installation & connection
22_
installation & connection
Connecting to the I/O port box
Connect the Alarm I/O cable to the corresponding port of the port box.
ORANGE: ALARM #1
BROWN: ALARM #2
BLACK: GND
ORANGE: ALARM I/O 1
BROWN: ALARM I/O 2
BLACK: GND
Sensor
Alarm
Alarm-related Connector
J
`
Connect the audio/alarm cable(separately sold) before use.
Color
Function
Description
ORANGE : ALARM I/O 1
BROWN : ALARM I/O 2
ALARM I/O 1,
ALARM I/O 2
These two ports are configurable from the web viewer, as they can be
used as Alarm in or Alarm out
※
Alarm I/O changes can be made through the Webviewer setup.
BLACK
GND
It is a ground terminal.
To connect to an external sensor
To use as an Alarm IN: Connect one of the [ALARM I/O] port and the other terminal to the [GND] port.
Alarm In Wiring Diagram(example)
Sensor
External connection
ALARM I/O 1
ALARM I/O 2
GND
Alarm cable
<If ALARM I/O 1 is set as an input terminal>
Summary of Contents for PNM-C32083RVQ
Page 1: ...NETWORK CAMERA User Manual PNM C32083RVQ PNM C16083RVQ...