Assembly see page 31
English
Symbol description
Do not use silicone containing acetic acid!
Operation
(see page 35)
Cleaning
see enclosed brochure
Dimensions
(see page 36)
Flow diagram
(see page 37)
Spare parts
(see page 38)
Maintenance
(see page 40)
The check valves must be checked regularly
according to DIN EN 1717 in accordance
with national or regional regulations (at least
once a year).
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
The hot and cold supplies must be of equal pres-
sures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
• The diverter (type HC) installed in the bath mixer is
designed as an anti-retraction device. For this reason,
the lower edge of the diverter must be at least 25 mm
above the highest possible dirty water level.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 70°C
Recommended hot water temp.:
65°C
Thermal disinfection:
max. 70°C / 4 min
• Safety against backflow
• The product is exclusively designed for drinking water!
Fault
Cause
Remedy
Insufficient water
-
check valve hasn't moved back
-
Exchange check valves
-
Shower filter seal dirty
-
Clean filter seal between shower
and hose
Mixer stiff
-
Cartridge defective, calcified
-
Exchange cartridge
Mixer dripping
-
Cartridge defective
-
Exchange cartridge
Hot water temperature too low
-
Hot water limiter incorrectly set
-
Set hot water limiter
Instantaneous heater didn’t work
-
Flow limiter in handshower isn’t
removed
-
Remove flow limiter
-
Shower filter seal dirty
-
Clean filter seal between shower
and hose
-
check valve hasn't moved back
-
Exchange check valves
Adjustment
(see page 34)
To adjust the hot water limiter. Using a hot
water limiter in combination with a continu-
ous flow water heater is not recommended.
4
Summary of Contents for Novus 71040000
Page 14: ...31 35 36 37 38 40 DIN EN 1717 HC 25 1 0 1 0 5 1 6 1 10 bar 147 PSI 70 C 65 C 70 C 4 34 14...
Page 28: ...31 35 36 37 38 40 DIN EN 1717 HC 25 1 0 1 0 5 1 6 1 10 bar 147 PSI 70 C 65 C 70 C 4 34 28...
Page 30: ...31 35 36 37 38 40 DIN EN 1717 HC 25 1 0 5 0 1 1 6 PSI 147 10 1 70 C 65 C 4 70 C 34 30...
Page 33: ...33 Montage 17 Nm 1 2 SW 22 mm 2 min SW 22 mm 2 Nm 3 4 Novus 71041000 71061000...
Page 34: ...34 Justierung Justierung 2 1 3 4 5 6 7 60 C 10 C 0 3 MPa 0 3 0 3...