• THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE 

INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION 
OF THE PRODUCT AND THE HAZARDS INVOLVED.

• 

All electrical connections must be in agreement with local codes and ordinances, the National 

Electric Code (NEC) and ANSI/NFPA 70-1999. Contact your municipal building department to learn 
about your local codes, permits and/or inspections. 

Risk of 

fire - most dwellings built before 1985 

have supply wire rated for 140 °F. Consult a qualified electrician before installation. 

• To avoid personal injury, the use of gloves may be necessary while handling fixture parts with sharp 

edges.

• 

DO NOT suspend any fixture by the house wires. A fixture must always be mounted directly to a 

mounting plate that is first attached to the outlet box. All fixtures must be mounted to an outlet box 
that is supported by the building structure. Wire connectors will not support the weight of a fixture. 
Suspending a fixture by the house wires and wire connectors will result in the fixture falling, with 
the possibility of personal injury and the danger of electrical shock or fire.

• 

To reduce the risk of fire, electrical shock or personal injury, wire connectors provided with this 

light 

fixture are designed to accept only one 12-gauge house wire and two lead wires from the light 
fixture. If your house wire is larger than 12-gauge or there is more than one house wire to connect 
to the corresponding fixture lead wires, consult an electrician for the proper size wire connectors to 
use.

 

To reduce the risk of damage to the fixture, DO NOT use power tools to assemble any part of the 

fixture.

• Failure to caulk fixture mounting surface with silicone weather sealant may result in water damage 

in outlet box, which may cause electrical malfunction or electrical shock.

• To avoid water damage to fixture or possible electrical malfunction, install fixture at least 4 ft. above 

the ground/floor.

SAFETY INFORMATION

WARNING

• TURN OFF ELECTRICITY at main fuse box (or circuit breaker box) before beginning installation by 

removing the fuse (or switching the circuit breaker off).

• If you are not sure the lighting system has a grounding means, DO NOT attempt to install these 

fixtures. Contact a qualified, licensed electrician for information regarding the proper grounding 
methods as required by the local electrical code in your area.

• All fixtures must be mounted to an outlet box that is supported by the building structure.
• DO NOT use bulbs having a wattage greater than the maximum value stated on the fixture. The use 

of bulbs with higher wattage than specified will increase temperatures and risk of fire.

• If a dimmer control switch is used with these fixtures, obtain professional advice to determine the 

correct type to use as well as the electrical rating required.

CAUTION

 

DO NOT connect the bare or green insulation fixture ground wire to the black (HOT) 

current-carrying wire or the white (NEUTRAL) house wire. Connection of the bare or green fixture 
ground wire to the black or white house wires may cause metal parts of the fixture to carry 
electrical currents. Under this condition, anyone coming in contact with the fixture will receive 
electrical shock, which could cause serious injury or death.

 

DO NOT damage or cut the wire insulation (covering) during installation of fixture. DO NOT permit 

wires to contact any surface having a sharp edge. To do so may damage or cut the wire insulation, 
which could cause serious injury or death from electrical shock.

DANGER

Summary of Contents for WL131MBK

Page 1: ...artment at 1 888 251 1003 8 a m 8 p m EST Monday Sunday You could also contact us at partsplus lowes com ITEM 2062005 2602006 E87731 For Wet Location HARBOR BREEZE and logo design are trademarks or re...

Page 2: ...TENTS Package Contents 2 Hardware Contents 3 Safety Information 3 Preparation 5 Assembly Instructions 5 Care and Maintenance 10 Troubleshooting 10 Warranty 10 TABLE OF CONTENTS A Fixture 1 PART DESCRI...

Page 3: ...connected to a supply circuit that is protected by a Ground Fault Circuit Interrupter GFCI to reduce the risk of personal injury electrical shock or death DO NOT connect this fixture to an electrical...

Page 4: ...to caulk fixture mounting surface with silicone weather sealant may result in water damage in outlet box which may cause electrical malfunction or electrical shock To avoid water damage to fixture or...

Page 5: ...hardware contents list If any part is missing or damaged do not attempt to install operate or assemble the product Estimated Assembly Time 30 minutes Tools Required for Assembly not included Flathead...

Page 6: ...ted to an outlet box that is supported by the building structure and can support the weight of the fixture Plastic outlet boxes are not recommended 6 ASSEMBLY INSTRUCTIONS 4 Hardware Used Fixture Scre...

Page 7: ...e nuts DD fit flush against fixture A when mounted Once fixture screws CC are adjusted use pliers not included to tighten nuts EE securely against mounting plate AA Set fixture A aside 5 5 Outlet Box...

Page 8: ...re connectors BB provided with this light fixture are designed to accept only one 12 gauge house wire and two lead wires from the light fixture If your house wire is larger than 12 gauge or there is m...

Page 9: ...LED equivalent WARNING When replacing bulb please allow bulb and fixture A to cool down before touching them 9 Bulb not included A 8 Align holes in fixture A with fixture screws CC on mounting plate...

Page 10: ...ion and limitation may not apply This warranty gives you specific rights and you may also have other rights which may vary from state to state WARRANTY TROUBLESHOOTING WARNING Before beginning work sh...

Page 11: ...iente al al 1 888 251 1003 de lunes a domingo de 8 a m a 8 p m hora est ndar del Este Usted tambi n podr a comunicarse con nosotros en partsplus lowes com MODELO WL131MBK WL131WW APROBADO PARA UTILIZA...

Page 12: ...12 Aditamentos 13 Informaci n de seguridad 13 Preparaci n 15 Instrucciones de ensamblaje 15 Cuidado y mantenimiento 20 Soluci n de problemas 20 Garant a 20 CONTENIDO DEL PAQUETE NDICE PIEZA DESCRIPCI...

Page 13: ...tegido con un Interruptor de circuito de falla de puesta a tierra GFCI por sus siglas en ingl s para disminuir el riesgo de lesiones personales descargas el ctricas o la muerte NO conecte esta l mpara...

Page 14: ...lador de silicona para todo clima se pueden producir da os causados por el agua en la caja de salida lo que a su vez puede causar un mal funcionamiento el ctrico o descargas el ctricas Para evitar da...

Page 15: ...pinzas cortacables gafas de seguridad escalera de tijera cinta aislante sellador de silicona para todo clima y herramienta para aplicar el sellador de silicona Herramientas tiles no se incluyen luz de...

Page 16: ...debe montar en una caja de salida que est sostenida de la estructura del edificio y que sostendr el peso de una l mpara No se recomienda el uso de cajas de salida de pl stico AA 4 Tornillos y arandel...

Page 17: ...ara CC NOTA los tornillos de la l mpara CC deben pasar por los orificios en la parte superior de la l mpara A lo suficiente como para que las tuercas decorativas DD queden al ras de la l mpara A cuand...

Page 18: ...uctor NEGRO de la caja de salida con el conector de cables existente o el conector de cables BB NOTA enrosque los conectores de cables AA en direcci n de las manecillas del reloj ADVERTENCIA nunca con...

Page 19: ...bombilla CFL LED equivalente ADVERTENCIA cuando reemplace la bombilla deje que sta y la l mpara A se enfr en antes de tocarlas 8 A DD CC CC AA 9 A Aditamentos utilizados Tornillo de la l mpara x 2 CC...

Page 20: ...do GARANT A Impreso en EE UU INSTRUCCIONES DE ENSAMBLAJE 11 Luego de completar la instalaci n calafatee la superficie de montaje de la l mpara A con sellador de silicona para todo clima ADVERTENCIA si...

Reviews: