background image

6

INSTALLATION INSTRUCTIONS

FOR

HARGROVE RADIANT GLOW

Page 2

BURNER PAN MEDIA

1.

Fill the burner pan with 

silica sand

.  Sand level should 

be sloped evenly with the sides of the ember burner.
Place 2/3 of the 

rockwool/embers

 on top of the sand.

The burner should be completely full and level.  The
rockwool simulates glowing embers.  For best results, 
feather the edges of the rockwool out.  Place as much 
as desired over the area the gas comes through.

2. Sprinkle a small portion of the

vermiculite/embers

over the rockwool.

3.   Light the gas and observe flame for even distribution.

(See Figure IV)

LOG PLACEMENT

1.  The two widest logs are for a

front log

 application.

They should be placed as illustrated in Figure V.

2.   The lightweight ceramic fiber log is the 

back log

. Flip 

the back log over to find the positioning slots that allow 
it to fasten into place on the grate.  (The bottom side 
with the slots is a flat untextured side that has notches 
that lay over the pedestals of the grate).  Place the slots 
over the vertical portion of the PGRG brackets.  The
notches should extend over the pedestal of the grate.
(See Figure VI)

3. The remaining logs are

top logs

.  These logs are

bridged between the front logs and the back log.

VOLCANIC CINDERS

1. The black

volcanic cinders

are used to cover the

fireplace floor, fittings and tubing around the burner
system.  Although not functional, the black cinders act 
as a picture frame to show off the glowing embers and 
yellow flame.

\

Figure IV

Vermiculite

Rockwool

Sand

Figure V

FOR YOUR SAFETY

Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect
the appliance and to replace any part of the system or gas
control that has been under water.

Keep this appliance clear and free of combustible
materials, gasoline, and other flammable vapors or liquids.

Figure VI

f i r e - p a r t s . c o m

Summary of Contents for AKXRG5/8CPCNG

Page 1: ...other flammable vapors and liquids in the vicinity of this or any other appliance FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS 1 Do not try to light any appliance 2 Do not touch any electrical switch 3 Do not use any phone in your building 4 Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions 5 If you cannot reach your gas supplier call the fire departm...

Page 2: ...r soot exist in the room while the gas is burning and the damper is fully opened it indicates that the fireplace draft is defective Do not operate your gas log set until the fireplace draft is corrected Consult your fireplace specialist 7 A fireplace screen must be in place when the appliance is operating unless other provisions for an air supply are provided The screen shall have openings for the...

Page 3: ... TABLE II FOR MASONRY BUILT FIREPLACES FREE OPENING AREA OF CHIMNEY DAMPER FOR VENTING COMBUSTION PRODUCTS FROM DECORATIVE APPLIANCES FOR INSTALLATION IN SOLID FUEL BURNING FIREPLACES Appliance Input Rate kBTU hr 20 30 40 50 60 70 80 90 100 110 120 6 8 10 15 20 30 Chimney Height ft 17 6 25 7 33 8 41 7 49 2 56 6 64 0 71 4 78 8 86 2 93 5 16 5 23 7 31 2 38 7 45 5 52 4 59 7 66 9 74 1 81 3 88 6 15 1 21...

Page 4: ...Regulator 18 Super Wool 21 SETS PG 16 EB 14 HBF 18 CPE PO HS CPC 250 PGRG2124 RSTPB 18NG EM 1 RGAC 19 SD 1 VC 1 NOT SHOWN DS AC 18 PPH 2 39 28 8 6 27 50 6 8 REG 4 0 NOT SHOWN 24 SETS PG 20 EB 18 HBF 24 CPE PO HS CPC 250 PGRG2124 RSTPB 18NG EM 1 RGAC 17 SD 1 VC 1 NOT SHOWN DS AC 18 PPH 2 30 28 8 6 23 50 6 8 REG 4 0 NOT SHOWN 30 SETS PG 25 EB 22 HBF 24 CPE PO HS CPC 250 PGRG30 RSTPB 18NG EM 1 RGAC 1...

Page 5: ...ve the grate and proceed with the gas connection See Figure II GAS CONNECTIONS 1 The gas supply line should be 1 2 inch inside diameter up to 30 feet and 3 4 inch for longer distances 2 Use the aluminum connector to connect the gas supply to the manifold regulator When bending the aluminum tubing use proper bending procedures to avoid kinking the tube 3 Use the RGAC Burner Connector to connect the...

Page 6: ...fasten into place on the grate The bottom side with the slots is a flat untextured side that has notches that lay over the pedestals of the grate Place the slots over the vertical portion of the PGRG brackets The notches should extend over the pedestal of the grate See Figure VI 3 The remaining logs are top logs These logs are bridged between the front logs and the back log VOLCANIC CINDERS 1 The ...

Page 7: ...licable to this appliance is limited in duration to the same period of time as this written Warranty Some states do not allow limitations on how long an implied warranty lasts so the above limitations may not apply to you 3 HARGROVE MANUFACTURING CORPORATION WILL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL SPECIAL OR CONTINGENT DAMAGES YOU MIGHT SUFFER AS A RESULT OF A CLAIM UNDER THIS WRITTEN WARR...

Reviews: