 
repair may result in a fire or explosion and may 
void your warranty. 
D.  Do not use the appliance if any part has been 
under water.  Immediately call a qualified service 
technician to inspect the appliance and to replace 
any part of the control system and any gas control 
which has been under water. 

1.  STOP!  Read the safety information above on this 
label. 
2.  Turn off all electrical power in the firebox before 
installing. 
3.  Turn the control knob clockwise         as far as it will 
go to reach the “OFF” position. 
4.  Wait five (5) minutes to clear out any gas.  Then 
smell for gas, including near the floor.  If you smell 
gas, STOP!  Follow “B” in the safety information above 
on this label.  If you do not smell gas, go to the next 
step. 
5.  Turn the Control Knob counterclockwise         to the 
“PILOT” position. 
 
 
 
 
 
 
 
 
6.  Push in control knob and hold it in. 
7.  Light the pilot (mounted in the front of the back 
burner) by pushing the spark ignitor button several 
times.  This will cause a spark at the pilot which will 
ignite the gas.  If the spark does not work, light the 
pilot with a match. 

* When lighting the pilot it may take several 
seconds for gas to reach the pilot. 

8.  Continue to hold the control knob in all the way for 
about 30 seconds after the pilot is lit. 
9.  Release the knob and it will pop back out.  The pilot 
should remain lit.  If it goes out, repeat steps 3 thru 9. 

*  If knob does not pop up when released, stop 
and immediately call your service technician or 
gas supplier 
*  If the pilot does not stay lit after several tries, 
turn the gas control knob “OFF” and call your 
service technician or gas supplier. 

 

7.  Turn gas flame height control knob 
counterclockwise            to “ON”.  Turn flame 
height control knob counterclockwise to select the 
desired comfort level. 
 
IMPORTANT:  The gas control knob has an 
interlock device.  After shutting off all gas flow, the 
pilot burner cannot be relit until the thermocouple 
has cooled, allowing the electromagnet to be 
released (approx. 60 sec.).  The gas control knob is 
designed to be operated by hand.  DO NOT use any 
tools during this operation.  Damaged knobs may 
result in serious injury. 
 
NOTE:  A periodic visual check of the pilot flames 
(Figure 11) and main burner flames should be 
made.  The pilot flame should always be present 
when the appliance is in operation.  See illustration 
below. 
 
Fig 11 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
WARNING:  TAMPERING WITH THE ODS PILOT 
WILL VOID THE MANUFACTURER’S WARRANTY. 

 

 

 

WARNING: At no time should the “LIGHTING INSTRUCTION” tags be detached from the burner 
system.  Removing the tags will void the manufacturer’s warranty. 

NATURAL GAS 

ODS PILOT 

LIQUID PROPANE 

ODS PILOT 

 

Control 

Knob 

Spark 

Ignitor 

13 

Summary of Contents for Highland Glow

Page 1: ...mage Refer to this manual For assistance or for additional information consult a qualified installer service agency or gas supplier This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases Solid fuels shall not be burned in a fireplace where an unvented room heater is installed WARNING If information in this manual...

Page 2: ...n 5 Gas Line Hook Up 6 Gas Pressure Check 7 Wiring Schematic Millivolt Units Only 7 Log Placement Timberland Glow 22 Model 8 Log Placement Timberland Glow 26 Model 9 Log Placement Highland Glow 22 and 26 Models 10 Ember Placement 11 Volcanic Cinder Placement 12 OPERATION 13 16 Lighting Instructions Manual Burner 13 Lighting Instructions Variable Burner 14 Lighting Instructions Millivolt Burner 15 ...

Page 3: ...used by a ceiling fan near the fireplace a hot furnace or an open door WARNING DO NOT ALLOW FANS TO BLOW DIRECTLY INTO THE FIREPLACE AVOID ANY DRAFTS THAT ALTER BURNER FLAME PATTERNS 4 Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies Young children should be carefully supervised when they are in the same room with the appliance 5 Childre...

