F1
F2
F3
E1
E2
F1
Compressor fuse
F2
Condenser fuse
F3
Evaporator fuse
E1
Clutch air conditioning relay
E2
Condenser relay
C1
Condenser motor
C
Air conditioning speed control switch
TH
Thermostat
M
Evaporator motor
R
Resistor
P
Pressure freon gauge
E
6
6-
1
1
-
2
2
A
AIIR
R C
CO
ON
ND
DIIT
TIIO
ON
NIIN
NG
G W
WIIR
RIIN
NG
G D
DIIA
AG
GR
RA
AM
M
The compressor does not work
The condenser do not work
The evaporator do not work
- Check that the thermostat works correctly
- Check the relay
(E1) and fuse (F1) of the compressor clutch
- Check the relay
(E2) and fuse (F2) of the condenser controller
- Check that the ‘’binary’’ pressure works correctly.
- Check the gas pressure and that the refrigeration circuit is air tight
- Clean the condenser.
- Check fuse
(n°3)
- The cabin fan does not work