22
HARDI
®
FALCON BOOM OPERATOR‘S MANUAL
1. Dilute the remaining spray liquid in the tank with at least 10 times
the amount of water and spray the liquid out into the field you have
just sprayed.
2. Select and use the appropriate protective clothing. Select detergent
suitable for cleaning and suitable deactivating agents if necessary.
3. Flush and clean the sprayer and tractor externally. Use detergent if
necessary.
4. Remove all the filters and clean them - be careful not to damage
their mesh. Re-fit the filters when the sprayer is completely clean.
5. Clean the pressure relief valve and attached hose of any residue.
6. With the pump running, flush the inside of the tank (remember the
tank roof). Flush and operate all components and any equipment
that has been in contact with the chemical. Before opening the
distribution valves and spraying the liquid out, decide whether this
should be done in the field again or on the soakway.
7. After spraying the liquid out, stop the pump and fill at least 20% of
the tank with clean water. Note that some chemicals require the
tank to be completely filled. Add appropriate detergent and/or
deactivating agent, e.g. Washing Soda or Triple Ammonia.
NOTE!
If a cleaning procedure is given on the chemical label,
follow it closely.
8. Start the pump and operate all controls, enabling the liquid to come
in contact with all the components. Leave the distribution valves
until last. Some detergents and deactivating agents work best if left
in the tank for a short period. Check the label.
9. Drain the tank and if the pump is able to - let the pump run dry.
Flush the inside of the tank, again letting pump run dry (if possible).
10. If the chemicals used have a tendency to block nozzles and filters,
remove and clean them now.
11. Re-fit all the filters and nozzles and store the sprayer. If from
previous experiences, it is noted that the solvents and the chemi-
cals are particualarly aggressive, store the sprayer with the tank lid
open.
8.2 Lubrication
Lubrication of the boom daily will ensure maximum performance and life.
This lubrication includes the H-Frame and center frame as well as the
boom hinges.
Summary of Contents for FALCON Boom HY
Page 1: ...FALCON Boom 67000003 4 00 Operator s Manual ...
Page 2: ......
Page 7: ...5 HARDI FALCON BOOM OPERATOR S MANUAL HARDI FALCON Boom 50 shown ...
Page 32: ...30 HARDI FALCON BOOM OPERATOR S MANUAL 10 3 Hydraulic Schematics A HY Schematics Fig 16 ...
Page 33: ...31 HARDI FALCON BOOM OPERATOR S MANUAL B Tilt Schematics Fig 17 LEFT TILT RIGHT TILT VENTS ...
Page 36: ...34 HARDI FALCON BOOM OPERATOR S MANUAL 12 0 NOTES ...
Page 37: ...35 HARDI FALCON BOOM OPERATOR S MANUAL NOTES ...
Page 38: ...36 HARDI FALCON BOOM OPERATOR S MANUAL NOTES ...
Page 39: ......