14
Digit
al Mold Contr
oller
◈
Input terminal on main board
◆
Input terminal for monitoring system
DI terminal
14
13
6
5
4
3
2
1
Heat
PP_D
PP-R
OPT
PRS
WT_H
WT_L
12
11
10
9
8
7
② Terminal to monitor overheating
▶
Using by connecting temperature limit switch.
▶
When contact is input in this part, it stops control
and alert the user.
⑪ Terminal to monitor pressure fault
▶
Using by connecting the pressure limit switch.
▶
When contact is input in this part, it continues
control but alerts the user.
⑥ Terminal to monitor directs operation of pump and
overload
▶
When contact is input in this part, it stops control
and alerts the user.
⑥ Terminal to monitor reverse operation of pump and
overload
▶
Using by connecting pressure limit switch When
contact is input in this part, it stops control and
alerts the user.
⑤ Terminal to monitor high water-level limit
▶
Using by connecting float limit switch.
▶
When contact is input in this part, it stops water
filling by turning off water filling relay.
⑤ Terminal to monitor low water-level limit
▶
Using by connecting float limit switch.
▶
When contact is input in this part, it starts water
filling by turning on water filling relay.