Section 2: Installation
Operator Manual
C4000™
(Rev 1)
© Hantle 2010
2.2
Step 6
Using the default combination (contact distributor for default), open the security
Door. This combination should be changed as soon as possible. Refer to section
4.1.5 for instructions on opening or changing the lock.
Step 7
After the anchor nuts are in place, according to the anchor holes on the bottom of
the ATM, secure the anchor bolts snugly. Do not over tighten anchors as it may
distort the vault and cause problems with the door linkage.
END
2.1.3 HARDWARE SETUP
Step 1
Verify the power voltage (115/220V) to be used and set the
appropriate voltage on the power supply. Default will be
115V. The default setting should be 115V
Step 2
Verify that the telephone line to be used for the ATM is in proper working order.
recommends the use of shielded (CAT5) phone line in locations with close proximity
to other appliances.
Step 3
Open the security door and remove any shipping materials and note any warning or
installation instructions. See page 4.1 for assistance.
Use this key (2 included) to
open the top and bottom bezels
Cassette key
(fixed cassette)
Cassette key
(removable cassette)