13.5 Appendix Control motors

 

 

Engine

 

Possible

 

Feedback

 

Notes

 

SolidState 5

 

Yes 

-

 Standard

 

Yes

 

Standard engine with which Spider was developed.

 

Sol

 

Rather not

 

No

 

Old motor 

-

 Preferably replace with a SolidState 5. Sol 

can be used. Connect brown, white and green, and add a 2k2 
resistor to green and grey. 

 

Intelligent 
Motor

 

Yes

 

No

 

More expensive motor and no feedback, not recommended. 

 

RIM Pulse

 

Yes

 

No

 

More expensive motor. Do not connect feedback.

 

RIM Time

 

Yes

 

No

 

More expensive motor. Do not connect feedback.

 

Grey motor

 

Yes

 

Yes

 

Downside to sliders and less power as it is 40 RPM. Preferably 
replace with a SolidState 5. 

 

Black Nedap 
motor

 

Yes

 

Yes

 

Huge disadvantages are the sliders and the fact that this motor 
draws much more current. Preferably replace it with a SolidState 
5. When connecting a Nedap motor, connect red to the green 
connection. 

 

AC motors

 

No

 

No

 

Possible if relay is used, but without feedback. Not recommend-
ed. Not anti

-

spill.

 

DC time

-

controlled 
motors

 

Yes

 

No

 

Not advised by Hanskamp, but possible. Not anti

-

spill.

 

Summary of Contents for Spider

Page 1: ...mber 010 301 000 Date October 2021 Version 3 0 Adjusted instruction manual According to Annex 1 chapter 1 7 4 Machine guideline 2006 42 EG Doetinchem The Netherlands www hanskamp nl en Feeding compute...

Page 2: ...Spider EN Feeding computer Voercomputer F tterungscomputer Logiciel d alimentation Index 2 46 Hanskamp AgroTech B V The Netherlands www hanskamp nl en...

Page 3: ...e Hanskamp shall not be liable for errors or faults in this manual The recommendations are meant to serve as guidelines All instructions pictures and specifications in this manual are based on the lat...

Page 4: ...UTP cable with network connectors 16 3 2 4 Assembly L port and or T port to Spider 17 3 3 Installation in the milking parlour 19 3 3 1 Connecting the limit switch 19 3 3 2 Examples of installation in...

Page 5: ...ng components 35 9 1 Replacing PCB 35 9 2 Replacing Antenna 35 9 3 Replacing CarrierBoard 35 10 Extra information 36 11 Declaration 37 12 Notifications FAQ 38 12 1 Notifications 38 12 2 FAQ 39 13 Appe...

Page 6: ...n be connected to each exit e g a motor that dispenses concentrate The electronics in a Spider box are capable of controlling four feeding stations each with four different types of feed Using one con...

Page 7: ...f your Spider You must make sure that you and anyone else who is going to operate maintain or work in the vicinity of the Spider knows all the related safety information in this manual You are the key...

Page 8: ...all parts of the Spider meet the local rules and regulations Replace any damaged electrical lines conduits switches and components immediately Isolate the electrical power supply before you open the S...

Page 9: ...witch off the electrical power supply by pulling the plug out of the power point and secure the plug before you clean or do maintenance on the Spider Wear protective clothing and safety goggles when y...

Page 10: ...rotective foil on the inside to prevent damage The Spider shall also be stored in this way See fig 1 for supply specifications Please note Always move the box carefully Please note When opening the pa...

Page 11: ...g computer Voercomputer F tterungscomputer Logiciel d alimentation Index 11 46 Hanskamp AgroTech B V The Netherlands www hanskamp nl en 3 1 Construction overview Spider User IP generated by router see...

Page 12: ...on use the case mounting plate art no 004 247 000 Install the SpiderServer on one side and the PowerUnit art no 002 812 000 on the other 3 Install the SpiderAntenna on the feed trough and run the cabl...

Page 13: ...Use the ethernet LAN ports on the CarrierBoard and SpiderPCB The ethernet LAN ports on the CarrierBoard serve as a switch Do NOT connect the SpiderPCB or SpiderClient to the WAN port on the left fig...

Page 14: ...EN Feeding computer Voercomputer F tterungscomputer Logiciel d alimentation Index 14 46 Hanskamp AgroTech B V The Netherlands www hanskamp nl en 3 2 1 Overview SpiderPCB Output gates Detection Article...

Page 15: ...ure 10 Leg recognition ensure that the EWA Antenna Transformer unit art no 005 175 000 is located under the feed trough mounting plate and that the Antenna cannot come into contact with the feed troug...

Page 16: ...on a feeding station The SpiderServer and SpiderClient must not be more than 100 meters apart Use a data cable art no 005 109 000 to connect the SpiderClient to the SpiderServer Cut the SF UTP cable t...

Page 17: ...www hanskamp nl en 3 2 4 Assembly L port and or T port to Spider L port connection diagram control unit art no 002 480 001 If the switch works the other way around rotate it by 180 degrees 12 Green Br...

Page 18: ...x0 5 LiYY 15 mtr Direction Spider Detection Brown Pink Yellow White Grey Green Green White Brown Cut off yellow wire 001 593 000 cable LiYY 8x0 34 direction Spider Gate L port cable 001 100 000 Cautio...

Page 19: ...l The limit switch deactivates the Antennas during the switch This prevents feeding until all the cows are in the correct position The below example shows the correct set up for a 2x8 milking parlour...

