GB
Settings:
Set water running time (normal function) (page 15)
The water running time can be set individually
(running time approx. 1 - 10 s)
Short Off (page 16)
Temporary interruption of the water fl ow (pause).
For undisturbed cleaning of the tap, shower, etc.
Stops automatically or at any time when button is pressed.
(after 2 min.)
12/24-hour forced fl ushing (page 17)
Flushing 12/24 hours after last use.
Continuous On: Initiate (page 18)
Permanent water fl ow. For fi lling the washbasin,
containers, etc.
Stops automatically or at any time when button is pressed.
(after max. 2 min.)
Continuous On: Programme water running time (page 19)
“Continuous On” setting (0,5-20 min)
Manual adjustment of the sensor range (page 20)
Manual sensor range adjustment to the wash-basin.
Ensures optimum comfort and prevents that the tap fi ttingruns
on its own.
Fault - Cause - Remedy
Malfunction/fault
Possible cause
Remedy
No water is fl owing
• Black object
• Faulty solenoid
• Faulty electronics
Sensor does not recognise black
Replace solenoid
Replace electronic
Sensor is fl ashing
• Clogged/dirty sensor
• Refl ection (autom. water stop after
1 min. continuous fl ow)
Clean/strip sensor
Remove object
or “Autoset”
Water fl ows continuously
• Refl ection in washbasin
• Power failure while water is fl owing
• Faulty solenoid/diaphragms
• Dirty sensor
“Autoset” or Manual adjustment of the sensor range
Restore the power supply
Replace solenoid
Clean sensor
Tap switches independently
• Refl ection in washbasin
“Autoset” or Manual adjustment of the sensor range
Insuffi cient water fl ow
• Insuffi cient supply pressure
• Clogged perlator
• Faulty non-return valves
Check supply line
Clean/replace perlator
Replace non-return valves
Flashing when water is fl owing
• Discharged battery
Replace battery
Tap is dripping
• Dirty diaphragms
Clean/replace solenoid
Incorrect water temperature
• Problem with water supply
Check water supply
Electronic does not react
• Battery discharged/faulty
• Battery incorrectly inserted
• Faulty button
• Incorrect operation
Replace battery
Insert battery correctly
Replace electronics
“Autoset”