11. Pre-Heating
◈
Overview of Pre-Heating
◈
Start and finish Pre-Heating
◈
Conditions for start of Pre-Heating
▶
Pre-Heating is a function for freeze protection in winter target value for pre-heat
can be set in Pre-heat SV" on Control screen during pre-heating process, ON/OF
control is conducted according to pre-set "Pre-heating SV" (Initial value: 15C).
target value for pre-heat can be set in Pre-heat SV" on Control screen.
■
12. Control sensor conversion
▶
You can connect 4 temperature sensors together (Mold, MEDI, RETURN, ENTER).
▶
"MEDI sensor" and "MOLD sensor" is for control.
▶
"RETURN sensor" and "ENTER sensor" is for monitoring you can check
temperature in "CONTROL" --> " TEMP.DISPLAY".
▶
Select whether to use "MEDI sensor" and "MOLD sensor" by using "MOLD" key.
▶
It is set to "MEDI sensor" by default. If pressing MOLD key, "MOLD" LED flashes
and mode changes to "MOLD sensor"
▶
You can start and finish Pre-Heating by "PRE-H" key or communication
during pre-heating operation, press "RUN/RESET" key to stop pre-heating and
immediately start operation. However, if there is reservation, pre-heating
continues till reserved time.
▶
Pre-Heating cannot start during operation or SUCTION.
▶
Pre-heating can be operated during Forced COOLING or Manual Control mode.
however, be cautious as the priority for output is on Forced COOLING and Manual
Control.