Page 4: ...e room can support STEP THREE ADD THE BTU Hr OF ALL THE FUEL BURNING APPLIANCES IN THE SPACE VENT FREE HEATER_________________BTU Hr GAS APPLIANCE 1 _________________BTU Hr GAS APPLIANCE 2 _________________BTU Hr Example VENT FREE HEATER 26 000 BTU Hr GAS APPLIANCE 1 35 000 BTU Hr TOTAL 61 000 BTU Hr NOTE DO NOT INCLUDE DIRECT VENT GAS APPLIANCES DIRECT VENT IS SEALED COMBUSTION AND DRAWS COMBUSTI...

Page 5: ...5 ins WC 11 ins WC 4 ins WC 10 ins WC When operating the main burner use the control knob to raise and lower the min and max heat output Turn the control knob counterclockwise for max heat and clockwise for min heat Input ratings are shown in BTU per hour and are for elevations up to 2 000 feet For elevations above 2 000 feet input ratings should be reduced 4 for each 1 000 feet above sea level Re...

Page 6: ...g fire In most cases they should also be adequate to prevent any discoloration or warping due to heat However each Gas Log installation will present unique circumstances creating many variables beyond the control of the Gas Log Manufacturer including paint or finish composition previous heat exposure quality of construction air flow patterns etc Because of these variables we cannot guarantee that ...

Page 7: ...orm with state and local codes or in absence of local codes to the National Fuel Gas Code ANSI Z223 1 IMPORTANT Before installing in a solid fuel burning fireplace the chimney flue and firebox must be cleaned of soot creosote ashes and loose paint by a qualified chimney cleaner 1 Turn the gas supply to OFF 2 Turn OFF all electrical power to blower if applicable before installing servicing or remov...

Page 8: ...e 3 Include a manual shutoff valve in the gas supply line so the appliance may be disconnected for servicing 4 Center the burner system from side to side in the firebox In a vented firebox if the damper is used the burner assembly should be located directly under the damper 5 Use the 3 8 aluminum connector provided in the accessory kit to connect the gas supply line to the regulator on the burner ...

Page 9: ... technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water 7 CAUTION Label all wire prior to disconnection when servicing controls Wiring errors can cause improper an dangerous operation Verify proper operation after service WALL SWITCH INSTALLATION 1 To install a wall switch mount a 3 X 2 electrical box in the wall near the fi...

Page 10: ... of the left Back Log The branch from the top log faces forward and will rest on the left Front Log Fig 2 3 1 2 3 4 5 Back Logs Front Logs Top Log Back Burner Plate Front Burner Plate Fig 1 Fig 2 Fig 3 Fig 4 Step 4 Assure that all of the logs have at least a 1 clearance around the burner ports of the Back Burner Fig 3 Step 5 Once the set is completely set up observe the operation of the set The ba...

Page 11: ...4 Install the right Top Log by placing the holes in the bottom of the right Top Log over the pins in the right Front Log The small branch on the right Top Log faces back and will rest on the extension on the back right log Fig 2 3 1 2 3 4 5 6 Back Logs Front Logs Top Logs Back Burner Plate Front Burner Plate Fig 1 Fig 2 Step 4 Assure that all of the logs have at least a 1 clearance around the burn...

Page 12: ... back and front log The branch should be facing forward Fig 1 2 Step 5 Install the right Top Log 5 by placing the flat side of the log on the notches on the top side of the back and front log The branch should be facing forward Fig 1 2 Step 6 Install the middle Top Log 6 with the charred end resting in the notch on the top of the Front Left Log and the other end resting on the front flat area of t...

Page 13: ...ERIAL INTO THE BURNER PORTS WARNING DO NOT PUT ANY ADDITIONAL EMBER MATERIAL ON THE BURNER SYSTEM USE ONLY WHAT WAS PROVIDED WITH THE SET PLACING ADDITIONAL EMBER MATERIAL ON THE SET MAY CAUSE IMPROPER COMBUSTION AND WILL VOID THE MANUFACTURER S WARRANTY 4 You may place some ember material on the tube that connects the front and back burner Do not press the ember material into the ports as it may ...

Page 14: ...INDER ON THE BURNERS OR AROUND THE PILOT 2 You may use the Volcanic Cinder to cover up the Lighting Tags that are attached to the set DO NOT REMOVE THE LIGHTING TAGS FROM THE BURNER SYSTEM THIS WILL VOID THE MANUFACTURER S WARRANTY 12 3 You may use the Volcanic Cinder to cover the horizontal portion of the front of the grate DO NOT POUR VOLCANIC CINDER ON THE BURNER OR AROUND THE PILOT VOLCANIC CI...

