6 - Maintenance
146
Tightening Hydraulic Hoses
When tightening hydraulic hoses as a part of periodic service or due to replacement of spare parts, it is important to apply
the correct torque. This will prevent accidents and prolong the lifetime of the parts connected with the hoses.
If not otherwise stated in this book, please tighten hydraulic hoses using the following torques:
€
DANGER! A hydraulic hose or joint leaking or coming apart with the oil under pressure can cause severe injuries to
persons standing nearby! The oil can be very hot, around 80 °C, and the oil streaming out can penetrate human skin.
Risk of burns on the skin, internal injuries and facial injuries.
±
WARNING! Applying too little torque will result in these risks:
±
WARNING! Applying too much torque will result in these risks:
±
WARNING! When assembling a hydraulic joint, this is often being twisted around in different directions to make it fit
between other components on the sprayer. Remember to finish off by applying the correct torque.
÷
NOTE! The sealing system for hoses and fittings is ORFS type (O-Ring Face Seal). This ensures a high level of sealing
and good vibration resistance. The fittings use the O-ring compression mechanism to seal.
Hose size
Thread size
Spanner size
Recommended torque
1/4 “
9/16 “
19 mm
28 Nm
3/8 “
11/16 “
22 mm
44 Nm
1/2 “
13/16 “
24 mm
62 Nm
3/4 “
13/16 “
36 mm
130 Nm
•
hydraulic joints will leak due to the high oil pressure.
•
hydraulic joints will rattle and thus fail under fatigue.
•
hydraulic joints are being worn quickly and thus will not fulfil their design purpose.
•
accidents caused by sudden loss of oil pressure due to hydraulic parts coming apart.
•
damaging or stripping the threads and deforming the hydraulic joints.
•
fittings will be broken.
•
hydraulic joints will leaks.
•
accidents caused by assembled parts coming apart due to bolts breaking at a later time.
Summary of Contents for COMMANDER DELTA FORCE
Page 4: ...1 EU Declaration 4 ...
Page 44: ...2 General Safety Instructions 44 ...
Page 78: ...3 Description 78 ...
Page 104: ...4 Sprayer Setup 104 ...
Page 136: ...5 Operation 136 ...
Page 165: ...6 Maintenance 165 5 Insert the locking piece in the upper part to secure it on the spray boom ...
Page 186: ...6 Maintenance 186 ...
Page 194: ...7 Fault Finding 194 ...
Page 212: ...8 Technical Specifications 212 ...
Page 216: ...Index 216 ...
Page 218: ...HARDI INTERNATIONAL A S Herthadalvej 10 DK 4840 Nørre Alslev DENMARK ...