Pr
ogr
ammable T
emper
atur
e & Humidity Contr
oller
16
Digit
al Mold Contr
oller
◈
Phase detection terminal on power board
◈
Display contact input and communication terminal
③ Connect to R phase for controlling 3 phase.
③ Connect to S phase for controlling 3 phase.
③ Connect to T phase for controlling 3 phase.
▶
In case of inappropriate connections for R,S, and T, it
generates alarm and cannot start control operation.
▶
To clear reverse phase alarm, connect R, S, and T in
proper way or turn on the power after selecting ‘Single
phase’ on ‘Heating output’ screen.
R
S
T
1
2
3
Phase check
1
2
DI R/S
1
2
3
4
5
TX+
TX-
RX+
RX-
SG
Comm
RS422/485
Terminal input for RUN/RESET
▶
It operates same as RUN/RESEY Key.
▶
When terminal input is ON, it starts control.
When it is off, control stops.
Communication terminal
▶
RS422/485 communication terminal
Summary of Contents for MT100