6
7
English
Attention!
The fitting must be installed, flushed and
tested after the valid norms.
Operation
The mixer is actuated by lifting the lever head.
Swivel to the left = hot water, swivel to the right =
cold water.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure: 0,1 - 0,5 MPa
Test pressure:
1,6 MPa
Hot water temperature:
max. 80° C
Recommended hot water temp.: 65° C
Rate of flow 0,3 MPa:
approx. 32 l/min
Test certificate
14615XXX/15615XXX/
31655XXX/32655XXX/
WRAS
32675XXX/33655XXX:
0209009
Hansgrohe single lever mixers can be used together
with hydraulically and thermically controlled
continuous flow heaters if the flow pressure is at
least 0,15 MPa.
To adjust the hot water limiter on single lever mixers,
please see page 14.
No adjustment is necessary when using a continuous
flow water heater.
Spare parts
(see page 3)
1
handle Metropol
14092XXX
1.1 screw cover
96338000
2
handle Mondial
15092XXX
3
handle Metris
31092000
4
handle Sportive
32091000
4.1 screw cover
94191000
5
handle Talis S
32092000
6
handle Talis E
33091000
7
handle Fcus S
31793000
8
handle Focus E
31791000
9
escutcheon
96452XXX
10 flange
95010XXX
11 fixing screw
96454000
12 sub plate
96447000
13 nut
95007000
14 locking screw
96059000
15 seal
95008000
16 noise reduction
94073000
17 cartridge cpl.
92730000
18 extension set 25 mm
13595000
19 extension set 22 mm
13596XXX
XXX
= Colors
000 chrome plated
090 chrome plated/gold plated
810 satinox
®
880 satin chrome
Fault
Cause
Remedy
Mixer stiff
- Cartridge defective, calcified
- Exchange cartridge
Mixer dripping
- Cartridge defective
Sedimentation
- Exchange cartridge
Diverter not operating
- Water pressure to low
- Diverter defective
- Increase water pressure
- Exchange diverter
Hot water temperature too low
No cold water
Instantaneous water heater
starts up when cold water is
selected
- Hot water limiter incorrectly set
- Crossflow
- Set hot water limiter
- Exchange seal (
15
),
o-ring seal (
15.1
)