background image

5

INSTALLATION INSTRUCTIONS

FOR

HARGROVE RADIANT GLOW

DAMPER STOP

(OPTIONAL)

Attach the damper stop clamp to the fireplace damper 
blade.  Position the clamp to prevent full closure of the 
fireplace damper blade. 
(See Figure I)

See Table II for Minimum Opening Requirements.

EMBER BURNER POSITIONING

1.  Turn your gas supply 

off

.

2.  Remove the old log lighter, ashes, and any other 

loose material from the firebox.

3. Center the 

Ember Burner 

on the fireplace floor 

with the burner pipe completely visible from the 
front of the fireplace.  For best results, the ember 
burner should be directly under the flue opening 
with a minimum of 4” from the front edge of the 

ember burner to the fireplace opening.

4.  Place the 

grate

over the ember burner so the 

front legs of grate are just in front of the ember 
burner pipe.  Once the final positioning is 
established, mark the burner and grate position 
on the floor of the fireplace for reference points.
Remove the grate and proceed with the gas 
connection.  (See Figure II)

GAS CONNECTIONS

1.  The gas supply line should be 1/2 inch inside diameter

up to 30 feet and 3/4 inch for longer distances.

2.  Use the 

aluminum connector

 to connect the gas 

supply to the manifold regulator.  When bending the 
aluminum tubing, use proper bending procedures to 
avoid kinking the tube.

3.  Use the 

RGAC Burner Connector 

to connect the 

Ember Burner 

to the 

Grate and HVF-Burner

Assembly

.

4.  Turn the gas supply on and check all gas connections 

from the inlet gas supply to the Ember Burner for leaks 
using soapy water.

5.  The damper must be open during any operation.  Place 

a lighted match next to the burner pipe.  Do not hold the 
match in your hand while lighting the gas.  Turn the gas 
valve on slowly until the gas ignites.  Check the flame for 
even distribution and pressure.  Turn the gas valve to 
the off position.  Do not close the damper until all the 
flames have extinguished.  Keep the glass doors open 
during any operation of the unit.  (See Figure III) 

*  CAUTION  *

THE DAMPER MUST BE OPEN WHEN 

OPERATING THE GAS LOGS!

Figure I

DAMPER STOP

Figure II

Figure III

f i r e - p a r t s . c o m

Summary of Contents for AKXRG5/8CPCNG

Page 1: ...other flammable vapors and liquids in the vicinity of this or any other appliance FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS 1 Do not try to light any appliance 2 Do not touch any electrical switch 3 Do not use any phone in your building 4 Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions 5 If you cannot reach your gas supplier call the fire departm...

Page 2: ...r soot exist in the room while the gas is burning and the damper is fully opened it indicates that the fireplace draft is defective Do not operate your gas log set until the fireplace draft is corrected Consult your fireplace specialist 7 A fireplace screen must be in place when the appliance is operating unless other provisions for an air supply are provided The screen shall have openings for the...

Page 3: ... TABLE II FOR MASONRY BUILT FIREPLACES FREE OPENING AREA OF CHIMNEY DAMPER FOR VENTING COMBUSTION PRODUCTS FROM DECORATIVE APPLIANCES FOR INSTALLATION IN SOLID FUEL BURNING FIREPLACES Appliance Input Rate kBTU hr 20 30 40 50 60 70 80 90 100 110 120 6 8 10 15 20 30 Chimney Height ft 17 6 25 7 33 8 41 7 49 2 56 6 64 0 71 4 78 8 86 2 93 5 16 5 23 7 31 2 38 7 45 5 52 4 59 7 66 9 74 1 81 3 88 6 15 1 21...

Page 4: ...Regulator 18 Super Wool 21 SETS PG 16 EB 14 HBF 18 CPE PO HS CPC 250 PGRG2124 RSTPB 18NG EM 1 RGAC 19 SD 1 VC 1 NOT SHOWN DS AC 18 PPH 2 39 28 8 6 27 50 6 8 REG 4 0 NOT SHOWN 24 SETS PG 20 EB 18 HBF 24 CPE PO HS CPC 250 PGRG2124 RSTPB 18NG EM 1 RGAC 17 SD 1 VC 1 NOT SHOWN DS AC 18 PPH 2 30 28 8 6 23 50 6 8 REG 4 0 NOT SHOWN 30 SETS PG 25 EB 22 HBF 24 CPE PO HS CPC 250 PGRG30 RSTPB 18NG EM 1 RGAC 1...

Page 5: ...ve the grate and proceed with the gas connection See Figure II GAS CONNECTIONS 1 The gas supply line should be 1 2 inch inside diameter up to 30 feet and 3 4 inch for longer distances 2 Use the aluminum connector to connect the gas supply to the manifold regulator When bending the aluminum tubing use proper bending procedures to avoid kinking the tube 3 Use the RGAC Burner Connector to connect the...

Page 6: ...fasten into place on the grate The bottom side with the slots is a flat untextured side that has notches that lay over the pedestals of the grate Place the slots over the vertical portion of the PGRG brackets The notches should extend over the pedestal of the grate See Figure VI 3 The remaining logs are top logs These logs are bridged between the front logs and the back log VOLCANIC CINDERS 1 The ...

Page 7: ...licable to this appliance is limited in duration to the same period of time as this written Warranty Some states do not allow limitations on how long an implied warranty lasts so the above limitations may not apply to you 3 HARGROVE MANUFACTURING CORPORATION WILL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL SPECIAL OR CONTINGENT DAMAGES YOU MIGHT SUFFER AS A RESULT OF A CLAIM UNDER THIS WRITTEN WARR...

Reviews: