Page 9
For technical questions, please call 1-888-380-0318.
Item 63617
SAFETY
MAINTENANCE
BASIC WELDING
WELDING TIPS
SETUP
6.
10-12 Pound Wire Spool Installation:
Remove the Wingnut and Spacer. If
replacing a Spool, remove the old Spool
and all remaining wire from the liners.
7. Place the Spool Adapter over the Spool Spindle
and against the Spool Brake Pad as illustrated.
8. Place the new Wire Spool over the Adapter and
line up pin on Adapter with hole in Spool.
To prevent wire feed problems, set the
Spool so that it will unwind clockwise.
9. Replace the Spacer over the Spool Spindle
and secure Spool in place with the Wingnut.
Notice:
If Wire Spool can spin freely, Wingnut
is too loose. This will cause the welding
wire to unravel and unspool which can
cause tangling and feeding problems.
10. Screw the Spool Knob into the Spool Adapter.
11.
DCEN Direct Current Electrode Negative
Wire Setup for Flux-Cored (gasless) welding:
Remove the two Wingnuts securing the cables.
Connect the Black Ground Cable to the positive (
+
)
Terminal using the Wingnut.
Connect the Red Cable to the negative (
–
)
Terminal using the other Wingnut.
Make sure the Cable connectors
sit flush in the grooves.
Welder
Wall
Spool
Brake Pad
10-12 lb
Spool
Adapter
10-12 lb Spool Loading
Wingnut
10-12 lb
Wire Spool
Spacer
Spool Spindle
Spool Knob
Wire
must
unwind
in this
direction
DCEN
Flux-Cored (Gasless) Polarity Setup
Summary of Contents for Vulcan Migmax 215
Page 1: ......