Assembly
Page EN-12
Assembly
Space requirements
(a)
(b)
(c)
(d)
(e)
Important units:
Dimensions
in cm
(a) Minimum distance
between stovetop and
lower edge of exhaust
hood (1)
65–75
(b) Height of exhaust
hood (1)
39
(c) Height of the entire flue
screen, (2) and (3)
40(50)–77
(d) Height of the entire
appliance, (1), (2) and (3)
79(89)–118
(e) Space required above
the stovetop
144(154)–191
The images and tables show the minimum
distances that must be complied with and how
much leeway you have while installing.
The figures in brackets refer to circulation air
operation; the ventilation slits must be kept
clear.
Attachment dimensions
(g)
(f)
(i)
(j)
(h)
Calculating drill holes:
Dimensions
in cm
(f) Height of the safety screws
(12) for exhaust hood (1)
8
(g) Height of the attachment
screws (11) for exhaust
hood (1)
35.5
(h) Distance between the
safety screws (12) for
exhaust hood (1)
35
(i) Distance between the
attachment screws (11) for
exhaust hood (1)
35
(i) Distance between the
attachment screws (10) for
the wall mount (2) for the
upper flue screen (6)
10.5