background image

4

RADIANT GLOW 

Parts list

ITEM DESCRIPTION

1.  Pedestal Grate
2.  Ember Burner
3.  HVF-Burner
4.  CPE Pilot Control
4a CPE Heat Shield
5.  Burner Brackets 
6.  Thermocouple
7. Embers
8.  Burner Connector
9.  Sand
10.  Volcanic Cinder
11.Fire Logs
12.Damper Stop
13.  Aluminum 
       Connector
14. HVF-Orifice
15. EB Orifice
16. 3/8 FL x 1/2 Elbow

   (2 Required)

17.  Regulator
18.  Super Wool 

21” SETS

PG-16

EB-14

HBF-18

CPE-PO

HS-CPC-250

PGRG2124

RSTPB-18NG

EM-1

RGAC-19

SD-1
VC-1

NOT SHOWN

DS

AC-18

PPH-2#39

28-8-6 #27

50-6-8

REG-4.0

NOT SHOWN

24” SETS

PG-20

EB-18

HBF-24

CPE-PO

HS-CPC-250

PGRG2124

RSTPB-18NG

EM-1

RGAC-17

SD-1
VC-1

NOT SHOWN

DS

AC-18

PPH-2#30

28-8-6 #23

50-6-8

REG-4.0

NOT SHOWN

30” SETS

PG-25
EB-22

HBF-24

CPE-PO

HS-CPC-250

PGRG30

RSTPB-18NG

EM-1

RGAC-16

SD-1
VC-1

NOT SHOWN

DS

AC-18

PPH-2#30

28-8-6 #22

50-6-8

REG-4.0

NOT SHOWN

1

3

2

4a

6

7

5

8

9

11

12

13

15

14

4

16

17

f i r e - p a r t s . c o m

Summary of Contents for AKXRG5/8CPCNG

Page 1: ...other flammable vapors and liquids in the vicinity of this or any other appliance FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS 1 Do not try to light any appliance 2 Do not touch any electrical switch 3 Do not use any phone in your building 4 Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions 5 If you cannot reach your gas supplier call the fire departm...

Page 2: ...r soot exist in the room while the gas is burning and the damper is fully opened it indicates that the fireplace draft is defective Do not operate your gas log set until the fireplace draft is corrected Consult your fireplace specialist 7 A fireplace screen must be in place when the appliance is operating unless other provisions for an air supply are provided The screen shall have openings for the...

Page 3: ... TABLE II FOR MASONRY BUILT FIREPLACES FREE OPENING AREA OF CHIMNEY DAMPER FOR VENTING COMBUSTION PRODUCTS FROM DECORATIVE APPLIANCES FOR INSTALLATION IN SOLID FUEL BURNING FIREPLACES Appliance Input Rate kBTU hr 20 30 40 50 60 70 80 90 100 110 120 6 8 10 15 20 30 Chimney Height ft 17 6 25 7 33 8 41 7 49 2 56 6 64 0 71 4 78 8 86 2 93 5 16 5 23 7 31 2 38 7 45 5 52 4 59 7 66 9 74 1 81 3 88 6 15 1 21...

Page 4: ...Regulator 18 Super Wool 21 SETS PG 16 EB 14 HBF 18 CPE PO HS CPC 250 PGRG2124 RSTPB 18NG EM 1 RGAC 19 SD 1 VC 1 NOT SHOWN DS AC 18 PPH 2 39 28 8 6 27 50 6 8 REG 4 0 NOT SHOWN 24 SETS PG 20 EB 18 HBF 24 CPE PO HS CPC 250 PGRG2124 RSTPB 18NG EM 1 RGAC 17 SD 1 VC 1 NOT SHOWN DS AC 18 PPH 2 30 28 8 6 23 50 6 8 REG 4 0 NOT SHOWN 30 SETS PG 25 EB 22 HBF 24 CPE PO HS CPC 250 PGRG30 RSTPB 18NG EM 1 RGAC 1...

Page 5: ...ve the grate and proceed with the gas connection See Figure II GAS CONNECTIONS 1 The gas supply line should be 1 2 inch inside diameter up to 30 feet and 3 4 inch for longer distances 2 Use the aluminum connector to connect the gas supply to the manifold regulator When bending the aluminum tubing use proper bending procedures to avoid kinking the tube 3 Use the RGAC Burner Connector to connect the...

Page 6: ...fasten into place on the grate The bottom side with the slots is a flat untextured side that has notches that lay over the pedestals of the grate Place the slots over the vertical portion of the PGRG brackets The notches should extend over the pedestal of the grate See Figure VI 3 The remaining logs are top logs These logs are bridged between the front logs and the back log VOLCANIC CINDERS 1 The ...

Page 7: ...licable to this appliance is limited in duration to the same period of time as this written Warranty Some states do not allow limitations on how long an implied warranty lasts so the above limitations may not apply to you 3 HARGROVE MANUFACTURING CORPORATION WILL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL SPECIAL OR CONTINGENT DAMAGES YOU MIGHT SUFFER AS A RESULT OF A CLAIM UNDER THIS WRITTEN WARR...