7 - Fault Finding
156
Liquid System
FAULT
PROBABLE CAUSE
CONTROL / REMEDY
No spray from boom when turned on.
SmartValve/Pressure valve positions are wrong.
Set correct valve positions for spraying.
Suction/pressure filters clogged.
Clean suction and pressure filters.
No suction from tank.
See if suction fitting in main tank sump is free of
sedimentation. Clean if needed.
Lack of pressure.
Incorrect assembly.
Boost valve has a defect (it is located at the bottom
of the pressure filter). The valve seat is worn or
missing.
Air in system.
Fill suction hose with water for initial priming.
Too much agitation.
Close the agitation valve.
Pump valves are clogged or worn.
Check for obstructions and wear.
Clogged filters.
Clean all filters.
Defective pressure gauge.
Check for dirt at inlet of pressure gauge.
Pressure dropping.
Filters are clogging.
Clean all filters. Fill with cleaner water. If using
powders, make sure agitation is on.
Nozzles worn.
Check nozzle output. Replace nozzles, if the
deviation in output exceeds 10%.
Sucking air towards end of tank load.
Lower pump speed (rpm).
Pressure increasing.
Pressure filters beginning to clog.
Clean all filters.
Formation of foam.
Air sucked into the liquid system.
Check tightness / gaskets / O-rings of all fittings on
suction side.
Excessive liquid agitation.
Lower pump speed (rpm).
Check safety valve is tight.
Ensure returns inside the tank are present.
Use a foam-damping additive.
Operating unit is not functioning, or it is having a
malfunction.
Blown fuse(s).
Check mechanical function of micro switches. Use
cleaning/lubricating agent if the switch does not
operate freely.
Check motor current, max. 450-500 mA. If over,
change the motor.
Wrong polarity.
Brown to positive (+). Blue to negative (-).
Valves not closing properly.
Check valve seals for obstructions.
Check position of the micro switch plate. Loosen the
screws holding the plate a 1/2 turn.
No power.
Wrong polarity. Check that brown is positive (+), blue
is negative (-).
Check print plate for dry solders or loose
connections.
Check fuse holder is tight around fuse.
Summary of Contents for NAVIGATOR EAGLE 3000
Page 4: ...1 EU Declaration 4 ...
Page 42: ...2 General Safety Instructions 42 ...
Page 68: ...3 Description 68 ...
Page 86: ...4 Sprayer Setup 86 ...
Page 117: ...6 Maintenance 117 Lubrication Plan Boom Wings ...
Page 178: ...HARDI INTERNATIONAL A S Herthadalvej 10 DK 4840 Nørre Alslev DENMARK ...