4 - Sprayer Setup
92
Electrical Connections
Power Supply
Power requirement is 12 V DC. Always note the polarity!
For proper function of the electric equipment for the sprayer, the tractor
must have the following sizes of electric wires and fuses installed.
The delivered power connectors follow the standard of most modern tractors. If you have a tractor with another power
connector, it is necessary to disassemble the connector and fit it to the actual sprayer connector. Contact your HARDI dealer.
The delivered connectors may vary on the sprayer, depending on its equipment and scope of supply.
Spray box connector, 1-pin plug
The unit requires:
Wire 2.5 mm
2
. Fuse 10 amps.
Hydraulic control unit requires:
Wire 4.0 mm
2
. Fuse 16 amps.
Tractor must follow ISO 4165.
JobCom connector, 3-pin plug
The unit requires:
Wire 6.0 mm
2
. Fuse 25 amps.
Tractor must follow DIN 9680.
Traffic light connector, 7-pin plug
The unit requires:
Wire 6x 1.5 mm
2
+ 1x 2.5 mm
2
.
The cable is custom made and must not
be changed to another type.
Tractor must follow ISO 1724.
ISOBUS connector, 9-pin plug
The unit requires:
Wire 2x 10 mm
2
+ 2x 2.5 mm
2
+ 2x (2x 0.5 mm
2
)
The cable is custom made and must not be
changed to another type.
Tractor must follow ISO 11783-2.
Cabin connector for grip control and Setbox:
HARDI item no. 26031500
Power and data connector, 13-pin plug
Used for controller model HC 6500.
If needed, buy one of these tractor kits to
complete the setup:
HARDI item no. 26049400 (incl. NORAC system)
HARDI item no. 26013900 (excl. NORAC system)
Tractor must follow ISO 11446.
Summary of Contents for COMMANDER DELTA FORCE
Page 4: ...1 EU Declaration 4 ...
Page 44: ...2 General Safety Instructions 44 ...
Page 78: ...3 Description 78 ...
Page 104: ...4 Sprayer Setup 104 ...
Page 136: ...5 Operation 136 ...
Page 165: ...6 Maintenance 165 5 Insert the locking piece in the upper part to secure it on the spray boom ...
Page 186: ...6 Maintenance 186 ...
Page 194: ...7 Fault Finding 194 ...
Page 212: ...8 Technical Specifications 212 ...
Page 216: ...Index 216 ...
Page 218: ...HARDI INTERNATIONAL A S Herthadalvej 10 DK 4840 Nørre Alslev DENMARK ...