Page 20: ...re that the animal s transponder is within the boundaries of the Antenna Figure 16 17 Ear recognition Use the mounting kit art no 007 535 000 for installation on the MultiFrame 40 50 60 70 Because the...

Page 21: ...terface If you experience problems with logging in refer to chapter 12 2 FAQ Log in 4 1 1 Signing in on a PC or via a home network optional It is also possible to connect a PC or laptop with a cable C...

Page 22: ...shown in figure 3 Select Add if no SpiderPCB is displayed or if an additional one needs to be added Then the next screen will open figure 2 Select the number of feeding stations you want to add as wel...

Page 23: ...will remain open Disabled The closing gate is disabled No closing gate Click Select Front gate no The exit number which the T port is connected to Note this only applies to the FeedStation Walk Throu...

Page 24: ...ow 4 3 1 Tag tuning Tag tuning is used for automatic programming of the SpiderPCB s RFID settings every SpiderPCB must be configured separately With tag tuning all transponder settings are set correct...

Page 25: ...will be reported and the old settings will be restored You can then manually try to read the tag by changing the SpiderPCB parameters See chapter 4 3 4 on how to change SpiderPCB parameters 4 3 2 Set...

Page 26: ...se and decrease this value in steps of 500 to find the best setting for your situation 30002 RFID Multiplextime This is the time frame within which the Antenna is active and ready to read the tag Only...

Page 27: ...to light up red and flash green when transponder is recognized 3 Loosen the adjusting screw in the EWA until the green LED switches off 4 Hold the transponder facing outwards approx 20 cm above the g...

Page 28: ...ation the animal has no more feed credit or has not been recognised for a while Yellow continuous Only applicable in milking parlour If the limit switch is activated continuously the yellow LED will r...

Page 29: ...o the internet the update can be performed by means of a USB stick This USB stick is placed in the Spider on the CarrierBoard Download the software via hanskamp nl en brochures downloads search for Sp...

Page 30: ...layed when running the setup Choose the users who will be authorised to use the program and click Next After installation the screen can be closed with Close If the setup was launched on a computer wh...

Page 31: ...of the cycle and the motor will stop Cycle This is the time allowed for the motor to dispense one portion A second actuation is only possible after the cycle has been completed This means that the cy...

Page 32: ...icking Deselecting removing from selection without clicking Select a number of animals then click on Group input to perform the desired action Parlour monitor Live monitor The animals that have been r...

Page 33: ...nd the headers A B C etc Note Any animal data on the first line will not be imported The order of notation is not important the fields can be allocated later See the image below for an example of the...

Page 34: ...amount per visit 6 No permission to feed as she has eaten the maximum feed amount during the previous visit there must be a two hour time difference inbetween visits 7 Normal visit animal is eating m...

Page 35: ...values noted in step 1 If the values are unknown configure them now Parameters Set default values Tag tuning see chapter 4 3 11 Test all inputs and outputs 9 2 Replacing Antenna 1 Disconnect the Anten...

Page 36: ...have been tested However in the event of malfunctions Hanskamp AgroTech B V cannot be held liable for consequential damages No Release date Chapter s Note 1 0 12 2018 First edition 1 1 06 2019 All Up...

Page 37: ...om Hanskamp AgroTech B V to which this declaration pertains does meet the stipulations of the following directive s Machine Directive 2006 42 EC and completely or partially meets the following essenti...

Page 38: ...or Connect the Motor properly and or try another exit on the PCB see chapter 4 2 Motor error no feedback Motor has no feedback Connection error Motor takes to much time for rotation Change Motor setti...

Page 39: ...er active There is no contact with wifi dongle Problem with user device laptop phone or tablet Turn wifi on device off and on again When wifi is not connectable forget wifi and search again Restart Sp...

Page 40: ...with fastening material for Spider enclosure 1 005 107 000 Communication cable between CarrierBoard and SpiderPCB in SpiderServer 1 005 110 000 SpiderPCB FSCU Controlboard 16 feeders 16 readers 1 005...

Page 41: ...Description of parts SpiderClient art no 005 115 000 Article number Description Number 001 347 000 Tap bolt M3x6 a2 cross recessed DIN7958 8 005 102 000 Spider enclosure with cutout 1 005 103 000 Set...

Page 42: ...iderAntenna 134 2 kHz red 005 150 500 SpiderAntenna 134 2 kHz orange Loose parts 001 509 000 Mushroom head square neck bolt M8x60 DIN603 4 001 769 000 Prevailing torque type hexagon nut M8 a2 DIN985 c...

Page 43: ...059 000 Nylon universal plug quattro SX 8mm ve100 1 011 090 000 Gripseal bag 80x120x0 05mm 1 Article number Description Number 001 043 100 Hexagon nut M8 a2 DIN439 4 001 347 000 Tap bolt M3x6 a2 cross...

Page 44: ...re expensive motor and no feedback not recommended RIM Pulse Yes No More expensive motor Do not connect feedback RIM Time Yes No More expensive motor Do not connect feedback Grey motor Yes Yes Downsid...

Page 45: ...is hollow remaining cables can be tied up inside it preventing the animals from reaching them Spider FieldTester 134 2 kHz art no 005 130 000 can be used to adjust the Antenna field for an EWA Antenna...

Page 46: ...alimentation Index 46 46 Hanskamp AgroTech B V The Netherlands www hanskamp nl en Hanskamp AgroTech B V Broekstraat 17 7009 ZB Doetinchem The Netherlands Tel 31 0 314 393 797 Fax 31 0 314 393 826 www...

Reviews: