Page 15
For technical questions, please call 1-888-866-5797.
Item 91062
SaFEty
OpEra
tiOn
MaintEnancE
SEtup
replacing the Belt
Before beginning, turn the Depth
Adjustment Knob to the “0” setting.
1. Remove the Screws (3) that attach the
Belt Cover (2) to the Planer, then remove
the Belt Cover. See
Figure J
.
Belt
cover
(2)
Figure J:
2. Remove the worn or broken Belt (9) from
the Large and Small Pulleys (14 and 4).
Use a screwdriver or similar tool to stretch the
Belt slightly to remove it. See
Figure K
.
Large
pulley
(14)
Old
Belt
Small
pulley
(4)
Figure K:
3. Clean the Pulleys and the area around them.
4. Place the new Belt around the Large Pulley,
making sure that the Belt is centered
on the Pulley. See
Figure L
.
new
Belt
Figure L:
5. Use a screwdriver or similar tool to stretch the Belt
all the way over the Small Pulley. See
Figure M
.
Figure M:
6.
iMpOrtant:
Center the belt on both pulleys so that
all the ridges on the inside of the Belt are aligned
with all the grooves on both Pulleys. See
Figure n
.
Figure n:
7. Replace the Belt Cover. See
Figure O
.
Figure O: