19
WARNING
: Before beginning work, shut off the power supply to avoid electrical shock.
PROBLEM
POSSIBLE CAUSE
CORRECTIVE ACTION
Fan does not move.
1. Reverse switch not engaged.
2. Power is off or fuse is blown.
3. Faulty wire connection.
4. Learning code process between fan
and remote control transmitter may
not have been successful and
learning code was not activated.
1. Push switch firmly either left or
right.
2. Turn power on or check fuse.
3. Turn power off. Loosen canopy
and check all connections.
4. Turn off power and repeat
instructions in Step 2 on page
17.
Noisy operation.
1. Blades are loose.
2. Cracked blade.
3. Full range dimmer switch.
4. Fan is new.
1. Tighten all blade screws.
2. Replace blade.
3. Replace with an approved
speed control device.
4. Allow fan a “break in” period of
a few days, especially when
running the fan at Medium and
High speeds.
Excessive wobbling.
1. Blades are loose.
2. Unbalanced blades.
3. Fan not securely mounted.
4. Fan too close to vaulted ceiling.
5. Set screw(s) on motor housing yoke
is (are) not tightened properly.
1. Tighten all blade screws.
2. Switch one blade with a blade
from the opposite side.
3. Turn power off. Carefully loosen
canopy and verify that mounting
bracket is secure.
4. Use a longer downrod or move
fan to another location.
5. Tighten yoke set screw(s)
securely.
NOTE:
A small amount of "wobble" is normal and should not be considered a defect.
TROUBLESHOOTING
Fan operates but
light fails.
1. Wires in canopy not wired
properly.
2. Wall switch to fan is off.
1. Check wires in canopy and, if
necessary, re-wire according to
instructions on pages 13 and 14.
2. Make sure that wall switch to
fan is on.