Hantek HT3003PB User Manual Download Page 6

 

current-limiting protection point is well set. 

2.2.2 Series using of the two adjustable outputs 

2.2.2.1  Press in switch  (13) ( 

position), switch (14) is set to “OUT”

 position 

 

position).  At  this  time,  turn  the  master  voltage  adjustment  (23)  and  the 

slave output voltage tracks strictly the master output voltage,  and the output 

voltage can be up to 60V (voltage between terminal of (10) and (17)). 

2.2.2.2 Before the series connecting, it must be examined if the negative terminals 

of  both  master  and  slave  output  are  connected  to  GND  terminal,  if  they  are,  it 

must  be disconnected,  otherwise short-circuit will  be caused in  the slave  output 

when the two outputs are connected in series. 

2.2.2.3  When  the  two  outputs  are  in  series,  the  output  voltage  is  controlled  by 

master  output,  but  current  adjustment  of  two  outputs  is  still  independent. 

Therefore, attention should be  paid to the position of the C.C. adjustment (6). For 

example,  knob  (6)  is  at  the  position  of  counter-  clockwise  to  end  or  current  of 

slave output excesses current- limiting protection point, at this time the voltage of 

slave  output  will  not  track  the  voltage  of  master.  So  knob  (6)  should  be  rotated 

clockwise to Max, when the two output are in series. 

2.2.2.4 By series connection, if there is power output, proper leads corresponding 

to output power should be used to short connect the negative terminal of master 

output with positive terminal of slave output reliably. Since it is shorted by a switch 

inside the unit, current will pass on the shorted switch when there is power output. 

This will affect the reliability of the unit. 

2.2.3 Parallel using of the two adjustable outputs 

2.2.3.1 Press in switch (13) (       position) as well as switch (14) (        position), 

at  this  time,  the  two  outputs  are  in  parallel,  adjust  voltage  adjustment  (23)  of 

master output the voltage of two ways keep same, and slave output C.C. indicator 

8 lights on. 

2.2.3.2  When  the  two  outputs  are  in  parallel,  the  C.C.  adjustment  (6)  of  slave 

output  does  not  work  When  used  as  C.C.  Supply  simply  adjust  the  C.C. 

adjustment (22)  of master  output,  at this time  output current  of  both master  and 

slave output are controlled by it and are same, output current is up to 6A or10A. 

Reviews: