Start-up
Page GB-18
Space required according to the
appliance dimensions
Modell SC-70W:
A:
430 mm
B:
690 mm
C:
100 mm
D:
470 mm
E:
875 mm
F:
100 mm
G:
50 mm
H:
130 °
I:
710 mm
Modell SC-98W:
A:
470 mm
B:
830 mm
C:
100 mm
D:
472 mm
E:
915 mm
F:
100 mm
G:
50 mm
H:
130 °
I:
770 mm
Modell SC-130W:
A:
540mm
B:
845 mm
C:
100 mm
D:
540 mm
E:
1050 mm
F:
100 mm
G:
50 mm
H:
130 °
I:
880 mm
– To prevent the formation of a flammable
gas-air mixture in the event of a leakage
in the refrigeration circuit, the installation
space must have a minimum size of 2.2 m³.
– The appliance must only be placed on a
level and firm surface. The surface must be
strong enough to support the appliance’s
weight when fully laden.
– Suitable locations are dry, well-ventilated
areas that are cool if possible.
– Unsuitable locations are ones with direct
sunlight or which are directly next to an
oven, hob or radiator.
– The following minimum distances must be
maintained:
– from electrical hobs: 5 cm
– from oil and coal burning stoves: 30cm
– from other cooling appliances: 5 cm
– from washing machines/dishwashers: 5 cm
– If you would like to reduce these distances,
you can fit an insulation plate between the
appliances.
– If underfloor heating is installed at the set-
up location, place the cooling appliance on
an insulation plate made from solid material.
D
E
F
G
G
I
H
C
A
B