Valid from: 15.02.2021 / Source: VAM-UM-00551-EN-04
Despite careful checking, we cannot exclude the possibility of errors in this document and we accept no liability for the information it contains.
Page 19
The burst pressure protection breaks at a pressure of over 400 bar. Stainless steel volume flow
meters are designed for an operating pressure of up to 350 bar and a safety factor of 3:1.
Burst pressure protection HANSA-FLEX article number:
K-MEP2470
Figure 11: Power meter with burst pressure protection
Figure 12: Locking screw
Figure 13: (Hex nut) screw-in part with safety disc
1.
Remove the locking screw from the power meter (
see Figure 11/ 12)
2.
Remove the screw-in part from the locking screw
3.
The safety disc is located in the bottom section of the screw-in part
(see Figure 13)
Undo
the hex nut and replace the defective safety disc (P2470) Art. No. K-MEP2470. The safety
disc deforms when the hex nut is tightened.
Make sure that the high-pressure seal fits correctly when it is remounted!