Page 15: ... smell gas go to the next step 5 Turn the Control Knob counterclockwise to the PILOT position 6 Push in control knob and hold it in 7 Light the pilot mounted in the front of the back burner by pushing the spark ignitor button several times This will cause a spark at the pilot which will ignite the gas If the spark does not work light the pilot with a match When lighting the pilot it may take sever...

Page 16: ...erclockwise to the IGN ignition position 6 Once again the IGN position push the knob in as far as it will go This action releases gas flow to the pilot 7 While holding in the Pilot Ignitor Knob turn it counterclockwise to activate the spark ignitor on the pilot This will cause a spark at the pilot which will ignite the pilot gas If the spark does not work light the pilot with a match When lighting...

Page 17: ...ove on this label If you do not smell gas go to the next step 5 Depress the control knob and turn counterclockwise to the PILOT position LIGHTING INSTRUCTIONS WARNING At no time should the LIGHTING INSTRUCTION tags be detached from the burner system Removing the tags will void the manufacturer s warranty Fig 10 GAS CONTROL Flame Height Control Knob Control Knob NOTE A periodic visual check of the ...

Page 18: ...terns Do not allow fans to blow directly into the fireplace Ceiling fans may create drafts that alter burner flame patterns Sooting and improper burning will occur Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequent cleaning may be required due to excessive lint from c...

Page 19: ... REGULATOR 1G NG 1 REG 4 REG 4 REGULATOR 1G LP 1 REG 10 REG 10 N SPARK IGNITOR 1G 1 SIT PIEZO SIT PIEZO O 1 8 FIP X 3 8 COMPRESSION 2 70 6 2 70 6 2 P 3 8 STREET ELBOW 1G 1 SE 6 SE 6 Q 3 8 ML X 3 8 FL 1 48 6 48 6 R OXYGEN DEPLETION SYSTEM NG 1 OP 8203 ODS NG OP 8203 ODS NG OXYGEN DEPLETION SYSTEM LP 1 OP 8403 ODS LP OP 8403 ODS LP S BACK BURNER CONNECTOR 1E 1 TCB MAX TCB MAX T FRONT BURNER CONNECTO...

Page 20: ... VALVE 1 SIT MIL NG VAVLE SIT MIL NG VALVE CONVERSION FOR NATURAL GAS 1 SITMILCNG SITMILCNG CONVERSION FOR LIQUID PROPANE GAS 1 SITMILCLP SITMILCLP G SPARK IGNITOR 1 SIT PIEZO SIT PIEZO H 3 8 ML X 3 8 FL 2 48 6 48 6 I MILLIVOLT OXYGEN DEPLETION SENSOR NG 1 OP 8205 MODS NG OP 8205 MODS NG MILLIVOLT OXYGEN DEPLETION SENSOR LP 1 OP 8405 MODS LP OP 8405 MODS LP J BACK BURNER CONNECTOR 1 TCB MIL TCB MI...

Page 21: ...alve not fully open 4 Thermocouple connection loose at valve 5 Pilot flame not touching thermocouple which allows thermocouple to cool causing pilot flame to go out This problem could be caused by one or both of the following A Log gas pressure B Dirty or partially clogged ODS pilot 6 Thermocouple damage 7 Control valve damage 1 Not enough fresh air available for ODS pilot to operate 2 Low gas pre...

Page 22: ...h paint fumes cleaning agents pet hair or other particles are cycling thru the fireplace when it is operating 2 Gas leak 1 Logs are not positioned properly and are obstructing the flame 2 Main burner has accumulated dust or other small particles REMEDY 1 Turn on gas supply or open manual shutoff valve 2 Turn control knob to PILOT position then depress knob 3 Press in control knob while in PILOT po...

Page 23: ...ty applicable to this appliance is limited in duration to the same period of time as this written Warranty Some states do not allow limitations on how long an implied warranty lasts so the above limitations may not apply to you 3 HARGROVE MANUFACTURING CORPORATION WILL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL SPECIAL OR CONTINGENT DAMAGES YOU MIGHT SUFFER AS A RESULT OF A CLAIM UNDER THIS WRITTE...