Performance parameters/Installation preparation
circuit breaker with a rated current of 16 A (motor circuit breaker) downstream of the
Residual Current protective Device.
Recommended Type C or D circuit breaker (motor circuit breaker)
Hot tubs with two massage motors:
3× 16 A/C or D
Hot tubs with three massage motors:
3× 20 A/C or D
!!!THE HOT TUB MUST ONLY BE CONNECTED BY A PERSON WITH PROFESSIONAL
ELECTRICAL QUALIFICATION IN ACCORDANCE WITH DECREE NO. 50/1978 COLL.!!!
1.2
Performance parameters of PLUG & PLAY hot tubs
Performance parameters
rated voltage:
single phase 1× 230 V 60 Hz*
maximum working current:
1× 16 A
voltage resistance:
1 250 V/min. without breakdown
insulation resistance:
>= 1 M Ω
water resistance (cover):
IPX5
protection against electric shock:
first stage
Load capacity
heating:
1× 230 V/2 kW/13.6 A
ozone:
230 V/50 Hz /80 mA
pump 1/2:
2.2 kW
total input power (depending on type of hot tub):
2.7 kW / h
protection class:
I.
lighting:
LED 12 V AC/10 W
moisture resistant speakers:
according to equipment
2
Hot tub installation preparation
Inspect the hot tub prior to installation! If any part is damaged or missing,
contact the seller immediately! Make sure that all components are in
accordance with your order. Check the hot tub before each use. In the event
of damage, do not use the hot tub!