4
English
Assembly
(see page 34)
Safety Notes
Wear personal protective equipment (PPE) (safety shoes, gloves, etc.)
The hot and cold supplies must be of equal pressures.
Electrical connection
The current version of the applicable regulations from VDE, local authorities and
utility companies must be observed for electric installation work.
The installation and test work must be performed by an authorized electrician
under consideration of DIN VDE 0100 part 701 / IEC 60364-7-701.
The system must be protected via a leakage current protective device (RCD/ FI)
with a measurement difference current of ≤ 30 mA.
The proper function of this protective device must be checked at regular
intervals.
The ambient temperature must not be higher than 50ºC.
Installation Instructions
• Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
• The pipes and the fixture must be installed, flushed and tested as per the
applicable standards.
• The plumbing codes applicable in the respective countries must be observed.
• During installation of the product by qualified trained personnel, make sure that
the entire fastening surface is even and smooth (no protruding seams or tile
offset), that the finish of the wall is suitable to apply the product and has no
weak points.
• Any work may only be carried out in a de-energized state.
• Pull the connecting cable #10504118 provided into the empty conduit (EN 20)
by means of a cable retractor.
• Only standardized materials may be used for the installation.
• All components must remain accessible.
• No easily inflammable material is allowed in the immediate vicinity.
• The installation location of the iBox control must be accessible at any time and
must lie outside areas 0 and 1. The installation length of water pipes to the
consumers should be as short as possible (piping length < 7 m).
transformer
The power supply unit must be installed in a flush socket > Ø 60 mm (deep
version). This flush socket is connected with the installation area for the iBox
control via an empty conduit EN 20.
The voltage supply from the 12 V DC SELV must only be fed via the included
transformer type 30335810. The transformer must be installed safe from
outside contact outside the zones 0, 1 and 2 in a flush-type box to be provided
by the customer.
The mains voltage of 100 - 240 V AC 50 - 60 Hz must be supplied on-site via
an isolating device (e.g. an all-pole switch acc. to EN 60335-1 clause 24.3)
and via a residual current device (RCD / FI) with a rated difference current
≤ 30 mA.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,13 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 60°C
Recommended hot water temp.:
45°C
Connections:
Rp 1/2
Type plate:
see page 37
The product is exclusively designed for drinking water!
Thermal disinfection
Thermal disinfection pursuant to process sheet DVGW W 551 (≥ 70°C / > 3 min)
must only be carried out by qualified personnel.
Assembly basic kit RainPad
(see page 35)
Fig. 6
Plaster the installed and tested basic components, or cover with panelling if
installed on the exterior of the wall.
Fig. 7
After the plastered wall surface is dry seal the gap with silicone (free from acetic
acid!) between wall and plastic housing of the iBox.
Fig. 8
Apply PCI-Lastogum or similar sealing compound on the wall in accordance with
manufacturers indications.
Fig. 9
Put gasket over the plastic housing of the iBox.
The gasket is not suitable for hot glue.
Repair
Only by Hansgrohe trained personnel or persons or companies appointed by
Hansgrohe.
Disposal of waste batteries and old Electrical &
Electronic Equipment
(applicable in the European Union
and other European countries with separate collection
systems).
This symbol on the battery, the product or the packaging indicates that the battery
or the product shall not be treated as household waste. By ensuring the battery or
product are disposed of correctly, you will help prevent potentially negative
consequences for the environment and human health. The recycling of the
materials will help to conserve natural resources. To ensure that the battery or
product will be treated properly, hand over the product at end-of-life to the applica-
ble collection point for the recycling of batteries, electrical and electronic
equipment. For more detailed information about recycling of this product or
battery, please contact your local Civic Office, your household waste disposal
service or the shop where you purchased the product.
Symbol description
Do not use silicone containing acetic acid!
Dimensions
(see page 36)
Flow diagram
(see page 33)
Spare parts
(see page 37)
Installation example
(see page 32)
i
Summary of Contents for RainPad iBox Control 15853180
Page 35: ...35 PCI Lastogum max min min 55 max min max 83 r 100 6 7 8 9...
Page 38: ...38...
Page 39: ...39...