Hantek HT3003PB User Manual Download Page 3

 

1.2.6 Protection: current-limiting protection 

1.2.7 Indication: Voltmeter & Ammeter or 3-digit volt-(LED) &Amp-(LED) 

a. Volt-indication: (LED)

±

1%

±

2digits 

b. Amp-indication: (LED)

±

2%

±

2digits 

1.3 Fixed output: 

1.3.1 Output voltage: 5V±3 

1.3.2 Output current: 3A 

1.3.3 

Source regulation: ≤1×10

 1mV 

1.3.4 Load regulation: 

≤1×10

 

1.3.5 

Ripple noise: ≤0

 5mV rms 

≤10mVp

-p 

1.3.6 Protection: current limiting short circuit protection 

1.4 Operating ambient 

1.4.1 Operating temperature: 0 to 40°C 

1.4.2 Relative humidity: less than 90 

1.5 Size: 360mm×265mm×165mm 

1.6 Operating time: 8hours continuously 

2. Operation 

2.1 Controls and description of front-panel 

(1) Meter or (LED): indicates master output voltage and current value. 

(4) Meter or (LED): indicates slave output voltage and current value. 

(5) Slave constant voltage adjustment: adjust slave output voltage value. 

(6) Slave constant current adjustment: adjust slave output current value. (adjust 

the current-limiting protection point). 

(7) 

Power  switch:  It  is  set  to  “ON”  state  (the  switch  is  pressed  in),  the  unit  is 

switched on, at this time the constant voltage (C.V.) or constant current (C.C.) 

indicator is on, otherwise, the unit is 

in “OFF”

 state (the switch is sprung out). 

(8) Slave constant current state or two-way parallel state indicator: When slave 

output  is  in  constant  current  state  or  the  two  adjustable  is  in  parallel,  this 

indicator is on. 

(9)  Slave constant voltage  indicator: When slave  output is  in constant  voltage 

state, this indicator is on. 

Reviews: