HANYOUNG NUX MT100 User Manual Download Page 1

Summary of Contents for MT100

Page 1: ......

Page 2: ...s guide will be provided in this form and can be edited or changed without prior notice This guide includes an implied guarantee or suitability for a certain purpose and does not offer any guarantee f...

Page 3: ...een Layout and Structure 08 Option Screen Layout and Structure 09 Error Info Screen Layout and Structure 10 Language Setting Screen Layout and Structure 11 Parameters Reference Table 01 Front Panel La...

Page 4: ...duct Verification Check packing contents Damaged product 01 Check the contents Once you receive the product please check for external damage Please check whether the product specification is the same...

Page 5: ...mponents MT100 Display Unit MT100 User Manual MT100 Main Unit Connection cable Communication cable 2 pin terminal 7 Pieces 3 pin terminal 1 piece 6 pin terminal 2 or 3 pieces 8 pin terminal 2 pieces 3...

Page 6: ...ion of the product For the safety and protection of the system that uses this product please read and follow the manual with care We are not liable for any damage and safety problems due to disregards...

Page 7: ...power of all the units and products before connecting the cables to each other Please do not touch the product with wet hands It can cause electric shock Never use any gas pipe lighting rods or elect...

Page 8: ...el Number Description MT100 Mold Temperature Controller Communication 0 No communication 1 RS485 422 Pressure check 0 No pressure check 1 Pressure check by input of contact 2 Pressure check by 4 20 mA...

Page 9: ...reen Parameters Handling and Operating Specifications Installation Unit mm Unit mm 01 External Dimensions and Panel Cutout External Dimensions Panel Cutout 155 0 130 0 8 8 114 0 23 3 25 3 140 0 23 3 2...

Page 10: ...ed off and connect cables to the units Cause of Noise Relay and Contact Motor commutator Solenoid Coil Solenoid Valve Phase angle SCR Power Line Remote Communication equipment Inductance Load Welding...

Page 11: ...ect action of pump 13 14 Heat over Input Terminal for checking overheating CT Sensor terminal 1 2 CT1 CT sensor terminal for checking current on R 3 4 CT2 CT sensor terminal for checking current on S...

Page 12: ...R 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 CT SENSOR RELAYOUTPUT Control DI INPUT Heat over Pump dir over pump rev over Option Pressure over W Fill hi W Fill low Test pin Display connector P...

Page 13: ...nal 1 2 R S RUN RESET Contact Input Terminal COMM TERMINAL Communication Terminal 1 2 3 4 RS422 485 Communication Terminal 5 Communication Signal Ground Terminal Main CN Terminal for connection with M...

Page 14: ...water ENTER valve Cooling valve Heat exchanger Overheating detector Heater MEDI temperature sensor Float switch Pump Enter cooling water Return cooling water Enter medium Return medium Mold Mold temp...

Page 15: ...nnect pressure sensor It displays pressure by retrieving 4 20 mA of current Terminal to connect temperature sensor of medium water When Mold Key is OFF reads and controls temperature via the temperatu...

Page 16: ...ut alerts the user Terminal to monitor directs operation of pump and overload When contact is input in this part it stops control and alerts the user Terminal to monitor reverse operation of pump and...

Page 17: ...o reverse operation Relay for water lling When DI of WT_L is on relay is on and starts water lling When it is o the relay o and so does the water lling Relay for direct operation of pump Relay is on w...

Page 18: ...of inappropriate connections for R S and T it generates alarm and cannot start control operation To clear reverse phase alarm connect R S and T in proper way or turn on the power after selecting Singl...

Page 19: ...MEDIUM RETURN WATER ENTER WATER 3 SENSOR 4 DISPLAY ENTER WATERR ENTER WATERR EPRES RANGE TEMP RANGE ACCURACY TEMP UNIT MOLD BIAS MEDIUM BIAS R WATER BIAS E WATER BIAS PRE_HEAT SV Contrast adjustment s...

Page 20: ...rature Current time Current day Current date Set value 28 0 PV SV MV 28 0 AUTO Operating 00 00 PRS Output mode Auto and Manual Operation mode Operating and Tuning 28 0 PV SV 28 0 10 01 SAT 12 00 00 00...

Page 21: ...Auto and Manual Operation mode Operating and Tuning 28 0 PV SV MV 28 0 Scheduledtime 12 34 00 00 PRS Operation starts 12 hours and 34 minutes later PV SV MV S Shows s stop nt time ating 0 00 ode Tunin...

Page 22: ...L Ph Ih Dh Th Pc Ic Dc Tc MODE Ph 15 0 Ih 240 Second Dh 60 Second Th 2 Second SET MENU Heating setting P Heating setting I Heating setting D Control heating setting Pc 15 0 Ic 240 Second Dc 60 Second...

Page 23: ...OUT Single phase 3 phase PRES LO ALM 00 00 CUR HI ALM 040 0 A TEMP HI ALM 300 0 TEMP LO ALM 000 0 A TEMP LO ALM 000 0 ALARM COOL OUT HEAT OUT TEMP HI ALM ALARM TEMP LO ALM PRES HI ALM PRES LO ALM ALA...

Page 24: ...Setting Screen Layout and Structure MOLD Pt100 K TYPE J TYPE MOLD SETTING MEDIUM Pt100 K TYPE J TYPE RETURN WATER Pt100 K TYPE J TYPE ENTER WATER Pt100 K TYPE J TYPE RETURNWATER SETTING MEDIUM SETTIN...

Page 25: ...0 A S 000 0 A T 000 0 A 20 mA pressure 10 00 4 mA pressure 00 00 TEMP HI 300 0 TEMP LO 000 0 Mold BIAS 000 0 PRE_HEAT SV 015 0 DISPLAY TEMP DISPLAY CUR DISPLAY PRES RANGE DISPLAY TEMP RANGE ACCURACY...

Page 26: ...ME 00 01 02 03 Time setting 31 DEC 05 Sat 23 59 DELAY TIME Hour 02 Min 03 MEDI FILL TM 0000 Second WEEK RSV Sun Mon Tue Wed Thu Fri Sat TIME RSV MODE CURRENT TIME WEEK RSV TIME WEEK TIME DELAY TIME ME...

Page 27: ...er to use SUCTION OPTION SUCTION COOLING REMOTE OPTION LOCK PASSWORD ID SUCTION ON OFF COOLING ON OFF REMOTE ON OFF Decide whether to use LOCK LOCK ON OFF Password setting 0000 CONTROL ID 0001 Passwor...

Page 28: ...No 02 Error No 13 Error No 00 Delete all saved error data SET MENU SET MENU Number of the latest error Error No 00 Error No 00 Error No 00 Error No 00 Number of the last error Save up to 20 Do you wa...

Page 29: ...Operating Tuning Operating TUNING OPERATING OPERATING Schedule start time Scheduled operation start time DAY HOUR MINUTE Schedule finish time Scheduled operation finish time Schedule remaining time R...

Page 30: ...100 s 2 s Auto Manual MODE Output mode AUTO MAN AUTO Output operation screen Name Display screen Description Display Initial value Cooling output COOL OUT Select whether to use cooling output USE NOT...

Page 31: ...screen Name Display screen Description Display Initial value RSV MODE RSV MODE RSV MODE NO REV TIME REV WEEK REV No REV Time setting CURRENT TIME Current time Year Month Date Day Hour Minute 0 WEEK RS...

Page 32: ...current T phase current display 20 mA pressure PRES RANGE Max pressure 0 0 10 00 1 50 4 mA pressure Min temperature 0 00 TEMP HI RANGE TEMP RANGE Max temperature 0 0 300 0 300 TEMP LO RANGE Min tempe...

Page 33: ...lue SUCTION SUCTION SUCTION ON OFF OFF COOLING COOLING Forced COOLING REMOTE REMOTE Communication LOCK LOCK LOCK PASSWORD PASSWORD PASSWORD 0000 9999 0000 ID ID Communication ID 1 99 1 Language select...

Page 34: ...creen SV Key to change setting value SET Key to register parameter Key to change parameter Key more cursor RUN RESET Key for starting finishing control operation AT Key for starting finishing AUTO TUN...

Page 35: ...e power is applying to the unit Please check the following things if it does not start control In case the Unit or System has a problem Please refer to Troubleshooting in detail If there is any reserv...

Page 36: ...J for each sensor Set in SENSOR You can set Max and Min temperature limit All temperature settings and control will be conducted within the configured range Set in DISPLAY TEMP RANGE Select whether to...

Page 37: ...automatically stops Auto tuning can be started by pressing AT key during operation or through communication AT LED flashes during auto tuning and turns off when it completes after successful tuning o...

Page 38: ...for OPERATION START or OPERATION FINISH Set in TIME RSV RSV MODE Use this option to start operation after certain period of time based on current time RSV LED flashes when delay time is set In delay t...

Page 39: ...ME WEEK TIME Operation stops Register day and time for WEEK RSV Operation starts in reserved day and time and nishing time is booked Press RUN key to bring up START DAY HOUR MINUTE Current day TUE Day...

Page 40: ...finishing medium filling Control medium filling When there is not enough medium in tank it detects it and start refilling medium after refilling medium it automatically stops filling When user runs c...

Page 41: ...ING is a function that reduces temperature Regardless operation and output mode it stops output of heating band and sets cooling band to 100 You can start and finish Forced COOLING by COOL key or comm...

Page 42: ...ENTER MEDI sensor and MOLD sensor is for control RETURN sensor and ENTER sensor is for monitoring you can check temperature in CONTROL TEMP DISPLAY Select whether to use MEDI sensor and MOLD sensor by...

Page 43: ...essure test is ON it detects pressure fault send alert and register it in ERROR CHECK Display 4 20 mA input according to pressure range entered in CONTROL PRESSURE RANGE Compare the detected pressure...

Page 44: ...d COOLING option REMOTE communication option Please refer to Communication function for more details Block parameter change by using LOCK function User can use controller by key even though LOCK is ON...

Page 45: ...controller or system the BUZZER starts ringing at the time you can OFF the buzzer by removing the cause of error or pressing BUZZER key if the BUZZER key is pressed BUZZER LED flashes and buzzer does...

Page 46: ...not complete within 24 hours Holding state Stop INPUT OPEN 2 Sensor input error POWER ERROR 6 Detect negative phase in power source PUMP DIRECT ACTION OVER 10 PP_D terminal input ON PUMP REVERSE ACTI...

Page 47: ...of FS Sampling Time 1 s Measurement Range 0 00 10 00 Fixed decimal Heating Output Type Voltage Pulse output Over 12 V d c Resolution 0 1 or 16 667 ms of output whichever is larger Cooling Output Type...

Page 48: ...Power terminal earth terminal 2300 V a c for 1 minute Measuring terminal power terminal 2300 V a c for 1 minute Number of inputs 1 contacts Input type 4 20 mA or contact input Sampling cycle 1 s Meas...

Page 49: ...V d c 1 A Measurement accuracy 0 1 or 16 667 ms whichever is larger Number of outputs 1 contact Output type Relay A contact Contact capacity 250 V a c 1 A 30 V d c 1 A Number of inputs 1 contact ON O...

Page 50: ...MA0631K200427 28 Gilpa ro 71beon gil Michuhol gu Incheon Korea TEL 82 1577 1047 http www hynux com MT100...