Pr
ogr
ammable T
emper
atur
e & Humidity Contr
oller
34
Digit
al Mold Contr
oller
■
04. Input settings
◈
Set temperature input sensor
◈
Set temperature
◈
Decimal point of temperature
◈
Temperature unit
◈
Temperature BIAS
▶
You can connect 4 temperature input sensors (Mold, MEDI, Return, and ENTER).
▶
You can select one of types (Pt100Ω, K(CA), and J) for each sensor.
▶
Set in "SENSOR"
▶
You can set Max and Min temperature limit.
▶
All temperature settings and control will be conducted within the configured
range.
▶
Set in " DISPLAY " --> "TEMP.RANGE".
▶
Select whether to use decimal point.
▶
Cannot use decimal point if temp unit is Fahrenheit.
▶
Set in " DISPLAY " --> "Decimal" .
▶
You can select either C or F.
▶
When the temp unit changes, "TEMP.RANGE" and all related parameters are
initialized.
▶
Set in "DISPLAY" --> "TEMP BIAS".
▶
You can calibrate the temperature of each sensor.
▶
Set in "Operation screen" --> "TEMP BIAS".
Summary of Contents for MT100
Page 1: ......